6600/6700 FEATURES/REQUIREMENTS

*See page 10 for detail
Features
-- Selective-6600 Series (requires switch
or scanner activation).
-- Automatic/Push or Pull - 6700 Series integral
switch senses door motion and activates unit. External switch or scanner may also be used
to activate unit.
-- Power Assist Function "PAS"
suffix
-- Reduced Door Opening Resistance
-- Adjustable Motor Assist Time - (0 to 30
seconds, 5 second increments).
--"Selector Mode Switch" - 3
Positions "OFF", "ON", "H/O" (Hold Open)
-- Full spring power closing force.
-- Power Operator Function "POR" suffix
-- Powered Door Opening
-- Adjustable Door Opening Speed
-- Adjustable "Temporary Hold Open"
time (0 to 30 " seconds, 5 second increments).
-- "Selector Mode Switch" --3
Position "OFF", "ON", "H/O" (Hold Open)
-- Full spring power closing force.
-- Hinge Side Application
-- Rigid Arm and Slide Track
-- Double Egress Arm and Slide Track
-- Stop Side Application
-- Standard Duty Double Lever Arm (To 110° or
111° to 180°)
-- Heavy Duty Double Lever Arm with spring
buffer arm assembly [0" to 4-3/4" (0 to 121mm) or 4-13/16" to 7-3/8"
(122 to 187mm)] reveal range
- All
PowerMatic® Door Controls
-- Full door closing power adjusted to a maximum of 15 lbf.
measured at 1" (25mm) from the door's edge, is available in the closing cycle.
Consult factory if greater door closing power is required.
-- Adjustable Sweep Closing Speed
-- Adjustable Latch Closing Speed
-- Adjustable Backcheck in Opening Cycle
-- Adjustable Backcheck Positioning in Opening Cycle
- Choice of
peripheral components:
-- Wall Switches/Frame Switch
-- Microwave/Retro-Reflective Scanners
-- Radio Frequency Transmitter- Receiver
- Special
"Vestibule Function" wiring option provided standard. May be used to synchronize
the powered-up function of two consecutive doors in a pedestrian traffic path with the
actuation of a single switch at either of the two doors.
- Special warning mats or guard rails are not
required.
- "Watch Dog" Feature
If door is prevented from opening after the power cycle has
been activated, the pump and motor will shut off after seven (7) seconds, preventing
damage to the PowerMatic® unit. Upon closing of the door: the unit will simply
reset, waiting for the next initiation.
Requirements
-- All closer assemblies are handed and are not field
reversible. Closer assemblies for use with Rigid or Double Egress Arms are not
interchangeable with closer assemblies for use with double lever arms.
Input voltage 120VAC, 60 Hz. Motor and solenoid operate on
120 volts.
24VDC (Max. .500 Amps) output to operate No. 663 or No. 664
scanners, relays, etc.
- "Blind
Rivet Nuts", by others, are recommended for aluminum or under reinforced frames.
|