| Search |
|
|
|
| |
| Site Navigation |
|
|
|
| News / Publications |
|
|
|
| Jobs | |
|
|
| Service |
|
|
|
|
|


|
| |
|
| |
Sanyo Air Conditioning Prod. Ductless Air Conditioning and Heat Pump Products Dual-Zone and Tri-Zone AC and Heat Pumps-page 5
D U A L Z O N E F E A T U R E S
- 2 Independent Systems with 2 Indoor
Evaporators Connected to a Single Outdoor Condenser.
- Electric-Resistant Back-up Heater
(18KMH22)
- Automatic Defrost Cycle
- Hot Start System Ensures Comfortable
Warm Air from the Beginning of the Heating Process
| Dual-Zone
Air Conditioners & Heat Pumps |
| Model No. |
18KMS12 |
18KMH22 |
24KMS12 |
| Unit Model No. |
Indoor Unit |
Outdoor Unit |
Indoor Unit |
Outdoor Unit |
Indoor Unit |
Outdoor Unit |
KMS0912 x 2 |
CM1812 |
KMH0922 x 2 |
CMH1822 |
KMS1212 x 2 |
CM2412 |
| Performance
& Electrical Ratings |
Each System |
Total System |
Each System |
Total System |
Each System |
Total System |
| Capacity BTU/H |
Cooling |
9,000/ 8,800 |
18,000/ 17,600 |
8,800/ 8,700 |
16,800/ 16,300 |
12,800/ 12,500 |
24,000/ 23,500 |
| Heating |
|
|
10,000/9,800 |
19,000/18,000 |
|
|
| Moisture Removal (High) Pints/H |
2.2/2.1 |
4.4/4.2 |
2.2/2.1 |
4.4/4.2 |
3.3/3.2 |
5.6/5.4 |
| Dry Air Flow (Hi/Med/Low) |
220/ 190/ 160 |
440/ 380/ 320 |
220/ 190/ 160 |
440/ 380/ 320 |
360/ 310/ 260 |
720/ 620/ 520 |
| SEER |
10.0/10.0 |
10.0/10.0 |
10.0/10.0 |
10.0/10.0 |
10.0/10.0 |
10.0/10.0 |
| HSPF |
|
|
7.0/7.0 |
7.0/7.0 |
|
|
| Voltage Rating |
230/208 |
230/208 |
230/208 |
230/208 |
230/208 |
230/208 |
| Running Amps |
Cooling |
4.3/4.5 |
8.6/9.0 |
4.1/4.3 |
8.2/8.7 |
5.7/6.0 |
11.2/12.0 |
| Heating |
|
|
4.1/4.3 |
7.5/7.9 |
|
|
| Power Input |
Cooling |
930/ 910 |
1,860/ 1,820 |
900/ 870 |
1,820/ 1,780 |
1280/ 1240 |
2,570/ 2,480 |
| Heating |
|
|
900/ 870 |
1,640/ 1,590 |
|
|
| Back-up Heater KW |
|
|
1.0/0.82 |
2.0/1.64 |
|
|
| Maximum Fuse Size Amps |
15 |
15 |
30 |
30 |
30 |
30 |
| Features |
|
|
|
| Controls |
Microcomputer |
Microcomputer |
Microcomputer |
| Low Ambient Control |
* Optional |
* Optional |
* Optional |
| Fan Speeds |
3+ Automatic |
3+ Automatic |
3+ Automatic |
| Timer |
On/ Off/
24-Hour |
On/ Off/
24-Hour |
On/ Off/
24-Hour |
| Air Deflection |
(Horizontal) |
Manual |
Manual |
Manual |
| (Vertical) |
Manual |
Manual |
Automatic |
| Air Filter |
Washable |
Washable |
Washable |
Operation Sound
Hi/Med/Lo dB-A |
Indoor |
40/35/30 |
40/35/30 |
40/37/34 |
| Outdoor |
54 |
56 |
53 |
| Refrigerant Piping |
Flare Type
1/4" Discharge
3/8" Suction |
Flare Type
1/4" Discharge
3/8" Suction |
Flare Type
1/4" Discharge
1/2" Suction |
| Refrigerant Piping Length |
Max. 50 Ft.
(Each) |
Max. 50 Ft.
(Each) |
Max. 65 Ft.
(Each) |
| Elevation Difference |
Max. 23 Ft. |
Max. 23 Ft. |
Max. 23 Ft. |
| Dimensions
& Weight |
Indoor |
Outdoor |
Indoor |
Outdoor |
Indoor |
Outdoor |
| Height |
13-19/32" |
24-13/16" |
13-19/32" |
24-13/16" |
14-3/16" |
32-7/8" |
| Width |
31-1/2" |
32-11/16" |
31-1/2" |
32-11/16" |
39-3/8" |
33-15/32" |
| Depth |
7-3/32" |
12-13/32" |
7-3/32" |
12-13/32" |
8-3/32" |
12-1/32" |
| Net Weight Lbs. |
24 |
130 |
24 |
134 |
37 |
158 |
| Approvals |
ETL, ARI, MEA |
ETL, ARI, MEA |
ETL, ARI, MEA |
* Field Installed
Copyright © 19962008 AECinfo.com
|
|