| PHOTOMETRIC DATA 
PV-50-2-04-RS-M2 (2-Lamp, Cable or Stem Mount)
| COEFFICIENTS
OF UTILIZATION |
| % CEILING
REFLECTANCE |
80 |
70 |
50 |
| % WALL
REFLECTANCE |
70 |
50 |
30 |
70 |
50 |
30 |
50 |
30 |
10 |
| ROOM CAVITY
RATIO |
FLOOR
CAVITY REFLECTANCE, 20% |
| 0 |
.80 |
.80 |
.80 |
.68 |
.68 |
.68 |
.46 |
.46 |
.46 |
| 1 |
.72 |
.69 |
.66 |
.62 |
.59 |
.57 |
.40 |
.39 |
.38 |
| 2 |
.66 |
.60 |
.55 |
.56 |
.51 |
.47 |
.35 |
.33 |
.31 |
| 3 |
.60 |
.53 |
.47 |
.51 |
.45 |
.41 |
.31 |
.28 |
.26 |
| 4 |
.55 |
.46 |
.40 |
.46 |
.40 |
.35 |
.27 |
.24 |
.22 |
| 5 |
.50 |
.40 |
.35 |
.42 |
.35 |
.30 |
.24 |
.21 |
.19 |
| 6 |
.46 |
.37 |
.30 |
.39 |
.31 |
.26 |
.22 |
.18 |
.16 |
| 7 |
.42 |
.33 |
.27 |
.36 |
.26 |
.23 |
.19 |
.16 |
.14 |
| 8 |
.39 |
.29 |
.23 |
.33 |
.25 |
.20 |
.17 |
.14 |
.12 |
| 9 |
.36 |
.26 |
.21 |
.30 |
.23 |
.18 |
.16 |
.13 |
.10 |
| 10 |
.33 |
.24 |
.19 |
.28 |
.21 |
.16 |
.14 |
.11 |
.09 |

PV-50-2-04-RS-M4 (2-Lamp, Wall Mount)
| COEFFICIENTS
OF UTILIZATION |
| % CEILING
REFLECTANCE |
80 |
70 |
50 |
| % WALL
REFLECTANCE |
70 |
50 |
30 |
70 |
50 |
30 |
50 |
30 |
10 |
| ROOM CAVITY
RATIO |
FLOOR
CAVITY REFLECTANCE, 20% |
| 0 |
.80 |
.80 |
.80 |
.69 |
.69 |
.69 |
.47 |
.47 |
.47 |
| 1 |
.73 |
.70 |
.67 |
.62 |
.60 |
.57 |
.41 |
.39 |
.38 |
| 2 |
.66 |
.61 |
.56 |
.57 |
.52 |
.48 |
.36 |
.33 |
.31 |
| 3 |
.61 |
.53 |
.48 |
.52 |
.46 |
.41 |
.31 |
.29 |
.26 |
| 4 |
.55 |
.47 |
.41 |
.47 |
.40 |
.35 |
.28 |
.25 |
.22 |
| 5 |
.50 |
.41 |
.35 |
.43 |
.36 |
.31 |
.25 |
.21 |
.19 |
| 6 |
.46 |
.37 |
.31 |
.39 |
.32 |
.27 |
.22 |
.19 |
.16 |
| 7 |
.43 |
.33 |
.27 |
.36 |
.28 |
.23 |
.20 |
.16 |
.14 |
| 8 |
.39 |
.30 |
.24 |
.33 |
.26 |
.21 |
.18 |
.14 |
.12 |
| 9 |
.36 |
.27 |
.21 |
.31 |
.23 |
.18 |
.16 |
.13 |
.11 |
| 10 |
.34 |
.24 |
.19 |
.29 |
.21 |
.16 |
.15 |
.11 |
.09 |

| FIXTURE SERIES |
LAMP ROWS |
NOMINAL LENGTH
(FEET) |
RAPID START (430
MA) ADD |
OCTIC T-8 (265
MA) ADD |
MOUNTING |
| PV-50 |
-1 -2 |
-03 -04
-05*
-06
-08
-10* |
RS RSE
RSTW
RSETW
XRSE
XRSETW |
CT CTE
CTTW
CTETW
XCTE
XCTETW |
-M2 (STEM) -M3 (CABLE)
-M4 (WALL BRACKET) |
*CT only
EMERGENCY APPLICATIONS : All fixtures are
available with Emergency Components. Specify prefix "PEL" (600
lumen output) or "PEH" (1200 lumen output).
SPECIFICATIONS
TYPE :
CONSTRUCTION: Die - formed, prime quality
steel
REFLECTOR: Die -formed, high reflectance
Baked White Enamel.
FINISH: Matte White Enamel (standard).
Other finishes available.
LABELS: UL, IBEW.
For Aluminum Body add suffix "-AL".
NOTE: Row information required.
For Electronic Ballast add "E" to
RS or CT.
Ex: RSE or CTE.
For a 3- or 4- lamp Electronic Ballast add "X"
to RSE or CTE.
Ex: XRSE or XCTE.
For complete listing, see Fixture Nomenclature in Technical
Data section.
 |
PRUDENTIAL LIGHTING 1774 East 21st