Norton Door Control
Norton Series 1601/1601 BF Door Closer
Norton Series 1601 Door Closers - Page 6
Norton Series 1601/1601 BF Door Closer
1601 REGULAR ARM
INSTALLATION Installation Drawings
Regular Arm Door Sizes And Catalog Numbers
Normal Power Range Closers 1
1 Power of closer can be adjusted to conform to the sizing requirements outlined in ANSI A156.4-1980, Standard for Door Controls-Closers. A.D.A. Accessibility Code Closers with low opening resistance. 2
2 Power of closer can be adjusted to conform to the sizing requirements outlined in A.D.A and ANSI A117.1-1980, Specifications for Making Buildings and Facilities Accessible To and Usable By Physically Handicapped People. All dimensions are for reference only. Dimensions in parentheses are millimeters unless noted otherwise. Door sizing information is based on installation on standard weight doors 7'0" (2.13 m) high 1-3/4" (44 mm) thick: hung on anti-friction hinges and operating under normal conditions. Doors in excess of 7'8" (2.34m) high or 1-3/4" (44 mm) thick: unusually heavy doors: doors templated for openings beyond 150° or doors subject to wind or draft conditions will generally require additional turns of POWER ADJUSTMENT SHAFT from that shown in the chart. |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||