Pflow Industries, Inc.
Pflow Vertical Lifts
Series DB and FM Specifications
Pflow Vertical Lifts
Series DB Specifications GENERAL Standard power requirements are 208V/
230V/460V, 3-phase. Control voltage is 110V. Control panel is designed to be mounted to
the back of the frame. Push buttons are mounted in the panel door to allow manual control
only. Series FM Specifications GENERAL Pflow Series FM Vertical Lifts move materials between two levels. Principal components are guide columns, carriage and hydraulic actuating mechanism. APPLICATION DATA Please specify your application requirements: Lifting Capacity:_____lbs. NOTE: Series FM Vertical Lifts are available with: Lifting capacities to 6,000 Ibs; Carriage sizes to 8' x 8'; Vertical rise to 20'. Standard travel speed is 18 fpm. Travel speeds up to 25 fpm are available on special order. STRUCTURE Guide columns are 6" roll-formed sections. Carriage is fabricated of 4" or 6" structural members with steel deck plate. Other deck surfaces can be supplied. Carriage is available in straddle or cantilever styles (see back page for more information on carriage styles). OPERATION Carriage is lifted and lowered 6y
direct-acting hydraulic cylinders operating in a pull mode. Cylinders are actuated by o
remote mounted hydraulic pump. Transmission of the lifting force is direct from the top of
the columns to the carriage using a TruPull cylinder. FM Lift has no cables, chains or
other flexible lifting means that require safety cams to prevent ELECTRICAL Standard power requirements are 208V/ 230V/460V, 3-phase. Control voltage is 24V. Control stations and remote mounted control panel are NEMA 12. Control stations, provided for each level, include self-maintaining, push buttons with mushroom-head E-Stop button. SAFETY FEATURES Upward travel of the carriage is limited by positive mechanical stops that assure positive leveling with the upper deck. Redundant overload protection is provided to positively prevent raising of the carriage if loaded to more than 110% of rated capacity. Velocity fuses prevent uncontrolled descent in case of hydraulic hose rupture. NO RIDER signs are posted at each point of operation. Optional DeckLocks available. CARRIAGE & SAFETY ENCLOSURES Carriage is equipped with safety rails on non operating ends and safety chains or diagonal drop bars on operating ends. Optional expanded metal or sheet metal carriage enclosures are available. Mandatory safety enclosures provide guarding on all sides of the lift. Enclosures are a minimum of 8' high consisting of material which will reject a ball 3/4" in diameter. Gates are provided for access during loading and unloading. Gates are electrically and mechanically interlocked with carriage movement. Interlock prevents a gate from being opened unless the carriage is at the designated level. Interlock also prevents carriage movement if any gate is not fully closed and locked.
|