 6600/6700 WIRING & TRANSMITTERS
Optional Radio Freauencv Feature "RF1 "

Chart 1 - SW2, M
DLY
| Langth of Time (Seconds) |
Sitting |
| 0.0 |
0 |
| 0.2 |
1 |
| 05 |
2 |
| 1.0 |
3 |
| 1.5 |
4 |
| 2.5 |
5 |
| 3.5 |
6 |
| 4.5 |
7 |
Chart 2 - SW3. EXSOL
DLY
| Length of Time (Seconds) |
Setting |
| 0 |
0 |
| 1 |
1 |
| 2 |
2 |
| 4 |
3 |
| 6 |
4 |
| 8 |
5 |
| 10 |
6 |
| 12 |
7 |
Chart 3 - SW4, VEST
DLY
| Length of Time (Seconds) |
Setting |
| 0 |
0 |
| 1 |
1 |
| 3 |
2 |
| 6 |
3 |
| 9 |
4 |
| 14 |
5 |
| 21 |
6 |
| 30 |
7 |
Chart 4 - SW5, CL/AS
DLY
| Length of Time (Seconds) |
Setting |
| 0 |
0 |
| 2 |
1 |
| 5 |
2 |
| 10 |
3 |
| 15 |
4 |
| 20 |
5 |
| 25 |
6 |
| 30 |
7 |
|
Switches
| Terminal |
Description |
| SW1 Dip Switches |
|
| 1 P/A |
Door Operator Function Switch OFF
position selects the Operator mode. ON position sets the Assist Mode. |
| 2 A/D |
Alarm System Delay Timer This
switch is used in conjunction with terminal J PI-1, 0/0 for optional function 2. (OFF = 30
second delay ON =60 second delay) |
| 3 RES1 |
DIAGNOSTIC USE OF FACTORY AUTHORIZED
PERSONNEL. |
| 4 RES2 |
DIAGNOSTIC USE OF FACTORY AUTHORIZED
PERSONNEL. |
| SW2 M DLY |
This rotary switch or timer pot sets the
length of delay for motor start up to allow for "unlocking" of exit devices,
electric strikes, magnetic locks, etc. See Chart 1 for delay times. |
| SW3 EXSOL DLY |
This rotary switch or timer pot sets the
length of time that a solenoid remains either energized or deenergized toallow
''unlocking." Used in conjunction with terminals JP4-3, JP4-4, JP4-5. See Chart 2 for
setting length of time. |
| SW4 VEST DLY |
This switch or timer pot sets the length of
time between receipt of the "In Vestibule" signal (terminal JP1-5) and motor
start up. See Chart 3 for delay times. |
Switches (continued)
| Terminal |
Description |
| SW1 Dip Switches |
| SW5 CL/AS DLY |
This switch or timer pot controls either one
of two function times (see chart 4 ): |
|
1. Operator Function-- Suffix
"POR" Sets length of time door holds open at the fully open position. |
|
2. Assist FunctionSuffix
"PAS" Sets length of time motor and pump will operate to reduce opening
force of door When set length of time expires the door opening force will revert to the
full opening force required for unassisted passage. |
- Radio Frequency Control Option
The radio frequency option can be ordered with the
PowerMatic unit by suffixing "RF1 " to the catalog number or it may be added to
the unit by ordering the No. 671 Radio Frequency Kit (see page 13).
Radio Frequency Function Options:
Momentary Hold-Open Function
| Wire Color |
Terminal Connection |
| Yellow |
Not used |
| Orange |
JP1-14 |
| Black |
JP4-1 |
| Brown |
JP1-13 |
| Red |
JP4-2 |
Maintained Hold-Open Function
| Wire Color |
Terminal Connection |
| Yellow |
Not used |
| Orange |
JP1-8 |
| Black |
JP4-1 |
| Brown |
JP1-7 |
| Red |
JP4-2 |
Radio frequency signal may be transmitted by either a
hand-held transmitter No. 666 (see page 13); or a wall-mounted
transmitter No. 669 (see page 13).
|