architecture - engineering - construction
Prudential Lighting
Special Applications
Special Applications - Page 8
Special Applications
PHOTOMETRIC DATA
P-5362-04RS-WA (2-Lamp)

| COEFFICIENTS OF UTILIZATION |
| % CEILING REFLECTANCE |
80 |
50 |
30 |
| % WALL REFLECTANCE |
50 |
30 |
10 |
50 |
30 |
10 |
50 |
30 |
10 |
| ROOM CAVITY RATIO |
FLOOR CAVITY REFLECTANCE, 20% |
| 1 |
.65 |
.61 |
.58 |
.61 |
.58 |
.55 |
.56 |
.54 |
.52 |
| 2 |
.57 |
.52 |
.49 |
.54 |
.50 |
.47 |
.50 |
.47 |
.44 |
| 3 |
.51 |
.45 |
.41 |
.48 |
.44 |
.40 |
.45 |
.41 |
.38 |
| 4 |
.45 |
.39 |
.35 |
.43 |
.38 |
.34 |
.40 |
.36 |
.33 |
| 5 |
.41 |
.35 |
.31 |
.39 |
.34 |
.30 |
.36 |
.32 |
.29 |
| 6 |
.37 |
.31 |
.27 |
.35 |
.30 |
.26 |
.33 |
.29 |
.26 |
| 7 |
.34 |
.28 |
.24 |
.32 |
.27 |
.23 |
.30 |
.26 |
.23 |
| 8 |
.31 |
.25 |
.21 |
.29 |
.25 |
.21 |
.28 |
.24 |
.21 |
| 9 |
.28 |
.23 |
.19 |
.27 |
.23 |
.19 |
.26 |
.22 |
.19 |
| 10 |
.26 |
.21 |
.17 |
.25 |
.21 |
.17 |
.24 |
.20 |
.17 |
SERVICING

| INSTALLATION 
We reserve the right to change details of design, material
or finish in any way that will not alter appearance, reduce function or performance.
 |
1774 E. 21st ST. LOS ANGELES, CA 90058
213.746.0360 Fax: 213.746.8838 |
|
|
|