 INSTALLATION
Regular Arm Installation

| P Minimum Ceiling Clearance |
| Non-Hold Open |
Hold Open |
| 1-1/2 (38) |
1-5/8 (41) |
Top Jamb Installation

| P Minimum
Ceiling Clearance |
S Minimum
Top Rail 5/8 (16) Frame Stop |
| Without Drop Plate |
With 9388 Drop Plate |
Without Drop Plate |
With 9388 Drop Plate |
| 2-5/8 (67) |
1-3/4 (44) |
1-7/8 (48) |
3-3/8 (86) |
Parallel Arm Installation

| R* Minimum
Top Rail 5/8 (16) Frame Stop |
| Without Drop Plate |
With 9388 Drop Plate |
| 5 (127) |
2-5/8 (67) |
All Dimensions are for reference only and are in inches
(mm) unless otherwise noted. Door sizing information is based on
installa-tiononstandardweightdoors,7'0" (2.13m) high x 1-3/4" (44mm) thick: hung
on antifriction hinges and operating under normal conditions. Doors in excess of 7'8"
(2.34m) high or 1-3/4" (44mm) thick, templated openings beyond 150° or doors subject
to wind or draft conditions will generally require the next larger size closer.
Note: Door closing force is not
adjustable. Correct size door closer must be selected .
Interior Doors
| Door Closer Size |
Recommended Max. Door
Width Inches (mm) |
| Reg. Arm |
Top Jamb |
Para. Arm |
| 2 |
34 (864) |
34 (864) |
32 (813) |
| 3 |
40 (1016) |
40 (1016) |
38 (965) |
| 4 |
48 (1219) |
48 (1219) |
46 (1168) |
| 5 |
---- |
--- |
52 (1321) |
Exterior Doors
| Door Closer Size |
Recommended Max. Door
Width Inches (mm) |
| Reg. Arm |
Top Jamb |
Para. Arm |
| 2 |
30 (782) |
30 (782) |
28 (711) |
| 3 |
34 (864) |
34(864) |
32 (813) |
| 4 |
40 (1016) |
40(101) |
36 (914) |
| 5 |
48 (1219) |
48 (1219) |
42 (1067) |
|