PRU - 1
| Catalog No.: |
PRU-1-A-04-2T8-SC-YMW-S-120 |
| Lamp Type: |
(2) F32T8 |
| Test report No.: |
LSI 13481 |
Body Styles A & B |
| Ballast positions and reflector
variations |
 |
Body style C |
| Body style D |

Coefficients of Utilization
| Floor |
effective
floor cavity reflectance = .20 |
| Ceiling |
80 |
70 |
50 |
| Wall |
70 |
50 |
30 |
10 |
70 |
50 |
30 |
10 |
50 |
30 |
10 |
| RCR |
0 |
.72 |
.72 |
.72 |
.72 |
.62 |
.62 |
.62 |
.62 |
.43 |
.43 |
.43 |
|
1 |
.65 |
.62 |
.60 |
.57 |
.56 |
.54 |
.51 |
.49 |
.37 |
.36 |
.35 |
|
2 |
.59 |
.54 |
.50 |
.46 |
.51 |
.47 |
.43 |
.40 |
.33 |
.30 |
.29 |
|
3 |
.54 |
.48 |
.43 |
.39 |
.46 |
.41 |
.37 |
.34 |
.29 |
.26 |
.24 |
| |
4 |
.49 |
.42 |
.37 |
.33 |
.42 |
.36 |
.32 |
.28 |
.25 |
.23 |
.20 |
|
5 |
.45 |
.37 |
.32 |
.28 |
.39 |
.32 |
.28 |
.24 |
.23 |
.20 |
.17 |
|
6 |
.41 |
.33 |
.28 |
.24 |
.35 |
.29 |
.24 |
.21 |
.20 |
.17 |
.15 |
|
7 |
.38 |
.30 |
.24 |
.20 |
.33 |
.26 |
.21 |
.18 |
.18 |
.15 |
.13 |
|
8 |
.35 |
.27 |
.21 |
.18 |
.30 |
.23 |
.19 |
.15 |
.16 |
.13 |
.11 |
|
9 |
.32 |
.24 |
.19 |
.15 |
.28 |
.21 |
.17 |
.13 |
.15 |
.12 |
.10 |
|
10 |
.30 |
.22 |
.17 |
.14 |
.26 |
.19 |
.15 |
.12 |
.13 |
.11 |
.09 |
Zonal Lumen Summary
| Zone |
Lumens |
% Lamp |
% Luminaire |
| 0-30º |
45 |
.75 |
1.00 |
| 0-40º |
74 |
1.18 |
1.58 |
| 0-60º |
114 |
1.88 |
2.51 |
| 0-90º |
138 |
2.28 |
3.04 |
| 40-90º |
66 |
1.10 |
1.46 |
| 60-90º |
23 |
.39 |
.53 |
| 90-180º |
4428 |
72.59 |
96.96 |
| 0-180º |
4566 |
74.87 |
100.00 |
efficiency = 74.9%
PRU-3
| Catalog No.: |
PRU-3-A-04-2T8-SC-YMW-S-120 |
| Lamp Type: |
(2) F32T8 |
| Test report No.: |
LSI 13483 |
 |

Coefficients of Utilization
Floor |
effective floor cavity
reflectance = .20 |
| Ceiling |
80 |
70 |
50 |
| Wall |
70 |
50 |
30 |
10 |
70 |
50 |
30 |
10 |
50 |
30 |
10 |
| RCR |
0 |
.80 |
.80 |
.80 |
.80 |
.69 |
.69 |
.69 |
.69 |
.47 |
.47 |
.47 |
|
1 |
.73 |
.69 |
.66 |
.64 |
.62 |
.59 |
.57 |
.54 |
.41 |
.39 |
38 |
|
2 |
.66 |
.60 |
.55 |
.51 |
.56 |
.52 |
.48 |
.44 |
.36 |
.33 |
.31 |
|
3 |
.60 |
.53 |
.47 |
.43 |
.51 |
.45 |
.41 |
.37 |
.28 |
.25 |
.22 |
| |
4 |
.55 |
.47 |
.41 |
.36 |
.47 |
.40 |
.35 |
.31 |
.28 |
.25 |
.22 |
|
5 |
.50 |
.40 |
.35 |
.30 |
.43 |
.35 |
.30 |
.26 |
.25 |
.21 |
.19 |
|
6 |
.46 |
.37 |
.30 |
.26 |
.39 |
.32 |
.26 |
.23 |
.22 |
.19 |
.16 |
|
7 |
.42 |
.33 |
.27 |
.22 |
.36 |
.28 |
.23 |
.19 |
.20 |
.16 |
.14 |
|
8 |
.39 |
.29 |
.23 |
.19 |
.33 |
.25 |
.20 |
.17 |
.18 |
.14 |
.12 |
|
9 |
.36 |
.27 |
.21 |
.17 |
.31 |
.23 |
.18 |
.15 |
.16 |
.13 |
.10 |
|
10 |
.33 |
.24 |
.19 |
.15 |
.29 |
.21 |
.16 |
.13 |
.15 |
.11 |
.09 |
Zonal Lumen Summary
| Zone |
Lumens |
% Lamp |
% Luminaire |
| 0-30º |
7 |
.13 |
.16 |
| 0-40º |
13 |
.23 |
.27 |
| 0-60º |
30 |
.49 |
.59 |
| 0-90º |
61 |
1.01 |
1.20 |
| 40-90º |
47 |
.78 |
.93 |
| 60-90º |
31 |
.52 |
.62 |
| 90-180º |
5047 |
82.74 |
98.80 |
| 0-180º |
5108 |
83.75 |
100.0 |
efficiency = 83.8%
PRU - 5
| Catalog No.: |
PRU-5-04-2T8-SC-YMW-W-120 |
| Lamp Type: |
(2) F32T8 |
| Test report No.: |
LSI 10665 |
 |

Coefficients of Utilization
Floor |
effective floor cavity
reflectance = .20 |
| Ceiling |
80 |
70 |
50 |
| Wall |
70 |
50 |
30 |
10 |
70 |
50 |
30 |
10 |
50 |
30 |
10 |
| RCR |
0 |
.90 |
.90 |
.90 |
.90 |
.82 |
.82 |
.82 |
.82 |
.67 |
.67 |
.67 |
|
1 |
.83 |
.80 |
.77 |
.74 |
.75 |
.73 |
.70 |
.67 |
.60 |
.58 |
.56 |
|
2 |
.76 |
.70 |
.66 |
.61 |
.69 |
.64 |
.60 |
.57 |
.53 |
.50 |
.48 |
|
3 |
.70 |
.62 |
.57 |
.52 |
.64 |
.57 |
.52 |
.48 |
.47 |
.44 |
41 |
| |
4 |
.64 |
.56 |
.49 |
.44 |
.58 |
.51 |
.46 |
.41 |
.42 |
.38 |
.35 |
|
5 |
.59 |
.49 |
.43 |
.38 |
.53 |
.45 |
.40 |
.35 |
.38 |
.34 |
.30 |
|
6 |
.54 |
.44 |
.38 |
.33 |
.49 |
.41 |
.35 |
.31 |
.34 |
.30 |
.26 |
|
7 |
.50 |
.40 |
.33 |
.28 |
.45 |
.36 |
.31 |
.27 |
.30 |
.26 |
.23 |
|
8 |
.46 |
.35 |
.29 |
.25 |
.43 |
.33 |
.27 |
.23 |
.27 |
.23 |
.20 |
|
9 |
.42 |
.32 |
.26 |
.21 |
.38 |
.29 |
.24 |
.20 |
.25 |
.20 |
.17 |
|
10 |
.39 |
.29 |
.23 |
.19 |
.36 |
.27 |
.21 |
.18 |
.22 |
.18 |
.15 |
Zonal Lumen Summary
| Zone |
Lumens |
% Lamp |
% Luminaire |
| 0-30º |
617 |
10.65 |
12.35 |
| 0-40º |
1041 |
17.96 |
20.83 |
| 0-60º |
1780 |
30.69 |
35.61 |
| 0-90º |
1956 |
33.73 |
39.14 |
| 40-90º |
915 |
15.78 |
18.31 |
| 60-90º |
176 |
3.04 |
3.53 |
| 90-180º |
3042 |
52.45 |
60.86 |
| 0-180º |
4998 |
86.19 |
100.00 |
efficiency = 86.2%
PRU - 7
| Catalog No.: |
PRU-7-04-2T8-SC-YMW-OW-120 |
| Lamp Type: |
(2) F32T8 |
| Test report No.: |
LSI 13486 |
 |

Coefficients of Utilization
Floor |
effective floor cavity
reflectance = .20 |
| Ceiling |
80 |
70 |
50 |
| Wall |
70 |
50 |
30 |
10 |
70 |
50 |
30 |
10 |
50 |
30 |
10 |
| RCR |
0 |
.86 |
.86 |
.86 |
.86 |
.81 |
.81 |
.81 |
.81 |
.74 |
.74 |
.74 |
|
1 |
.77 |
.73 |
.70 |
.67 |
.73 |
.70 |
.67 |
.64 |
.63 |
.61 |
.59 |
|
2 |
.70 |
.64 |
.58 |
.54 |
.66 |
.61 |
.56 |
.52 |
.55 |
.51 |
.48 |
|
3 |
.64 |
.56 |
.50 |
.45 |
.60 |
.53 |
.48 |
.43 |
.48 |
.44 |
.40 |
| |
4 |
.58 |
.49 |
.43 |
.38 |
.55 |
.47 |
.41 |
.36 |
.43 |
.38 |
.34 |
|
5 |
.53 |
.44 |
.37 |
.32 |
.51 |
.42 |
.36 |
.31 |
.38 |
.33 |
.29 |
|
6 |
.49 |
.39 |
.33 |
.28 |
.47 |
.38 |
.32 |
.27 |
.34 |
.29 |
.25 |
|
7 |
.46 |
.36 |
.29 |
.24 |
.43 |
.34 |
.28 |
.24 |
.31 |
.26 |
.22 |
|
8 |
.42 |
.32 |
.26 |
.22 |
.40 |
.31 |
.25 |
.24 |
.28 |
.23 |
.20 |
|
9 |
.39 |
.30 |
.23 |
.19 |
.37 |
.28 |
.23 |
.19 |
.26 |
.21 |
.18 |
|
10 |
.37 |
.27 |
.21 |
.17 |
.35 |
.26 |
.21 |
.17 |
.24 |
.19 |
.16 |
Zonal Lumen Summary
| Zone |
Lumens |
% Lamp |
% Luminaire |
| 0-30º |
835 |
14.4 |
19.00 |
| 0-40º |
1376 |
23.7 |
31.40 |
| 0-60º |
2465 |
42.5 |
56.20 |
| 0-90º |
3306 |
57.0 |
75.40 |
| 90-120º |
535 |
9.20 |
12.20 |
| 90-130º |
724 |
12.50 |
16.50 |
| 90-150º |
1003 |
17.30 |
22.90 |
| 90-180º |
1081 |
18.60 |
24.60 |
| 0-180º |
4387 |
75.60 |
100.00 |
efficiency = 75.6%

PRUDENTIAL LIGHTING
1774 East 21st Street
P.O. Box 58736
Los Angeles, CA 90058-0736
213 746-0360 fax: 213 746-8838
www.prulite.com |