SPECIFICATIONS

Greige Base P/1310

Fabric Construction _______ Tufted, Patterned Cut Pile
Fiber Type _______ Milliken Certified Nylon Type 6, 6 Staple
Soil Protectant _______ MilliGuard®SP
Mold/Midew Control _______ BioCare®
Dye Method _______ Millitron®
Tufted Face Weight _______ 32 Oz. Square Yard(1085 gm/m2)
Finished Face Weight _______ 30 Oz. Square Yard(1018 gm/m2)
Tufting Gauge (Pitch) _______ 1/8 Gauge
Yarn Ply _______ 2 Ply
Stitches Per Inch (Rows) _______ 11.4 Stitches/Inch (44.7 Stitches/10 cm)
Tufting Density _______ 91 Tufts/Square Inch (1411/100 cm2)
Density Factor _______ 307,800
Finished Pile Height _______ Nominal .32” Sheared(10.85 mm)
Total Thickness _______ Nominal .42” Sheared(14.25 mm)
Total Weight _______ 64 Oz./Square Yard(2171 gm/m2)
Primary Backing _______ Synthetic Non-woven
Secondary Backing _______ Synthetic Actionbac®
Width _______ 13’ 6”(4.12 m)
Mold/Midew Control Effectiveness _______ Validated By: AATCC 174 (3 Part Test)
Radiant Panel (ASTM-E-648 Class 1) _______ >.45 Watts/Centimeter Square
NBS Smoke Density (NFPD-258-T or ASTM-E-662) _______ <450 Flaming & Non-Flaming
Methenamine Tablet Test (DOC-FF-1) _______ Self Extinguishing
CRI Indoor Air Quality _______ Product Type: 06112860
Xenon Light Fastness _______ 4.5 Min. @ 60 Hrs. 3.5 Min. @ 120 Hrs.
(4.0 Minimum @ 40 Hours Industry Standard)
Ozone Fastness _______ 3 Cycles(Industry Standard 2 Cycles)
Step Scuff _______ 100 Cycles (No End Point Reached)
Traffic Lane Simulator _______ 20 Hours
Wira Abrasion Test _______ 100,000 Cycles (No End Point Reached)
Appearance Retention (BS-6659, Scale 1-5) _______ Class 3 (Moderate to Heavy)
Static Electricity (AATCC-134) 20% R. H., 70 F _______ <3.0 KV
Recommended Maintenance _______ MilliCare® Environmental Services
Recommended Traffic _______ Recommended for Hotel Rooms and Suites

 

Specifications are subject to normal manufacturing tolerances
and may be changed without prior notice.
Copies of actual test results are available upon request.

Applicable Milliken Warranties include:
Milliken 5 Year Wear, Hotel Guest Rooms Only
Milliken 2 Year Latent Defect

 


Specification Date: 03/18/98 Supersedes: NEW

Request for Information / Request a Catalog from Milliken & Co
 
 
 
To request more information from Milliken & Co, please complete the form below.
 
*Name:    
*Email:    
Company:    
*Company type:    
Phone:    
*Address:    
*Request:    
    (* = Mandatory field) 
Please add me to the mailing list for the free monthly e-Newsletter AECnews.  
     






Printable version Bookmark this page Notify a colleague or friend about this pageHome | Terms of Use | Privacy Statement | Link to AECinfo
AECinfo is a member of Docu Group, the world's largest building products information network.



Copyright © 1996–2009 AECinfo.com