1601 PARALLEL ARM INSTALLATION


Installation Drawings

Parallel Arm+ Door Sizes And Catalog Numbers

DIMENSIONAL INFORMATION SHOWN IN INCHES (MILLIMETERS)

S

MINIMUM TOP RAIL 5/8" (16mm) FRAME STOP

T

TEMPLATE POSITION FOR 100º DOOR OPENING

WITHOUT DROP PLATE WITH DROP PLATE 1968
1601 1681 1601 1681 1601 1681
5 (127) 4 (102) 3-1/8 (79) 2-1/8 (54) 3-3/8 (86)
2-1/4 (57)

+ This door sizing information also applies to Corner Bracket mounted Closers.

Normal Power Range Closers     1

Maximum Door Size Wood or Metal Inches (meters) Power Setting* Number of 360º Turns of 3/16" Hex Drive Power Adjustment Shaft Norton Catalog Number for Closing
Interior Exterior Non-Hold Open Hold Open
34 (0.85) 3 5 (P)1601 (P)1681 (P)1601 H
36 (0.90) 5 7
40(1.00) 7 10
44(1.10) 10 14
48 (1.20) 13 16
* 18-360º Turns Maximum Available

1  Power of closer can be adjusted to conform to the sizing requirements outlined in ANSI A 156.4-1980, Standards for Door Controls-Closers.

A.D.A. Accessibility Code Closers with low opening resistance.   2

Maximum Door Size Wood or Metal Inches (meters) Power Setting* Number of 360º Turns of 3/16" Hex Drive Power Adjustment Shaft Norton Catalog Number for Closing
Interior Exterior Non-Hold-Open Hold-Open
34 (0.85) 2 8 (P)1601BF (P)1681BF (P)1601BF-H
36 (0.90) 2 9
40 (1.00) 3 12
44(1.10) 4 Use 1601 Closer
48 (1.20) 5

* 18-360º Turns Maximum Available

2   Power of closer can be adjusted to conform to the sizing requirements outlined in A.D.A and ANSI A 117.1-1980, Specifications for Making Buildings and Facilities Accessible To and Usable By Physically

*Closer is factory set at zero turns or the lowest setting.

All dimensions are for reference only. Dimensions in parentheses are millimeters unless noted otherwise. Door sizing information is based on installation on standard weight doors, 7'0" (2.13 m) high 1 -3/4" (44 mm) thick; hung on anti-friction hinges and operating under normal conditions. Doors in excess of 7'8" (2.34mm) high or 1 -3/4" (44 mm) thick; unusually heavy doors: doors templated for openings beyond 150° or doors subject to wind or draft conditions will generally require additional turns of POWER ADJUSTMENT SHAFT from that shown in the chart.




Request for Information / Request a Catalog from Norton Door Control
 
 
 
To request more information from Norton Door Control, please complete the form below.
 
*Name:    
*Email:    
Company:    
*Type:    
Phone:    
*Address:    
*Request:    
    (* = Mandatory field) 
Please add me to the mailing list for the free monthly e-Newsletter AECnews.