   Schindler Elevator Corp.  Technical Data  

Technical Data - Page 52

 

 

Hatch Plans

Front Opening
Front & Rear Opening
Rear Glass Opening

zsch052a.gif (19016 bytes)

zsch052b.gif (17033 bytes)

FRONT OPENING

Capacity
(lbs.)

Std. Speed (fpm) Maximum Standard Clear Opening & Door System
(ii)
Platform Size Minimum Clear Cab Inside Hoistway
Openings Travel (i) A Width B Depth CA Width CB Depth C (ix) Clear Width D (iv) Wall to Wall
2000 100 8 71'-0" 3'-0" SSSO 6'-0" 5'-1" 5'-8" 4'-3" 7'-4" 5'-9"
125 77'-0"
150 77'-0"
2500 100 8 70'-0" 3'-6" SSSO SSCO 7'-0" 5'-1" 6'-8" 4'-3" 8'-4" 5'-9"
125 76'-0"
150 76'-0"
3000 100 8 70'-0" 3'-6" SSSO SSCO 7'-0" 5'-7" 6'-8" 4'-9" 8'-4" 6'-3"
125 72'-0"
150 73'-0"
3500 100/125/150 8 69'-0" 3'-6" SSSO SSCO 7'-0" 6'-3" 6'-8" 5'-5" 8'-4" 6'-11"
4000 100/125/150 8 66'-0" 4'-0" SSCO 8'-0" 6'-3" 7'-8" 5'-5" 9'-4" 6'-11"
5000 100 8 61'-3" 4'-0"

4'-6"
SSCO 2SSO 8'-4" 7'-0" 8'-0" 6'-2"* 6'- 1/2"** 9'-8"+
10'-1/2"+
7'-8"*
7'-9 1/2"**
125
150
6000 100 8 57'-6" 4'-0" 4'-6" SSCO 2SSO 8'-5" 7'-8" 8'-1" 6'-10"*
6'-8 1/2"** 
9'-9'+
10'-1/2"
8'-4"
8'-5 1/2"**
125 57'-1"
150 57'-1"

 

Capacity
(lbs)
E G J R S
SSSO Doors SSCO Doors 2SSO Doors SSSO Doors SSCO Doors 2SSO Doors
2000 2'-1" 3'-8" 2'-7 1/4" 3'-5" - - 11" - -
2500 2' -1 1/2" 4'-2" 2'-7 3/4" 3'-11' 2'-5" - 11" 2'-5" -
3000 2'-4 1/8' 4'-2" 2'-10 3/8" 3'-11" 2'-5" - 11" 2'-5" -
3500 2'-8 1/8" 4'-2" 3'-2 3/8" 3'-11" 2'-5" - 11" 2'-5" -
4000 2'-8 1/8" 4'-8" 3'-2 3/8" - 2'-8" - - 2'-8" -
5000 3'-1" 4'-10"
5'-1/4"
5'-1/4"
3'-8 1/4"*
3'-9 3/4"
- 2'-10" 2'-9 1/4" 4'-9"
4'-7 1/2"
- 2'-10" 2'-9 1/4" 11"
6000 3'-5" 4'-10 1/2"
5'-1/4"
5'-1/4"
4'-1/4"
4'-1 3/4"**
- 2'-10 1/2" 2'-9 1/4" 4'-10"
4'-7 1/2"
- 2'- 10 1/2" 2'-9 1/4" 11"

 

FRONT & REAR OPENING

Capacity
(lbs)

Std. Speed (fpm) Maximum Standard Clear Opening & Door System
(ii)
Platform Size Minimum Clear Cab Inside Hoistway
Openings Travel (i) A Width B Depth CA Width CB Depth C (ix) Clear Width D (iv) Wall to Wall
2500 100 8 Front
4 Rear
70'-0" 3'-6" SSCO
SSSO
7'-0" 5'-7" 6'-8" 4'-3" 8'-4" 6'-7 1/2"
125 74'-0"
150 74'-0"
3000 100 8 Front
4 Rear
70'-0" 3'-6" SSCO
SSSO
7'-0" 6'-1" 6'-8" 4'-3 1/2" 8'-4" 7'-1/2"
125 74'-0"
150 74'-0"
3500 100/125/150 8 Front
4 Rear
69'-0" 3'-6" SSCO
SSSO
7'-0" 6'-9" 6'-8" 4'-9 1/2" 8'-4"
4000 100/125/150 8 Front
4 Rear
66'-0" 4'-0" SSCO 8'-0" 6'-9" 7'-8" 5'-5 1/2" 9'-4" 7'-9 1/2"
5000 100 8 Front
4 Rear
61'-3" 4'-0"

4'-6"
SSCO 2SSO 8'-4" 7'-4" 8'-0" 6'-1/2"* 5'- 9 1/2"** 9'-8"+
10'-1/2"+
8'-4 1/2"*
8'-7 1/2"**
125
150
6000 100 8 Front
4 Rear
57'-6" 4'-0" 4'-6" SSCO 2SSO 8'-5" 7'-9" 8'-1" 6'-5 1/2"*
6'-2 1/2"** 
9'-9'+
10'-1/2"
8'-9 1/2"
9'- 1/2"**
125 57'-1"
150 57'-1"

 

Capacity
(lbs)
E G J R S
  SSSO Doors SSCO Doors 2SSO Doors SSSO Doors SSCO Doors 2SSO Doors
2500 2' -1 1/2" 4'-2" 2'-7 3/4" 3'-11' 2'-5" - 11" 2'-5" -
3000 2'-4 1/8' 4'-2" 2'-10 3/8" 3'-11" 2'-5" - 11" 2'-5" -
3500 2'-8 1/8" 4'-2" 3'-2 3/8" 3'-11" 2'-5" - 11" 2'-5" -
4000 2'-8 1/8" 4'-8" 3'-2 3/8" - 2'-8" - - 2'-8" -
5000 3'-1" 4'-10"
5'-1/4"
5'-1/4"
3'-8 1/4"*
3'-9 3/4"
- 2'-10" 2'-9 1/4" 4'-9"
4'-7 1/2"
- 2'-10" 2'-9 1/4" 11"
6000 3'-5" 4'-10 1/2"
5'-1/4"
5'-1/4"
4'-1/4"
4'-1 3/4"**
- 2'-10 1/2" 2'-9 1/4" 4'-10"
4'-7 1/2"
- 2'- 10 1/2" 2'-9 1/4" 11"

 

Notes
Dimensions shown are for U.S . applications. For specific requirements in Canada, please consult your local Canadian sales office.

(i) Maximum standard travel based on Cab 125 (8'-0" high), 4'-0" pit and across the line starting. Higher travel may be available under some conditions. (Contact your local sales representative.)
(ii) SSSO and 2SSO doors available with right or left opening.
(iii) Minimum pit depth is 4'-0". On bore hole application, deep pit available upto 16'-8 ". Maximum travel will be decreased one inch for every inch of pit depth above 4'-0".
(iv) Hoistway depth increases 1 1/2" with flush transoms.
(v) Hoist Beams to be removed by others after elevator installation if minimum cab clearance is not be available.
(vi) For maximum rail bracket vertical spacing consult your local sales representative.
(vii) Adequate steel or concrete beam or concrete wall supports are required for rail mounting bracket based on elevator shop drawing loading at each floor per ASME A17.1. Mounting and interface between building and rail bracket to be in agreement between customer and elevator contractor.
(viii) For front & rear openings, maximum standard is limited to eight openings front and four openings rear with a maximum total of eight landings.
(ix) Add 4" for less than 4000 lbs. and 6" for 4000 lbs. and larger in seismic zone 2 or greater.

Key
* Applies to 4'-0" and 4'-6" SSCO doors
** Applies to 4'-0" and 4'-6" 2SSO doors
+ Applies to 4'-0" SSCO and all 2SSO doors
++ Applies to 4'-6" SSCO doors

 

zsch052c.jpg (5445 bytes)

Request for Information / Request a Catalog from Schindler Elevator Corp.
 
 
 
To request more information from Schindler Elevator Corp., please complete the form below.
 
*Name:    
*Email:    
Company:    
*Company type:    
Phone:    
*Address:    
*Request:    
    (* = Mandatory field) 
Please add me to the mailing list for the free monthly e-Newsletter AECnews.  
     






Printable version Bookmark this page Notify a colleague or friend about this pageHome | Terms of Use | Privacy Statement | Link to AECinfo
AECinfo is a member of Docu Group, the world's largest building products information network.



Copyright © 1996–2008 AECinfo.com