Homepage  
Search
find:
search for:
   
 
Site Navigation
News / Publications
Jobs
Service
   Add this page to Google Bookmarks
   Add this page to Mister Wong
   Add this page to del.icio.us
 
   Metal Sales Mfg. Corp.  Metal Solutions  

Metal Solutions Page - 5

 

 

BUILDING PRODUCTS
sol05a.JPG (7408 bytes)

sol05b.JPG (6339 bytes)

  • Exposed Fastened Metal Building Panel
  • 36" Panel Coverage
  • Trapezoidal Rib on 12" Centers
  • 1 1/8" Rib Height
  • Gauges: 26 GA and 24 GA Standard, 22 GA Optional
  • Minimum Roof Slope: 1 : 12
  • Applies Over Open Framing or Solid Substrate
  • Finishes: MS Colorfast 25® and Bare Galvalume™

Testing:

  1. UL 580, Class 90 Wind Uplift for Span-Line 36 only construction number 186
  2. Texas Windstorm Approved



sol05c.JPG (7123 bytes)

  • Exposed Fastened Metal Building Panel
  • 36" Panel Coverage
  • Trapezoidal Rib on 12" Centers
  • 1 1/4" Rib Height
  • Gauges: 26 GA and 24 GA Standard, 22 GA Optional
  • Minimum Roof Slope: 1 : 12
  • Applies Over Open Framing or Solid Substrate
  • Finishes: MS Colorfast 25® and Bare Galvalume™

Testing:

  1. UL 580, Class 90 Wind Uplift
  2. Texas Windstorm Approved

sol05d.JPG (5978 bytes)

  • Exposed Fastened Metal Building Panel *
  • 36" Panel Coverage
  • Trapezoidal Rib on 6" Centers
  • 3/4" Rib Height
  • Gauges: 26 GA and 24 GA Standard, 22 GA Optional
  • Minimum Roof Slope: 1 : 12
  • Applies Over Opening Framing or Solid Substrate
  • Finishes: MS Colorfast 25® and Bare Galvalume™

Testing:

  1. UL 580, Class 90 Wind Uplift
  2. Texas Windstorm Approved

sol05e.JPG (5393 bytes)

  • Exposed Fastened Industrial Panel
  • 32" Panel Coverage
  • Trapezoidal Rib on 4 9/16" Centers
  • 1 3/8" Rib Height
  • Gauges:  26 GA and 24 GA Standard, 22 GA Optional
  • Minimum Roof Slope: 1 : 12
  • Applies Over Open Framing or Solid Substrate
  • Finishes: MS Colorfast 25® and Bare Galvalume™ 

Testing:

  1. UL 580, Class 90 Wind Uplift
  2. Texas Windstorm Approved


sol05f.JPG (4808 bytes)

  • Exposed Fastened, Low Profile Panel
  • 36" Panel Coverage
  • Trapezoidal Rib on 9" Centers
  • 5/8" Rib Height
  • Gauges:  26 GA Standard and 24 GA Optional
  • Minimum Roof Slope: 3 : 12
  • Applies Over Open Framing or Solid Substrate
  • Finishes: MS Colorfast 25® and Bare Galvalume™

Testing:

  1. Texas Windstorm Approved
  2. Dade County, FL Approved

sol05g.JPG (4811 bytes)

  • Exposed Fastened, Low Profile Panel
  • 36" Panel Coverage
  • Trapezoidal Rib on 9" Centers
  • 3/4" Bell Top Trapezoidal Rib Height
  • Gauges: 26 GA Standard
  • Minimum Roof Slope: 3 : 12
  • Applies Over Open Framing or Solid Substrate
  • Finishes: MS Colorfast 25® and Bare Galvalume™

Testing:

  1. Texas Windstorm Approved

sol05h.JPG (4919 bytes)

  • Exposed Fastened Panel
  • 24" Panel Coverage
  • Trapezoidal Rib on 8" Centers
  • 13/16" Rib Height
  • Gauges: 29 GA and 26 GA Standard
  • Minimum Roof Slope: 3 : 12
  • Applies Over Open Framing or Solid Substrate
  • Finishes: MS Colorfast 25® and Bare Galvalume™

 

Request for Information / Request a Catalog from Metal Sales Mfg. Corp.
 
 
 
To request more information from Metal Sales Mfg. Corp., please complete the form below.
 
*Name:    
*Email:    
Company:    
*Company type:    
Phone:    
*Address:    
*Request:    
    (* = Mandatory field) 
Please add me to the mailing list for the free monthly e-Newsletter AECnews.  
     






Printable version Bookmark this page Notify a colleague or friend about this pageHome | Terms of Use | Privacy Statement | Link to AECinfo
AECinfo is a member of Docu Group, the world's largest building products information network.



Copyright © 1996–2008 AECinfo.com