Sanyo Air Conditioning Prod.
Ductless Air Conditioning and Heat Pump Products
Wall-Mounted Heat Pumps-page 3
Ductless Air Conditioning and Heat Pump Products
![]()
![]() |
F E A T U R E S
- 24-Hour ON/OFF Program Timer
- Electric-Resistant Back-up Heater (Except 09KHS21/36KHS32)
- Automatic Defrost Cycle
- Heating/Cooling Automatic Changeover
- Hot Start System
- Self Diagnostic Feature
- Non-Polar Wiring
- Night Set Back
- Auto Louver (Except 09KHS21 & 09KHS22)
| Wall Mounted Heat Pumps | |||||||
| Model No. | 09KHS21 |
09KHS22 |
12KHS32 |
||||
| Unit Model No. | Indoor Unit |
Outdoor Unit |
Indoor Unit |
Outdoor Unit |
Indoor Unit |
Outdoor Unit |
|
KHS0921 |
CH0921 |
KHS0922 |
CH0922 |
KHS1232 |
CH1232 |
||
| Performance & Electrical Ratings |
|
|
|
||||
| Capacity BTU/H | Cooling | 9,000 |
9,000/8,800 |
11,700/11,500 |
|||
| Heating | 10,800 |
10,900/10,700 |
13,000/12,700 |
||||
| Moisture Removal (High) Pints/H | 2.2 |
2.2/2.1 |
3.3/3.2 |
||||
| Dry Air Flow (Hi/Med/Low) | 220/190/160 |
220/190/160 |
360/310/260 |
||||
| SEER | 10.0 |
10.0/10.0 |
10.0/10.0 |
||||
| HSPF | 6.8 |
6.8/6.8 |
6.8/6.8 |
||||
| Voltage Rating | 115 |
230/208 |
230/208 |
||||
| Running Amps | Cooling | 8.2 |
4.5/4.6 |
5.6/5.9 |
|||
| Heating | 8.8 |
4.7/4.8 |
5.2/5.5 |
||||
| Power Input | Cooling | 930 |
950/930 |
1,210/1,180 |
|||
| Heating | 1,010 |
1,030/980 |
1,170/1,120 |
||||
| Back-up Heater KW |
|
1.0/0.82 |
1.5/1.23 |
||||
| Maximum Fuse Size Amps | 15 |
15 |
20 |
||||
| Features |
|
|
|
||||
| Controls | Microcomputer |
Microcomputer |
Microcomputer |
||||
| Low Ambient Control | * Optional |
* Optional |
* Optional |
||||
| Fan Speeds | 3+ Automatic |
3+ Automatic |
3+ Automatic |
||||
| Timer | On/Off/24-Hour |
On/Off/24-Hour |
On/Off/24-Hour |
||||
| Air Deflection | (Horizontal) | Manual |
Manual |
Manual |
|||
| (Vertical) | Manual |
Manual |
Automatic |
||||
| Air Filter | Washable |
Washable |
Washable |
||||
| Operation Sound Hi/Med/Lo dB-A |
Indoor | 40/35/30 |
40/35/30 |
43/39/36 |
|||
| Outdoor | 49 |
49 |
49 |
||||
| Refrigerant Piping | Flare Type |
Flare Type |
Flare Type |
||||
| Refrigerant Piping Length | Max. 50 Ft. |
Max. 50 Ft.. |
Max. 65 Ft. |
||||
| Elevation Difference | Max. 23 Ft. |
Max. 23 Ft. |
Max. 23 Ft. |
||||
| Dimensions & Weight | Indoor |
Outdoor |
Indoor |
Outdoor |
Indoor |
Outdoor |
|
| Height | 13-19/32" |
20-7/8" |
13-19/32" |
20-7/8" |
14-3/16" |
20-7/8" |
|
| Width | 31-1/2" |
29-17/32" |
31-1/2" |
29-17/32" |
38-31/32" |
29-17/32" |
|
| Depth | 7-3/32" |
11-1/32" |
7-3/32" |
11-1/32" |
7-25/32" |
11-1/32" |
|
| Net Weight Lbs. | 24 |
90 |
24 |
90 |
30 |
90 |
|
| Approvals | ETL, ARI, MEA |
ETL, ARI, MEA |
ETL, ARI, MEA |
||||
* Field Installed
Wall Mounted Heat Pumps |
|||||||
| Model No. | 18KHS22 |
24KHS22 |
36KHS32 |
||||
| Unit Model No. | Indoor Unit |
Outdoor Unit |
Indoor Unit |
Outdoor Unit |
Indoor Unit |
Outdoor Unit |
|
KHS1822 |
CH1822 |
KHS2422 |
CH2422 |
KHS3632 |
CH3632 |
||
| Performance & Electrical Ratings |
|
|
|||||
| Capacity BTU/H | Cooling | 16,500/16,000 |
21,000/20,600 |
33,000/32,000 |
|||
| Heating | 18,000/17,600 |
22,800/22,400 |
40,000/39.000 |
||||
| Moisture Removal (High) Pints/H | 5.3/5.2 |
6.2/6.1 |
10.6/10.6 |
||||
| Dry Air Flow (Hi/Med/Low) | 440/380/320 |
540/460/380 |
830/710/590 |
||||
| SEER | 10.0/10.0 |
10.0/10.0 |
10.31/10.5 |
||||
| HSPF | 6.8/6.8 |
6.8/6.8 |
7.6/7.6 |
||||
| Voltage Rating | 230/208 |
230/208 |
230/208 |
||||
| Running Amps | Cooling | 8.1/8.7 |
10.3/10.9 |
14.91/15.5 |
|||
| Heating | 8.1/8.7 |
11.3/12.2 |
17.81/19.1 |
||||
| Power Input | Cooling | 1,810/1,760 |
2,200/2,170 |
3,290/3,120 |
|||
| Heating | 1,810/1,760 |
2,450/2,400 |
3,860/3,810 |
||||
| Back-up Heater KW | 1.8/1.47 |
1.8/1.47 |
|||||
| Maximum Fuse Size Amps | 30 |
40 |
35 |
||||
| Features |
|
|
|||||
| Controls | Microcomputer |
Microcomputer |
Microcomputer |
||||
| Low Ambient Control | * Optional |
Down to 23°F |
Down to 23°F |
||||
| Fan Speeds | 3+ Automatic |
3+ Automatic |
3 + Automatic |
||||
| Timer | On/Off/24-Hour |
On/Off/24-Hour |
On/Off/24-Hour |
||||
| Air Deflection | (Horizontal) | Manual |
Manual |
Manual |
|||
| (Vertical) | Automatic |
Automatic |
Automatic |
||||
| Air Filter | Washable |
Washable |
Washable |
||||
| Operation Sound Hi/Med/Lo dB-A |
Indoor | 47/44/40 |
45/42/40 |
48/44/40 |
|||
| Outdoor | 55 |
52 |
56 |
||||
| Refrigerant Piping | Flare Type |
Flare Type |
Flare Type |
||||
| Refrigerant Piping Length | Max. 65 Ft. |
Max. 100 Ft. |
Max. 165 Ft. |
||||
| Elevation Difference | Max. 23 Ft. |
Max. 50 Ft. |
Max. 100 Ft. |
||||
| Dimensions & Weight | Indoor |
Outdoor |
Indoor |
Outdoor |
Indoor |
Outdoor |
|
| Height | 14-3/16" |
24-13/16" |
14-9/16" |
30-1/8" |
14-9/16" |
48-5/8" |
|
| Width | 38-31/32" |
32-11/16" |
49-7/32" |
26-3/8" |
59-1/16" |
37" |
|
| Depth | 7-25/32" |
12-13/32" |
8-9/32" |
26-3/8" |
9-7/16" |
13-3/8" |
|
| Net Weight Lbs. | 30 |
134 |
44 |
185 |
73 |
203 |
|
| Approvals | ETL, ARI, MEA |
ETL, ARI, MEA |
ELT, ARI, MEA |
||||
* Field Installed