   Norton Door Control  Norton Unitrol® Door Controls  

Norton Unitrol® Door Controls - Page 27

 

 

Norton Series UNI-J8301

Unitrol Door Controls
Top Jamb Installation

Catalog Numbers

UNITROL CATALOG NUMBERS

NORMAL POWER RANGE

ACCESSIBILITY CODE POWER RANGE

x SPECIFY FRAME REVEAL

STOP ONLY ARM

HOLD-OPEN ARM

STOP ONLY ARM

HOLD-OPEN ARM

UNI-J8301

UNI-J8301H

UNI-J8301 BF

UNI-J8301BF-H

Dimensional Data

DIMENSIONAL INFORMATION SHOWN IN INCHES (MILLIMETERS)

M

MINIMUM FRAME FACE

P

MINIMUM CEILING CLEARANCE

S*

MINIMUM TOP RAIL CLEARANCE

T

TEMPLATE POSITION FOR HOLD-OPEN AT LISTED ANGLE OR DEAD STOP AT LISTED ANGLE PLUS 5°

WITHOUT DROP PLATE

WITH DROP PLATE

WITHOUT DROP PLATE

WITH DROP PLATE

WITHOUT DROP PLATE

WITH DROP PLATE

85°

90°

95°

100°

105°

110°

1-3/4 (44)

8148 1-1/2 (38)

2-3/4 (70)

8148 1-1/2 (38)

1-7/8 (48)

8148 3-3/4 (95)

9-1/2 (241)

8-7/8 (225)

8-1/4 (210)

7-3/4 (197)

7-3/8 (187)

7 (178)

*Minimum top rail dimensions shown are with Arm Shoe Shock Absorber mounted above secondary arm. All dimensions are for reference only.

Closer Power Adjustment

The following charts are a guide to set the Unitrol door closer power. Installer must further adjust the closer to accommodate door, frame, degree of opening, environment or "Code" requirements. Closer factory set at minimum power (zero turns).

Series UNI-J8301 Normal Power Range Controls

DOOR SIZE WOOD OR METAL INCHES (METERS)

POWER ADJUSTMENT FULL 360° CLOCK WISE TURNS OF ADJUSTMENT NUT

UNITROL CATALOG NUMBER

INTERIOR

EXTERIOR

STOP ONLY ARM

HOLD-OPEN ARM

28-36 (0.70-0.90)

3

6

UNI-J8301

UNI-J8301BF

37-42 (0.95-1.05)

6

7

43-48 (1.10-1.20)

8

11

MAXIMUM TURNS AVAILABLE 15

Closer power can be adjusted to conform to conventional sizing requirements outlined in ANSI A156.4-1986, Standards for Door Controls - Closers.

Series UNI-J8301BF Accessibility Code Power Range

DOOR SIZE WOOD OR METAL INCHES (METERS)

POWER ADJUSTMENT FULL 360° CLOCKWISE TURNS OF ADJUSTMENT NUT

UNITROL CATALOG NUMBER

INTERIOR

EXTERIOR

STOP ONLY ARM

HOLD-OPEN ARM

28-36 (0.70-0.90)

2

4

UNI-J8301BF

UNI-J8301BF-H

37-42 (0.95-1.05)

5

7

43-48 (1.10-1.20)

7

10

MAXIMUM TURNS AVAILABLE 15

Closer power can be adjusted to conform to the requirements outlined in ANSI A 117.1-1980, Specifications for Making Buildings and Facilities Accessible To and Usable By Physically Handicapped People.


Accessories

Low Ceiling Clearance -- #8148 Drop Plate: For use where low ceiling clearance prevents normal top jamb mounting. This plate is used when the clearance is from 1-1/2" to 2-3/4" (38mm to 70mm).

1-3/4" high x 2-1/8" deep x 13" long (44mm x 54mm x 330mm)

Molded Slim Style Cover -- #8200P: Standard. Available in any of the "Sprayed Finishes" listed on page UNITROL-3. Cover fastens to closer with two attaching screws, included.

*Request for Information / Request a Catalog
 
 
 
To request more information from Norton Door Control, please complete the form below.
 
*Name:    
*Email:    
Company:    
*Company type:    
Phone:    
*Address:    
*Request:    
    (* = Mandatory field) 
Please add me to the mailing list for the free bi-monthly AECnews e-Newsletter.  
     






Printable version Bookmark this page Notify a colleague or friend about this pageHome | Terms of Use | Privacy Statement | Link to AECinfo
AECinfo is a member of Docu Group, the world's largest building products information network.



Copyright © 1996-2008 AECinfo.com