 A member of the Yale Security Group
7900 GENERAL INFORMATION
ANSI/ BHMA/ Federal Specs
For a cross reference of Norton Series 7900 Door Closers to
ANSI/BHMA/Federal FF-H-121D or FF-H-121c Specifications, see the Specification Comparison
Chart in the General Information Section of this Catalog.
U.L. Listing
Norton Series 7900 Door Closers with non hold-open feature
are listed by Underwriters' Laboratories, Inc. for use with labeled hollow-metal-doors and
frames.
WHI Listing
The Norton 790 Fire Bloc door liner is listed with Warnock
Hersey International for use in 20 minute fire doors that are listed with WHI, when used
with the Series 7900 door closer.
The combination of a Series 7900 door closer installed in a
U.L. labeled hollow metal-door frame and a Norton Number 790 Fire Bloc installed in a WHI
labeled 20 minute fire door, which has the tested preparation, may qualify as a 20 minute
fire door assembly. Always consult local authorities to determine the acceptance and
proper application of fire door and hardware applications.
Available Finishes
Sprayed Finishes - All Norton Series 7900
Closers are available in the following sprayed finishes. Order sprayed finishes by the
Norton Symbol.
| Finish Description |
Norton Symbol |
BHMA Symbol |
| Aluminum |
AL |
689 |
| Dull Bronze |
DB |
691 |
| Dark Statuary Bronze |
STAT |
690 |
| Black |
315 |
693 |
| Gold |
GB |
N/A |
| To Compliment
Duranodic |
| Medium Amber |
312 |
694 |
| Dark Amber |
313 |
695 |
| Black |
315 |
693 |
| Corrosion Inhibitor |
| Prime Coat (Beige)* |
SRI |
600 |
*Available at extra cost. Closers can be ordered prime
coated only. i.e. (SRI), or prime coated with finish coat. i.e. (SRI) x (DB).
Suggested Specification
Closers for __________________ exterior (and) interior
doors shall be full rack-and-pinion type with cast aluminum alloy shell. Closers shall be
concealed in a 4" (102 mm) high frame header. The slide track shall be concealed in
the top rail of the door. (Closer shall be provided with a fire-blocking door liner to
permit installation in 20 minute fire door assemblies.) Closer, arm and slide track shall
be completely concealed when the door is closed. Hydraulic fluid shall be non-gumming and
non-freezing. Closer shall have (four) (five) noncritical valves, hex-key-operated, to
independently regulate sweep speed, latch speed (backcheck position and backcheck
cushioning)(and delayed action closing). (Closer shall have power adjustment to permit a
50% increase in power over the minimum closing force for any size.) (Closer shall conform
with Accessibility Code specifications.) Degree of stop is adjustable in field by slider.
Hold-Open mechanism shall be capable of disengagement when
holding function is not required. Hold-Open mechanism shall be fully adjustable by slide
mechanism. Point of hold open is set in field. Hold open shall release with a manual
pressure on the edge of the door in the direction of close. Slide track shall have
built-in cushioning shock-absorber mechanism. (Closer to be Norton Series 7900) (with
Norton #790 Fire Bloc.) (Closer to be Norton Series 7900BF.) |