1601 REGULAR ARM
INSTALLATION
Installation Drawings

Regular Arm Door Sizes And Catalog Numbers
| DIMENSIONAL INFORMATION
SHOWN IN INCHES (MILLIMETERS) |
| P MINIMUM CEILING
CLEARANCE |
U CLOSER LENGTH |
| NON-HOLD-OPEN |
HOLD OPEN |
1601 1681 |
| 1601 |
1681 |
| 1-1/2 (38) |
1 (25) |
1-5/8 (41) |
|
| 9-3/4 (248) |
Normal Power Range Closers 1
| Maximum Door Size Wood or
Metal Inches (meters) |
Power Setting* Number of
360º Turns of 3/16" Hex Drive Power Adjustment Shaft |
Norton Catalog Number for
Closing |
| Interior |
Exterior |
Non-Hold-Open |
Hold-Open |
| 34 (0.85) |
2 |
3 |
1601 1681 |
1601H |
| 36 (0.90) |
4 |
5 |
| 40 (1.00) |
6 |
7 |
| 44 (1.10) |
9 |
10 |
| 48 (1.20) |
11 |
13 |
| * 18-360º Turns Maximum
Available. Closer is set at zero turns or the lowest setting. |
1 Power of closer can be adjusted to conform
to the sizing requirements outlined in ANSI A156.4-1980, Standard for Door
Controls-Closers.
A.D.A. Accessibility Code Closers with low opening
resistance. 2
| Maximum Door Size Wood or
Metal Inches (meters) |
Power Setting* Number of
360º Turns of 3/16" Hex Drive Power Adjustment Shaft |
Norton Catalog Number for
Closing |
| Interior |
Exterior |
Non-Hold-Open |
Hold-Open |
| 34 (0.85) |
1 |
5 |
1601BF 1681BF |
1601BF-H |
| 36 (0.90) |
1 |
6 |
| 40(1.00) |
2 |
8 |
| 44 (1.10) |
3 |
Use 1601 Closer |
| 48 (1.20) |
3 |
| * 18-360º Turns Maximum
Available. Closer is set at zero turns or the lowest setting. |
2 Power of closer can be
adjusted to conform to the sizing requirements outlined in A.D.A and ANSI A117.1-1980,
Specifications for Making Buildings and Facilities Accessible To and Usable By Physically
Handicapped People.
All dimensions are for reference only. Dimensions in parentheses are
millimeters unless noted otherwise. Door sizing information is based on installation on
standard weight doors 7'0" (2.13 m) high 1-3/4" (44 mm) thick: hung on
anti-friction hinges and operating under normal conditions. Doors in excess of 7'8"
(2.34m) high or 1-3/4" (44 mm) thick: unusually heavy doors: doors templated for
openings beyond 150° or doors subject to wind or draft conditions will generally require
additional turns of POWER ADJUSTMENT SHAFT from that shown in the chart.
|