| Search |
|
|
|
| |
| Site Navigation |
|
|
|
| News / Publications |
|
|
|
| Jobs | |
|
|
| Service |
|
|
|
|
|


|
| |
|
| |
Sanyo Air Conditioning Prod. Ductless Air Conditioning and Heat Pump Products Ceiling-Suspended AC and Heat Pumps-page 8
CEILING SUSPENDED HEAT PUMP
FEATURES
- Electric-Resistant Back-up Heater
- Automatic Defrost Cycle Prevents Coil Freeze-Up
During Heat Pump Operation
- Heating/Cooling Automatic Changeover
- Hot Start System Ensures Comfortable Warm Air from
the Beginning of the Heating Process
- Self Diagnostic Feature Facilities Maintenance &
Repair
- Non-Polar Wiring Simplifies Installation
- Twin Door System for Better Air Circulation
(48THS22N only)
- Refrigerant Charge-Free Operation Up to 100 Ft.
(Except 48THS22N)
- Fuzzy Logic Control Ensuring the Unit operates at
suitable capacity (Except 48THS22N)
Ceiling-Suspended Heat Pumps |
| Model No. |
24THS22 |
36THS22 |
48THS22N |
| Unit Model No. |
Indoor Unit |
Outdoor Unit |
Indoor Unit |
Outdoor Unit |
Indoor Unit |
Outdoor Unit |
THS2422 |
CH2422 |
THS3622 |
CH3622 |
THS2422A/B |
CH4822N |
| Performance
& Electrical Ratings |
|
|
|
| Capacity BTU/H |
Cooling |
22,000/21,400 |
36,000/35,000 |
43,000/42,000 |
| Heating |
23,400/22,800 |
37,000/36,000 |
47,000/46,000 |
| Moisture Removal (High) Pints/H |
6.3/6.2 |
10.4/10.2 |
12.6/12.2 |
| Dry Air Flow (Hi/Med/Low) |
565/490/425 |
950/830/715 |
920/800/690 |
| SEER |
10.0/10.0 |
10.0/10.2 |
10.0/10.0 |
| HSPF |
6.8/6.8 |
7.2/7.2 |
6.8/6.8 |
| Voltage Rating |
230/208 |
230/208 |
230/208 |
| Running Amps |
Cooling |
10.7/11.3 |
17.5/18.3 |
21.0/21.7 |
| Heating |
11.7/12.9 |
16.7/16.6 |
22.6/23.9 |
| Power Input |
Cooling |
2,290/2,250 |
3,650/3,550 |
4,430/4,300 |
| Heating |
2,530/2,480 |
3,450/3,300 |
4,470/4,670 |
| Back-up Heater KW |
1.8/1.47 |
3.0/2.45 |
3.6/2.94 |
| Maximum Fuse Size Amps |
40 |
50 |
60 |
| Features |
|
|
|
| Controls |
Microcomputer |
Microcomputer |
Microcomputer |
| Low Ambient Control |
* Optional |
* Optional |
* Optional |
| Fan Speeds |
3+ Automatic |
3+ Automatic |
3+ Automatic |
| Timer |
On/Off/24-Hour |
On/Off/24-Hour |
On/Off/24-Hour |
| Air Deflection |
(Horizontal) |
Manual |
Manual |
Manual |
| (Vertical) |
Automatic |
Automatic |
Automatic |
| Air Filter |
Washable |
Washable |
Washable |
Operation Sound
Hi/Med/Lo dB-A |
Indoor |
45/41/37 |
47/43/39 |
45/41/37 |
| Outdoor |
52 |
62 |
65 |
| Refrigerant Piping |
Flare Type
1/4" Discharge
3/4" Suction |
Flare Type
3/8" Discharge
3/4" Suction |
Flare Type
3/8" (Main), 1/4" (Branch)
7/8" (Main), 5/8" (Branch) |
| Refrigerant Piping Length |
Max. 100 Ft. |
Max. 130 Ft. |
Max. 130 Ft. |
| Elevation Difference |
Max. 50 Ft. |
Max. 50 Ft. |
Max. 50 Ft. |
| Dimensions
& Weight |
Indoor |
Outdoor |
Indoor |
Outdoor |
Indoor |
Outdoor |
| Height |
7-9/32" |
30-1/8" |
9-27/32" |
38-7/8" |
7-9/32" |
37-5/8" |
| Width |
50" |
26-3/8" |
61-13/16" |
26-3/8" |
50" |
32-9/32" |
| Depth |
26-3/8" |
26-3/8" |
26-3/8" |
26-3/8" |
26-3/8" |
32-9/32" |
| Net Weight Lbs. |
67 |
185 |
98 |
218 |
67 |
345 |
| Approvals |
ETL, ARI, MEA |
ETL, ARI, MEA |
ETL, ARI, MEA |
* Field Installed
Copyright © 19962008 AECinfo.com
|
|