How much do I need?

To determine the quantity of Nixalite® needed, carefully measure the depth and length of the surface. Take these dimensions and refer to the Surface Depth Specification Charts shown below. The total of Nixalite® required (T), is found by multiplying the row or rows required for the surface depth (RR) by the length of the surface (L). (RR x L=T)


Single Exposed
Buildings & Window ledges etc. 

Surface Depth

Rows

Inches

Centimeters

Required

0-2

0 - 5.1

1/2* row

2-4

5.2 - 10.2

1 row**

4 1/4 - 6

10.3 - 15.3

1 1/2 rows

6 1/4 - 9

15.4 - 22.9

2 rows

9 1/4 - 14

23.0 - 35.6

3 rows

14 1/4 - 9

35.7 - 48.3

4 rows

19 1/4 - 24

48.4 - 61.0

5 rows

24 1/4 - 29

61.1 - 73.7

6 rows

29 1/4 - 34

73.8 - 86.4

7 rows

34 1/4 - 39

86.5 - 99.1

8 rows

39 1/4 - 44

99.2 - 111.8

9 rows

44 1/4 - 49

111.9 - 124.5

10 rows

 

Double Exposed
Parapets, Beams, Pole Signs, etc.

Surface Depth

Rows

Inches

Centimeters

Required

0-3 1/2

0 - 8.9

1** row

3 3/4 - 5

9.0 - 12.7

1 1/2* rows

5 1/4 - 7 1/2

12.8 - 19.1

2 rows

7 3/4 - 12 1/2

19.2 - 31.8

3 rows

12 3/4 - 17 1/2

31.9 - 44.5

4 rows

17 3/4 - 22 1/2

44.6 - 57.2

5 rows

22 3/4 - 27 1/2

57.3 - 69.9

6 rows

27 3/4 - 32 1/2

70.0 - 82.6

7 rows

32 3/4 - 37 1/2

82.7 - 95.3

8 rows

37 3/4 - 42 1/2

95.4 - 108.0

9 rows

42 3/4 - 47 1/2

108.1 - 120.7

10 rows

47 3/4 - 52 1/2

120.8 - 133.4

11 rows

* 1/2 row indicates the use of Model H Nixalite®.
** 1 row or any whole numbers indicate the use of Models N, L or S Nixalite. 

How do I space it?

Now that you know how much Nixalite® will be needed, you need to know how to space the Nixalite® strips on the surface. Nixalite® Space-I-Fications provide simple rules and tolerances for positioning the Nixalite® strips on the surface. See drawings A through I for illustrations.


A

Always measure from the middle of the base strip

B

5" (12.7 cm) max. and 3 1/2" (8.9 cm) min. between models N, L and S Nixalite®. 2 1/2" (6.4 cm) max. and 2" (5.1 cm) min. between model H and  models N, L or S Nixalite®.

C

1 1/4" (3.2 cm) max. from the outside edge to the base strip of the first row for models N, L and S Nixalite®.

D

2 3/4" (7.0 cm) max. from inside wall to base strip for models N, L and S, 3/4" (1.9cm) max. from inside wall to base strip for model H Nixalite®.

E

Extend Nixalite® base strip at least 1/2" (1.3 cm) over ends of surface.

F

Nixalite® needles must extend over the outside edge at least 1/2" (1.3 cm).

G

Model W has a max. 2" (5.1cm) surface width coverage.

H

Position Model W a max. of 2 3/4" (7.0) vertical distance from installation surface.

I

Clips fastened 7/8" (2.2 cm) above the base strip fo Model W.

 

Nixalite® Bird Control

Space-I-Fication Drawings


 

 



Request for Information / Request a Catalog from Nixalite of America Inc.
 
 
 
To request more information from Nixalite of America Inc., please complete the form below.
 
*Name:    
*Email:    
Company:    
*Type:    
Phone:    
*Address:    
*Request:    
    (* = Mandatory field) 
Please add me to the mailing list for the free monthly e-Newsletter AECnews.