| Search |
|
|
|
| |
| Site Navigation |
|
|
|
| News / Publications |
|
|
|
| Jobs | |
|
|
| Service |
|
|
|
|
|


|
| |
|
| |
Sanyo Air Conditioning Prod. Ductless Air Conditioning and Heat Pump Products Wall-Mounted Heat Pumps-page 3
F E A T U R E S
- 24-Hour ON/OFF Program Timer
- Electric-Resistant Back-up Heater (Except 09KHS21/36KHS32)
- Automatic Defrost Cycle
- Heating/Cooling Automatic Changeover
- Hot Start System
- Self Diagnostic Feature
- Non-Polar Wiring
- Night Set Back
- Auto Louver (Except 09KHS21 & 09KHS22)
| Wall
Mounted Heat Pumps |
| Model No. |
09KHS21 |
09KHS22 |
12KHS32 |
| Unit Model No. |
Indoor Unit |
Outdoor Unit |
Indoor Unit |
Outdoor Unit |
Indoor Unit |
Outdoor Unit |
KHS0921 |
CH0921 |
KHS0922 |
CH0922 |
KHS1232 |
CH1232 |
| Performance
& Electrical Ratings |
|
|
|
| Capacity BTU/H |
Cooling |
9,000 |
9,000/8,800 |
11,700/11,500 |
| Heating |
10,800 |
10,900/10,700 |
13,000/12,700 |
| Moisture Removal (High) Pints/H |
2.2 |
2.2/2.1 |
3.3/3.2 |
| Dry Air Flow (Hi/Med/Low) |
220/190/160 |
220/190/160 |
360/310/260 |
| SEER |
10.0 |
10.0/10.0 |
10.0/10.0 |
| HSPF |
6.8 |
6.8/6.8 |
6.8/6.8 |
| Voltage Rating |
115 |
230/208 |
230/208 |
| Running Amps |
Cooling |
8.2 |
4.5/4.6 |
5.6/5.9 |
| Heating |
8.8 |
4.7/4.8 |
5.2/5.5 |
| Power Input |
Cooling |
930 |
950/930 |
1,210/1,180 |
| Heating |
1,010 |
1,030/980 |
1,170/1,120 |
| Back-up Heater KW |
|
1.0/0.82 |
1.5/1.23 |
| Maximum Fuse Size Amps |
15 |
15 |
20 |
| Features |
|
|
|
| Controls |
Microcomputer |
Microcomputer |
Microcomputer |
| Low Ambient Control |
* Optional |
* Optional |
* Optional |
| Fan Speeds |
3+ Automatic |
3+ Automatic |
3+ Automatic |
| Timer |
On/Off/24-Hour |
On/Off/24-Hour |
On/Off/24-Hour |
| Air Deflection |
(Horizontal) |
Manual |
Manual |
Manual |
| (Vertical) |
Manual |
Manual |
Automatic |
| Air Filter |
Washable |
Washable |
Washable |
Operation Sound
Hi/Med/Lo dB-A |
Indoor |
40/35/30 |
40/35/30 |
43/39/36 |
| Outdoor |
49 |
49 |
49 |
| Refrigerant Piping |
Flare Type
1/4" Discharge
3/8" Suction |
Flare Type
1/4" Discharge
3/8" Suction |
Flare Type
1/4" Discharge
1/2" Suction |
| Refrigerant Piping Length |
Max. 50 Ft. |
Max. 50 Ft.. |
Max. 65 Ft. |
| Elevation Difference |
Max. 23 Ft. |
Max. 23 Ft. |
Max. 23 Ft. |
| Dimensions
& Weight |
Indoor |
Outdoor |
Indoor |
Outdoor |
Indoor |
Outdoor |
| Height |
13-19/32" |
20-7/8" |
13-19/32" |
20-7/8" |
14-3/16" |
20-7/8" |
| Width |
31-1/2" |
29-17/32" |
31-1/2" |
29-17/32" |
38-31/32" |
29-17/32" |
| Depth |
7-3/32" |
11-1/32" |
7-3/32" |
11-1/32" |
7-25/32" |
11-1/32" |
| Net Weight Lbs. |
24 |
90 |
24 |
90 |
30 |
90 |
| Approvals |
ETL, ARI, MEA |
ETL, ARI, MEA |
ETL, ARI, MEA |
* Field Installed
Wall Mounted Heat Pumps |
| Model No.
|
18KHS22
|
24KHS22
|
36KHS32
|
| Unit Model No. |
Indoor Unit |
Outdoor Unit |
Indoor Unit |
Outdoor Unit |
Indoor Unit |
Outdoor Unit |
KHS1822 |
CH1822 |
KHS2422 |
CH2422 |
KHS3632 |
CH3632 |
| Performance
& Electrical Ratings |
|
|
|
| Capacity BTU/H |
Cooling |
16,500/16,000
|
21,000/20,600
|
33,000/32,000
|
| Heating |
18,000/17,600
|
22,800/22,400
|
40,000/39.000
|
| Moisture Removal (High) Pints/H
|
5.3/5.2 |
6.2/6.1 |
10.6/10.6
|
| Dry Air Flow (Hi/Med/Low) |
440/380/320
|
540/460/380
|
830/710/590
|
| SEER |
10.0/10.0
|
10.0/10.0
|
10.31/10.5
|
| HSPF |
6.8/6.8 |
6.8/6.8
|
7.6/7.6 |
| Voltage Rating |
230/208 |
230/208 |
230/208 |
| Running Amps |
Cooling |
8.1/8.7 |
10.3/10.9
|
14.91/15.5
|
| Heating |
8.1/8.7 |
11.3/12.2
|
17.81/19.1
|
| Power Input |
Cooling |
1,810/1,760
|
2,200/2,170
|
3,290/3,120
|
| Heating |
1,810/1,760
|
2,450/2,400
|
3,860/3,810
|
| Back-up Heater KW |
1.8/1.47
|
1.8/1.47
|
|
| Maximum Fuse Size Amps |
30 |
40 |
35 |
| Features
|
|
|
|
| Controls |
Microcomputer
|
Microcomputer
|
Microcomputer
|
| Low Ambient Control |
* Optional
|
Down to 23°F |
Down to 23°F
|
| Fan Speeds |
3+ Automatic
|
3+ Automatic
|
3 + Automatic
|
| Timer |
On/Off/24-Hour
|
On/Off/24-Hour
|
On/Off/24-Hour
|
| Air Deflection |
(Horizontal) |
Manual |
Manual |
Manual |
| (Vertical) |
Automatic
|
Automatic
|
Automatic
|
| Air Filter |
Washable
|
Washable
|
Washable
|
Operation Sound
Hi/Med/Lo dB-A |
Indoor |
47/44/40
|
45/42/40
|
48/44/40
|
| Outdoor |
55 |
52 |
56 |
| Refrigerant Piping |
Flare Type
1/4" Discharge
5/8" Suction |
Flare Type
1/4" Discharge
3/4" Suction |
Flare Type
3/8" Discharge
3/4" Suction |
| Refrigerant Piping Length |
Max. 65 Ft.
|
Max. 100 Ft.
|
Max. 165 Ft.
|
| Elevation Difference |
Max. 23 Ft.
|
Max. 50 Ft.
|
Max. 100 Ft.
|
| Dimensions
& Weight |
Indoor |
Outdoor |
Indoor |
Outdoor |
Indoor |
Outdoor |
| Height |
14-3/16" |
24-13/16" |
14-9/16" |
30-1/8" |
14-9/16" |
48-5/8" |
| Width |
38-31/32" |
32-11/16" |
49-7/32" |
26-3/8" |
59-1/16" |
37" |
| Depth |
7-25/32" |
12-13/32" |
8-9/32" |
26-3/8" |
9-7/16" |
13-3/8" |
| Net Weight Lbs. |
30 |
134 |
44 |
185 |
73 |
203 |
| Approvals
|
ETL, ARI, MEA
|
ETL, ARI, MEA
|
ELT, ARI, MEA
|
* Field Installed
Copyright © 19962008 AECinfo.com
|
|