   Norton Door Control  Norton Series 1601/1601 BF Door Closer  

Norton Series 1601 Door Closers - Page 5

 

 

Yale Security Inc.

1601 FEATURES


FEATURES

Multi-Size Power: The closer spring assembly can be adjusted through a wide power range. An adjustment shaft accepts a 3/16" Hex wrench.

Two Power Ranges: Each series can be adjusted through a range of sizes:

Series 1601 Normal Power Range Closers, sizes 3 thru 6.

Series 1601BF Accessibility Code Closers, 1 sizes 1 thru 4.

Booster Spring - Specially designed booster spring is engineered into each unit to provide additional and necessary closing force for doors which travel beyond 110º of swing.

Tri-Style Installation: Packaged for regular arm, top jamb or parallel arm installation.

Non-Handed: Installed on either right or left hand doors for all applications.

Aluminum Alloy Shell: Norton closer shells are constructed of a special aluminum alloy which is light weight and offers proven durability.

Rack & Pinion Operation: Provides a smooth transmission of power, for control of the door through its full opening and closing cycle.

Adjustable Sweep Speed: An independent regulating valve, hex-key-operated, permits adjustment of the general closing speed.

Adjustable Latch Speed: An independent regulating valve, hex-key-operated, permits adjustment of the door's speed for approximately the last 10° of the closing cycle.

Adjustable Backcheck Cushioning: An independent regulating valve, hex-key-operated, provides an adjustable hydraulic cushion to the door opening speed toward I the end of the opening cycle.

Adjustable Delayed Action: Available in place of backcheck. Adds a third closing speed range at the beginning of the door's closing cycle.

Non-Critical Valves: All control valves for sweep speed, latch speed and backcheck cushioning or delayed action closing are non-critical and are adjusted by a standard 1/8" hex-key.

"Goof-Proof" Main-Arm Broach: The configuration and marking of the main arm broach help to assure positive alignment of lthe arm for each type of closer installation.

Corrosion Resistant Closer: The shell, pinion bushing assembly and end caps of this closer are aluminum alloy materials. All other exposed components are stainless steel, or zinc alloy materials to provide excellent resistance to corrosive environments. For standard non-hold-open applications only. Specify type of installation. Order Series 1601SS, J1601SS or P1601SS.

Narrow Profile Arm: Series 1681 (BF) closers are supplied with a narrow profile arm for non-hold-open installations. It permits regular arm installation where the minimum ceiling clearance is 1" (25 mm) and the reveal does not exceed 1 /8" (3 mm); it can be installed top jamb with a drop plate where the minimum top rail of the door is 2-3/4 (70 mm) and the frame reveal does not exceed 3" (76 mm); or it can be mounted parallel arm to raise the closer body 1" (25 mm) higher on the top rait of the door than the standard 1601 Series closer templating will permit. Order Series 1681, J1681 x (Drop Plate) or P1681.

Non-Hold-Open Arm: Standard closer will be supplied with a Non-Hold-Open Arm. This arm is non-handed.

Hold-Open Arm: Closer arm has adjustable hold-open feature (90 to 180º). This arm is non-handed. Order by suffixing "H" to the Catalog Number.

Parallel Rigid Arm: Closer supplied with a heavy-duty rigid forearm for applications where heavy traffic and heavy use are anticipated. Order by prefixing "PR" to the Catalog Number. The Non Hold-Open Parallel Rigid Arm is nonhanded. Also available in Hold-Open which is handed. Order by suffixing "H" to the Catalog Number.

CONTROL OPTIONS:

UnitroI® Door Controls UNI 1601 (BF) -- providing selectable hold-open, positive springbuffer stop. Refer to the Unitrol Door Control catalog section for details.

CloserPlus™ Door Controls CLP1601 (BF) -- providing selectable hold-open and/or a positive stop. Referto the CloserPlus catalog section for details.

Retrofit Applications --The 1601 serves to retrofit installations of sized Series 1600 door closers that do not have power adjustment capability, and which exceed A.D.A. opening force guidelines. The hole pattern of 9-1/16" (230 mm) X 3/4" (19mm) directly retrofits 1604,1605,1606 closers. Adaptor plate 1699 is available for retrofit of 1602 and 1603. These are closer installations where thru-bolts and grommet nuts (TBGN) or sex nuts (SN) have been used.


*Request for Information / Request a Catalog
 
 
 
To request more information from Norton Door Control, please complete the form below.
 
*Name:    
*Email:    
Company:    
*Company type:    
Phone:    
*Address:    
*Request:    
    (* = Mandatory field) 
Please add me to the mailing list for the free bi-monthly AECnews e-Newsletter.  
     






Printable version Bookmark this page Notify a colleague or friend about this pageHome | Terms of Use | Privacy Statement | Link to AECinfo
AECinfo is a member of Docu Group, the world's largest building products information network.



Copyright © 1996-2008 AECinfo.com