SteamWhirl - Installation - Page 5

 

 

swl01a.JPG (35637 bytes)

 

INSTALLATION

Place the unit in a location (attic, vanity closet, etc.) that has access, not more than 40 feet from enclosure.
Install in upright and level position. Do not expose unit to outside weather conditions or freezing temperatures.

PLUMBING:
IMPORTANT.
Do not place a shut-off valve on steam line. Do not use plumbers putty on any water connections.

1. Tap off any existing water supply line. Flush at least 1 gallon of water to clear line--and connect to 1/4" compression water inlet fitting (A) on unit. When tightening this fitting, use two wrenches to avoid strain on the fitting (A) and solenoid valve (inside unit). Install a shut-off valve (B) on copper supply line as close to unit as possible. Do not use a saddle fitting.

2. Connect 1/2" copper tubing or 1/2" NPT pipe to steam outlet (C) and run to approximately 8" to 12" off finished floor in shower or just above deck of bathtub on any wall not interfering with user. A union may be installed close to the unit to facilitate easy removal if necessary. Avoid valleys and dips where water from steam condensation in the line could collect and cause blockage. Leave approximately 1/2" of threads protruding from finished wall. Place escutcheon on threads and screw on steamhead (D). Rotate steamhead until open slot is facing down.

3. Pressure relief valve (E) to drain to approved location. Install union to facilitate easy removal.

ELECTRIC:

IMPORTANT.- All wiring should be done by a qualified electrician and must conform to all local and national codes.

1. Supply wiring should be sized in accordance with the voltage, amps and phase of the unit (see electrical rating on identification label) and suitable for 900°c. A separate circuit breaker (see chart) should be provided. Bring incoming electrical supply wires to Ll and L2 and the ground to the ground terminal. incoming electrical supply wires to Ll and L2 and the ground to the ground terminal.

2. Install timer (F) in compliance with local and national code. Timer may be installed inside enclosure or out. From the unit, run supplied telephone modular cable and connect to phone jack on timer. DO NOT STAPLE TELEPHONE CORD.

A bead of silicone RTV (supplied by factory) must be applied to the back of the faceplate gasket.
When timer plate is in place, run a bead of silicone on the outer rim of the plate.
Should it become necessary to remove the faceplate decal, clean all residual adhesive using "isopropyl alcohol".
Decal must be placed on timer.

swl04a.JPG (33118 bytes)

START- UP:

1 . After connections are completed, make sure power and water are on by looking through the cutout on drop panel. Lit green light verifies electrical power. The red light will remain lit only if there is an inadequate flow of water to the unit.

2. Timer can be turned off manually before time has elapsed.

swl04b.JPG (20577 bytes)

 

swl02c.JPG (17213 bytes)swl02e.JPG (9299 bytes)
3251 Corte Malpaso • Unit 502
Camarillo, CA. 93010
Telephone (805) 987 - 7957
(800) 232 - STEAM
Fax (805) 987 - 8067
http://www.steam-whirl.com
swsales@steam-whirl.com

A Division of Active Water Systems, Inc.

Request for Information / Request a Catalog from Steam-Whirl
 
 
 
To request more information from Steam-Whirl, please complete the form below.
 
*Name:    
*Email:    
Company:    
*Company type:    
Phone:    
*Address:    
*Request:    
    (* = Mandatory field) 
Please add me to the mailing list for the free monthly e-Newsletter AECnews.  
     






Printable version Bookmark this page Notify a colleague or friend about this pageHome | Terms of Use | Privacy Statement | Link to AECinfo
AECinfo is a member of Docu Group, the world's largest building products information network.



Copyright © 1996–2008 AECinfo.com