 A member of the Yale Security Group
SERIES 7970DPS INSTALLATION
Installation Dimension:

All dimensions are for reference only. Dimensions in parentheses are
millimeter unless noted otherwise. Door sizing information is based on installation on
standard weight doors 7'0" (2.13m) high, 1-3/4" (44mm) thick, hung and operating
under normal conditions.
All Series 7970 closers are shipped with a slide track 25"
(635mm) long.
For narrower doors a shorter length slide track is required. The
track may be cut to desired length at the time of installation. This provides versatility
and assures proper length track. The template position for the slide track must always be
measured form the centerline of the door's pivot point.
Butt Hinge Installation
Non-Hold Open
Minimum door width 27". Track 25" long. Use of stop and
cushion block up to 110°. Use of auxiliary door stop is required for openings greater
than 110°, up to 180° conditions permitting.
3/4" Offset Pivot Installation
Non Hold-Open
Openings to 95° when separate door stop (not supplied) is used. For
doors less than 29" wide, contact Factory.
Wiring: Switch rating 5 amps @ 30 VDC/250 VAC. Switch is
momentary contact single pole double throw.
a. Red lead from switch is open contact. Power is OFF when
door is in fully closed position but is ON when door is opened more than 1/4". Used
to communicate "open door" situation.
b. Black lead from switch is closed contact. Power is ON when
door is in fully closed position but power is OFF when door is opened more than 1/4".
Used to communicate "closed door" situation.
c. White lead from switch connects to power input.

Wiring of switch must be in compliance with N.E.C. Class 2
wiring specifications.
Series 7970 Door Sizing |
Maximum Door Width |
Closer Size |
Interior |
Exterior |
|
32 (0.81) |
--- |
4 |
38 (0.97) |
32 (0.81) |
5 |
48 (1.22) |
38 (0.97) |
6 |
Door sizing information is based on installation on standard weight
doors hung on antifriction hinges or pivots and operating under normal conditions. Use
next larger size closer where draft conditions exist oar where door swings beyond 150°.
Accessibility
Code Compliance
Maximum Door Width Wood or Metal |
Closer Size |
Interior |
Exterior |
48 (1.22) |
---- |
OBFI |
---- |
36 (0.91) |
OBFE |
|