Metal Sales Mfg. Corp. Metal Solutions Metal Solutions Page - 5
BUILDING PRODUCTS


- Exposed Fastened Metal Building Panel
- 36" Panel Coverage
- Trapezoidal Rib on 12" Centers
- 1 1/8" Rib Height
- Gauges: 26 GA and 24 GA Standard, 22 GA Optional
- Minimum Roof Slope: 1 : 12
- Applies Over Open Framing or Solid Substrate
- Finishes: MS Colorfast 25® and Bare Galvalume™
Testing:
- UL 580, Class 90 Wind Uplift for Span-Line 36 only construction number 186
- Texas Windstorm Approved

- Exposed Fastened Metal Building Panel
- 36" Panel Coverage
- Trapezoidal Rib on 12" Centers
- 1 1/4" Rib Height
- Gauges: 26 GA and 24 GA Standard, 22 GA Optional
- Minimum Roof Slope: 1 : 12
- Applies Over Open Framing or Solid Substrate
- Finishes: MS Colorfast 25® and Bare Galvalume™
Testing:
- UL 580, Class 90 Wind Uplift
- Texas Windstorm Approved

- Exposed Fastened Metal Building Panel *
- 36" Panel Coverage
- Trapezoidal Rib on 6" Centers
- 3/4" Rib Height
- Gauges: 26 GA and 24 GA Standard, 22 GA Optional
- Minimum Roof Slope: 1 : 12
- Applies Over Opening Framing or Solid Substrate
- Finishes: MS Colorfast 25® and Bare Galvalume™
Testing:
- UL 580, Class 90 Wind Uplift
- Texas Windstorm Approved

- Exposed Fastened Industrial Panel
- 32" Panel Coverage
- Trapezoidal Rib on 4 9/16" Centers
- 1 3/8" Rib Height
- Gauges: 26 GA and 24 GA Standard, 22 GA Optional
- Minimum Roof Slope: 1 : 12
- Applies Over Open Framing or Solid Substrate
- Finishes: MS Colorfast 25® and Bare Galvalume™
Testing:
- UL 580, Class 90 Wind Uplift
- Texas Windstorm Approved

- Exposed Fastened, Low Profile Panel
- 36" Panel Coverage
- Trapezoidal Rib on 9" Centers
- 5/8" Rib Height
- Gauges: 26 GA Standard and 24 GA Optional
- Minimum Roof Slope: 3 : 12
- Applies Over Open Framing or Solid Substrate
- Finishes: MS Colorfast 25® and Bare Galvalume™
Testing:
- Texas Windstorm Approved
- Dade County, FL Approved

- Exposed Fastened, Low Profile Panel
- 36" Panel Coverage
- Trapezoidal Rib on 9" Centers
- 3/4" Bell Top Trapezoidal Rib Height
- Gauges: 26 GA Standard
- Minimum Roof Slope: 3 : 12
- Applies Over Open Framing or Solid Substrate
- Finishes: MS Colorfast 25® and Bare Galvalume™
Testing:
- Texas Windstorm Approved

- Exposed Fastened Panel
- 24" Panel Coverage
- Trapezoidal Rib on 8" Centers
- 13/16" Rib Height
- Gauges: 29 GA and 26 GA Standard
- Minimum Roof Slope: 3 : 12
- Applies Over Open Framing or Solid Substrate
- Finishes: MS Colorfast 25® and Bare Galvalume™
|
Copyright © 19962008 AECinfo.com
|
|