Sanyo Air Conditioning Prod. Ductless Air Conditioning and Heat Pump Products Ceiling-Recessed Air Conditioners-page 9
F E A T U R E S
- Fresh Air Intake Plenum to Have up to 20% of CFM
(Except 12RS/RLS11 and 48RS22N)
- Microcomputer-Controlled System
- Wireless Remote Control
- 24-Hour ON/OFF Program Timer
- 4-Way, 3-Way or 2-Way Air Discharge (Except
12RS/RLS11)
- Built-in Condensate Pump (Except 48RS22N)
- Auto Louver (Except 12RS/RLS11)
- Night Set Back
- Duct Extentension Capability (Except 12RS/RLS11)
- Twin Indoor System (48RS22N)
- ETL, ARI Approved
| Ceiling-Recessed
Air Conditioners |
| Model No. |
12RS11/
12RS11 |
18XLS22 |
24XS32/
24XLS32 |
36XS22 |
48RS22N |
| Unit Model No. |
Indoor Unit |
Outdoor Unit |
Indoor Unit |
Outdoor Unit |
Indoor Unit |
Outdoor Unit |
Indoor Unit |
Outdoor Unit |
Indoor Unit |
Outdoor Unit |
RS1211 |
C1211/ CL1211 |
XS1822 |
CL1822 |
XS2432 |
C2432/ CL2432 |
XS3622 |
C3622/ CL3632 |
RS2422A+B |
C4822 |
| Performance
& Electrical Ratings |
|
|
|
|
|
| Capacity BTU/H |
Cooling |
11,500 |
18,000/17,500 |
24,000/23,400 |
36,000/35,000 |
45,000/44,000 |
| Heating |
|
|
|
|
|
| Moisture Removal (High) Pints/H |
3.1 |
5.5/5.4 |
7.1/6.9 |
11.9/11.9 |
13.2/12.9 |
| Dry Air Flow (Hi/Med/Low) |
280/245/220 |
540/460/360 |
540/460/360 |
980/830/650 |
1,000/980 |
| SEER |
10.0 |
10.4/10.4 |
10.0/10.2 |
10.8/11.0 |
10.0/10.0 |
| HSPF |
|
|
|
|
|
| Voltage Rating |
115 |
230/208 |
230/208 |
230/208 |
230/208 |
| Running Amps |
Cooling |
11.2 |
8.0/8.6 |
11.6/12.2 |
15.4/16.0 |
21.5/22.1 |
| Heating |
|
|
|
|
|
| Power Input |
Cooling |
1,200 |
1,780/1,730 |
2,440/2,380 |
3,440/3,250 |
4,540/4,390 |
| Heating |
|
|
|
|
|
| Back-up Heater KW |
|
|
|
|
|
| Maximum Fuse Size Amps |
15 |
20 |
30 |
30 |
60 |
| Features |
|
|
|
|
|
| Controls |
Microcomputer |
Microcomputer |
Microcomputer |
Microcomputer |
Microcomputer |
| Low Ambient Control |
12XS11Optional/
12XLS11 Equip. |
Equiped |
24XS32Optional/
24XLS32 Equip. |
36XS32Optional/
36XLS32 Equip. |
* Optional |
| Fan Speeds |
3+ Automatic |
3 + Automatic |
3+ Automatic |
3+ Automatic |
3+ Automatic |
| Timer |
On/ Off/
24-Hour |
On/ Off/
24-Hour |
On/ Off/
24-Hour |
On/ Off/
24-Hour |
On/ Off/
24-Hour |
| Air Deflection |
(Horizontal) |
- |
|
- |
- |
- |
| (Vertical) |
Automatic |
Automatic |
Automatic |
Automatic |
Automatic |
| Air Filter |
Washable |
Washable |
Washable |
Washable |
Washable |
Operation Sound
Hi/Med/Lo dB-A |
Indoor |
45/41/37 |
37/35/31 |
37/35/31 |
43/40/36 |
45/41/37 |
| Outdoor |
49 |
55 |
53 |
56 |
65 |
| Refrigerant Piping |
Flare Type
1/4" Discharge
1/2" Suction |
Flare Type
1/4" Discharge
5/8" Suction |
Flare Type
1/4" Discharge
3/4" Suction |
Flare Type
3/8" Discharge
3/4" Suction |
Flare Type
3/8" (Main), 1/4" (Branch)
3/4" (Main), 5/8" (Branch) |
| Refrigerant Piping Length |
Max. 65 Ft. |
Max. 65 Ft. |
Max. 132 Ft. |
Max. 165 Ft. |
Max. 130 Ft. |
| Elevation Difference |
Max. 33 Ft. |
Max. 23 Ft. |
Max. 83 Ft. |
Max. 100 Ft. |
Max. 50 Ft. |
| Dimensions
& Weight |
Indoor |
Outdoor |
Indoor |
Outdoor |
Indoor |
Outdoor |
Indoor |
Outdoor |
Indoor |
Outdoor |
| Height |
12- 5/8" |
20- 7/8" |
9- 27/32" |
24- 13/16" |
9- 27/32" |
28- 15/16" |
11- 1/32" |
48- 5/8" |
17- 5/16" |
37- 5/8" |
| Width |
31- 29/32" |
29- 17/32" |
33- 24/32" |
32- 11/16" |
33 -27/32" |
37" |
45- 9/32" |
37" |
48- 7/32" |
32- 9/32" |
| Depth |
24- 13/32" |
11- 1/32" |
33- 27/32" |
12- 13/32" |
33- 27/32" |
13- 3/8" |
33- 27/32" |
13- 7/8" |
25- 19/32" |
32- 9/32" |
| Net Weight Lbs. |
68 |
90 |
60 |
121 |
60 |
150 |
75 |
200 |
113 |
330 |
| Approvals |
ETL, ARI, MEA |
ETL, ARI, MEA |
ETL, ARI, MEA |
ETL, ARI, MEA |
ETL, ARI, MEA |
* Field Installed