Dimensional Data
*Minimum top rail dimensions shown are with Arm Shoe Shock Absorber mounted above secondary arm. All dimensions are for reference only. Closer Power Adjustment The following charts are a guide to set the Unitrol door closer power. Installer must further adjust the closer to accommodate door, frame, degree of opening, environment or "Code" requirements. Closer factory set at minimum power (zero turns). Series UNI-J8301 Normal Power Range Controls
Closer power can be adjusted to conform to conventional sizing requirements outlined in ANSI A156.4-1986, Standards for Door Controls - Closers. Series UNI-J8301BF Accessibility Code Power Range
Closer power can be adjusted to conform to the requirements outlined in ANSI A 117.1-1980, Specifications for Making Buildings and Facilities Accessible To and Usable By Physically Handicapped People. Accessories
Low Ceiling Clearance -- #8148 Drop Plate: For use where low ceiling clearance prevents normal top jamb mounting. This plate is used when the clearance is from 1-1/2" to 2-3/4" (38mm to 70mm).
1-3/4" high x 2-1/8" deep x 13" long (44mm x 54mm x 330mm) Molded Slim Style Cover -- #8200P: Standard. Available in any of the "Sprayed Finishes" listed on page UNITROL-3. Cover fastens to closer with two attaching screws, included. |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||