Schindler Elevator Corp. Planning Guide Planning Guide - Page 9
- A wide variety of standard and optional features is
available to tailor the system to your specific project, including:
- Automatic Load Weighing Bypass
- Up Peak/ Down Peak
- Earthquake Feature
- Emergency / Standby power
- False Car Call Canceling
- Hospital/ Emergency Service
- Independent Service
- Restricted Access
- Sub-Group Operation
- Out of Service Feature
- A choice of drive systems is available to suit your
building's requirements, including the most advanced Variodyn® ACVF drives and
Trasitronic DC drives. Both offer performance and reliability to meet the most demanding
standards.
- Standard and optional high performance door operators are
available. All feature advanced, closed loop control for smooth, quiet, and reliable
door operation and infra red light curtain door protection for the utmost in passenger
safety. Door systems available including single-speed side and center opening as well as
two-speed side opening.
- Schindler LobbyVision for in-house management and Servitel® remote monitoring are on-line
support systems available to provide a variety of performance monitoring functions.
- Ride quality and performance packages produce smooth and
quiet rides over a complete range of applications. Each elevator system is built to meet
the design parameters established by your building's requirements.
|
Standard Traction Applications
| |
Capacity
(lbs.) |
Speed
(fpm) |
Minimum Clear Cab
Inside |
Hoistway |
P
Pit
Depth
(ii, viii) |
OH
Overhead
(ii ,vii) |
CA
(Width) |
CB
(Depth) |
C
Clear Width
(ii, iii,v, vi, vii, ix) |
D
Clear Depth
(ii, iii, iv, v, vi, ix) |
| GENERAL PURPOSE |
2500 |
350 |
6'-8" |
4'3" |
8'-4" |
6'-71/2" |
5'-0" |
15'-4" |
| 450 |
5'-10" |
16'-0" |
| 500 |
6'-10" |
6'-8" |
18'-3" |
| 700 |
10'-7" |
20'-0" |
| 1000 |
13'-2" |
18'-8" |
| 3000 |
350 |
6'-8" |
4'9" |
8'-4" |
7'-11/2" |
5'-0" |
15'-4" |
| 450 |
5'-10" |
16'-0" |
| 500 |
7'-4" |
6'-8" |
18'-3" |
| 700 |
10'-7" |
20'-0" |
| 1000 |
13'-2" |
18'-8" |
| 3500 |
350 |
6'-8" |
5'5" |
8'-4" |
7'-91/2" |
5'-0" |
15'-4" |
| 450 |
5'-10" |
16'-0" |
| 500 |
8'-0" |
6'-8" |
18'-3" |
| 700 |
10'-7" |
20'-0" |
| 1000 |
13'-2" |
18'-8" |
| 4000 |
350 |
7'-8" |
5'5" |
9'-4" |
7'-91/2" |
5'-0" |
15'-4" |
| 450 |
5'-10" |
16'-0" |
| 500 |
8'-0" |
6'-8" |
18'-3" |
| 700 |
10'-7" |
20'-0" |
| 1000 |
13'-2" |
18'-8" |
| 5000 |
350 |
8'-8" |
5'2" |
10'-8" |
7'-61/2" |
5'-0" |
15'-4" |
| 500 |
7'-9" |
6'-8" |
18'-3" |
| 700 |
10'-7" |
20'-0" |
| 1000 |
13'-2" |
18'-8" |
| HOSPITAL / SERVICE |
4000 |
350 |
5'-8" |
7'-31/2" |
8'-1" |
9'-11/2" |
5'-0" |
17'-1" |
| 450 |
5'-10" |
17'-9" |
| 500 |
6'-8" |
18'-6" |
| 700 |
10'-7" |
20'-3" |
| 4500 |
350 |
5'-8" |
7'-91/2" |
8'-1" |
9'-71/2" |
5'-0" |
17'-1" |
| 450 |
5'-10" |
17'-9" |
| 500 |
6'-8" |
18'-6" |
| 700 |
10'-7" |
20'-3" |
| 5000 |
350 |
5'-8" |
8'-61/2" |
8'-1" |
10'-41/2" |
5'-0" |
17'-1" |
| 500 |
6'-8" |
18'-6" |
| 700 |
10'-7" |
20'-3" |
NOTES:
(i) All of the above dimensions are based on applying 8'-0" high cabs,
7'-0" high doors, and our standard platforms and equipment.
(ii) Elevators with counterweight safety
a. Add 5" to dimension "C" for applications with side counterweight.
b. Add 5" to dimension "D" for applications with rear counterweight.
c. Either pit "P" or overhead dimension "OH" may increase when
counterweight safety is used. Consult Schindler for actual requirements.
(iii) Elevators with Front and Rear Openings
a. Add 1'-0" to dimension "C" for General Purpose elevator.
b. Add 1/2" to dimension "D" for Hospital/Service elevator.
(iv) Elevators with Flush Transoms
a. Add an additional 11/2" to dimension "D"
(v) Elevators with Seismic Provisions
a. For General Purpose elevators increase dimension "C" by 4" for less than
4000 lbs, 6" for 4000 lbs or greater and dimension "D" by 3".
b. For Hospital / Service Elevators increase "C" by 3".
(vi) Hoistaway Tolerances
a. Clear, plumb hoistway, with variations not to exceed 1" at any point in dimensions
"C" and "D" .
(vii) Single car shown. For multi-car banks 4" steel divider beams by others required
between individual hoistways.
(viii) Pit Depth and Overheads.
a. For every inch of cab height exceeding 8'-0" clear, add an inch to the overhead.
b. All pit depths are based on a maximum 1/8" platform recess, whisperflex
compensation, and full stroke buffers for speeds up to and including700 fpm. At 1000
fpm and above, pit overhead dimensions are based on reduced stroke buffers and rope
compensation.
c. Dimension "OH" (Total Overhead) has been based on 4" machine room slab
and recommended machine beam sizes, with machine beams mounted directly below MR slab.
(ix) ADA inside Cab Dimensions
a. Hoistway widths dimension "C" and depths dimension "D" are based on
meeting ADA inside cab with dimensions "CA" and depth dimensions "CB"
requirements with 1/2" decorative panels applied to a steel shell. Thicker decorative
panels will require a wider hoistway. |