CLOSERPLUS SERIES CLP-8301 Catalog Numbers and Dimensional Data
All dimensions are for reference only. Closer Power Adjustment The following charts are a guide to set the CloserPlus door closer power. Installer must further adjust the closer to accommodate door, frame, degree( of opening, environment or "Code" requirements. Closer factory set at minimum power (zero turns). Series CLP-8301 BFAccessibility Code Power Range
Power of control can be adjusted to conform to sizing requirements outlined in A.D.A. and ANSI A117.1-1986, Specifications for Making Buildings and Facilities Accessible To and Usable By Physically Handi-capped People. Series CLP-8301Normal Power Range
Power of control can be adjusted to conform to conventional sizing requirements outlined in A.D.A. and ANSI A156.4-1986, Standards for Door Controls - Closers. Accessories For Arm Mounting accessories, see page CLOSERPLUS-20.
Narrow Top Rail #8148 Drop Plate; Universal: For use where a narrow top rail prevents the closer from being mounted directly to the door surface. This Drop Plate can be used to mount a closer on a top rail as narrow as 2-3/8" (60mm)hn height.