Sanyo Air Conditioning Prod.
Ductless Air Conditioning and Heat Pump Products
Ceiling-Suspended AC and Heat Pumps-page 7
Ductless Air Conditioning and Heat Pump Products
![]() |
![]() O U T D O O R U N I T S ![]() ![]() |
F E A T U R E S
- Microcomputer-Controlled System
- Wireless Remote Control
- 24-Hour ON/OFF Program Timer
- Fresh-Air Intake Knockout
- Low Ambient Models
- Night Set Back
- Auto Louver
- Twin Indoor System (48TS22N)
Ceiling-Suspended Air Conditioners |
|||||||
| Model No. | 24TS32/24TLS32 |
36TS32/TLS32 |
48TS22N |
||||
| Unit Model No. | Indoor Unit |
Outdoor Unit |
Indoor Unit |
Outdoor Unit |
Indoor Unit |
Outdoor Unit |
|
TS2432 |
C2432/ CL2432 |
TS3632 |
C3632/ CL3632 |
TS2422A/B |
C4822N |
||
| Performance & Electrical Ratings |
|
|
|
||||
| Capacity BTU/H | Cooling | 24,000/23,400 |
34,000/33,000 |
45,000/44,000 |
|||
| Heating |
|
|
|
||||
| Moisture Removal (High) Pints/H | 7.1/6.9 |
10.6/10.8 |
13.2/12.9 |
||||
| Dry Air Flow (Hi/Med/Low) | 460/400/310 |
900/790/680 |
1,100/955/830 |
||||
| SEER | 10.0/10.0 |
10.6/10.9 |
10.0/10.0 |
||||
| HSPF |
|
|
|
||||
| Voltage Rating | 230/208 |
230/208 |
230/208 |
||||
| Running Amps | Cooling | 11.3/11.9 |
15.0/15.5 |
21.3/21.9 |
|||
| Heating |
|
|
|
||||
| Power Input | Cooling | 2,420/2,360 |
3,340/3,130 |
4,500/4,350 |
|||
| Heating |
|
|
|
||||
| Back-up Heater KW |
|
|
|
||||
| Maximum Fuse Size Amps | 30 |
30 |
60 |
||||
| Features |
|
|
|
||||
| Controls | Microcomputer |
Microcomputer |
Microcomputer |
||||
| Low Ambient Control | 24TS32 * Optional/24TLS32 Equip. |
36TS32 * Optional/36TLS32 Equip. |
* Optional |
||||
| Fan Speeds | 3+ Automatic |
3+ Automatic |
3+ Automatic |
||||
| Timer | On/Off/24-Hour |
On/Off/24-Hour |
On/Off/24-Hour |
||||
| Air Deflection | (Horizontal) | Manual |
Manual |
Manual |
|||
| (Vertical) | Automatic |
Automatic |
Automatic |
||||
| Air Filter | Washable |
Washable |
Washable |
||||
| Operation Sound Hi/Med/Lo dB-A |
Indoor | 39/37/33 |
42/40/35 |
45/41/37 |
|||
| Outdoor | 53 |
56 |
65 |
||||
| Refrigerant Piping | Flare Type |
Flare Type |
Flare Type |
||||
| Refrigerant Piping Length | Max. 132 Ft. |
Max. 165 Ft. |
Max. 130 Ft. |
||||
| Elevation Difference | Max. 83 Ft. |
Max. 100 Ft. |
Max. 50 Ft. |
||||
| Dimensions & Weight | Indoor |
Outdoor |
Indoor |
Outdoor |
Indoor x 2 |
Outdoor |
|
| Height | 7-15/32" |
28-15/16" |
9-7/16" |
48-5/8" |
7-1/4" |
37-5/8" |
|
| Width | 51-3/16" |
37" |
62" |
37" |
50" |
32-9/32" |
|
| Depth | 26-3/8" |
13-3/8" |
26-3/8" |
13-7/8" |
26-3/8" |
32-9/32" |
|
| Net Weight Lbs. | 57 |
150 |
84 |
200 |
62 |
330 |
|
| Approvals | ETL, ARI, MEA |
ETL, ARI, MEA |
ETL, ARI, MEA |
||||
* Field Installed