  Norton Door Control   Norton Powermatic® Door Controls  

Norton Powermatic® Door Controls - Page 5

   

Norton Powermatic® Door Controls

Yale Security Inc.

6600/6700 FEATURES/REQUIREMENTS


 

*See page 10 for detail


Features

  • Choice of Activation

-- Selective-6600 Series (requires switch or scanner activation).

-- Automatic/Push or Pull - 6700 Series integral switch senses door motion and activates unit. External switch or scanner may also be used to activate unit.

  • Choice of Function

-- Power Assist Function "PAS" suffix

   -- Reduced Door Opening Resistance

   -- Adjustable Motor Assist Time - (0 to 30 seconds, 5 second increments).

   --"Selector Mode Switch" - 3 Positions "OFF", "ON", "H/O" (Hold Open)

   -- Full spring power closing force.

-- Power Operator Function "POR" suffix

   -- Powered Door Opening

   -- Adjustable Door Opening Speed

   -- Adjustable "Temporary Hold Open" time (0 to 30 " seconds, 5 second increments).

   -- "Selector Mode Switch" --3 Position "OFF", "ON", "H/O" (Hold Open)

   -- Full spring power closing force.

  • Choice of Application

-- Hinge Side Application

   -- Rigid Arm and Slide Track

   -- Double Egress Arm and Slide Track

-- Stop Side Application

   -- Standard Duty Double Lever Arm (To 110° or 111° to 180°)

   -- Heavy Duty Double Lever Arm with spring buffer arm assembly [0" to 4-3/4" (0 to 121mm) or 4-13/16" to 7-3/8" (122 to 187mm)] reveal range

  • All PowerMatic® Door Controls

-- Full door closing power adjusted to a maximum of 15 lbf. measured at 1" (25mm) from the door's edge, is available in the closing cycle. Consult factory if greater door closing power is required.

-- Adjustable Sweep Closing Speed

-- Adjustable Latch Closing Speed

-- Adjustable Backcheck in Opening Cycle

-- Adjustable Backcheck Positioning in Opening Cycle

  • Choice of peripheral components:

-- Wall Switches/Frame Switch

-- Microwave/Retro-Reflective Scanners

-- Radio Frequency Transmitter- Receiver

  • Special "Vestibule Function" wiring option provided standard. May be used to synchronize the powered-up function of two consecutive doors in a pedestrian traffic path with the actuation of a single switch at either of the two doors.
  • Special warning mats or guard rails are not required.
  • "Watch Dog" Feature

If door is prevented from opening after the power cycle has been activated, the pump and motor will shut off after seven (7) seconds, preventing damage to the PowerMatic® unit. Upon closing of the door: the unit will simply reset, waiting for the next initiation.

Requirements

  • Handed

-- All closer assemblies are handed and are not field reversible. Closer assemblies for use with Rigid or Double Egress Arms are not interchangeable with closer assemblies for use with double lever arms.

  • Voltage

Input voltage 120VAC, 60 Hz. Motor and solenoid operate on 120 volts.

24VDC (Max. .500 Amps) output to operate No. 663 or No. 664 scanners, relays, etc.

  • "Blind Rivet Nuts", by others, are recommended for aluminum or under reinforced frames.