Place the unit in a
location (attic, vanity closet, etc.) that has access, not more than 40 feet from
enclosure.
Install in upright and level position. Do not expose unit to outside weather
conditions or freezing temperatures.
PLUMBING:
IMPORTANT. Do not place a shut-off valve on steam line. Do not use plumbers
putty on any water connections.
1. Tap off any existing water supply line.
Flush at least 1 gallon of water to clear line--and connect to 1/4" compression water
inlet fitting (A) on unit. When tightening this fitting, use two wrenches to avoid
strain on the fitting (A) and solenoid valve (inside unit). Install a shut-off
valve (B) on copper supply line as close to unit as possible. Do not use a saddle
fitting.
2. Connect 1/2" copper tubing or 1/2" NPT
pipe to steam outlet (C) and run to approximately 8" to 12" off finished
floor in shower or just above deck of bathtub on any wall not interfering with user. A
union may be installed close to the unit to facilitate easy removal if necessary. Avoid
valleys and dips where water from steam condensation in the line could collect and cause
blockage. Leave approximately 1/2" of threads protruding from finished wall. Place
escutcheon on threads and screw on steamhead (D). Rotate steamhead until open slot
is facing down.
3. Pressure relief valve (E) to drain to
approved location. Install union to facilitate easy removal.
ELECTRIC:
IMPORTANT.- All wiring should be done by a
qualified electrician and must conform to all local and national codes.
1. Supply wiring should be sized in
accordance with the voltage, amps and phase of the unit (see electrical rating on
identification label) and suitable for 900°c. A separate circuit breaker (see chart)
should be provided. Bring incoming electrical supply wires to Ll and L2 and the ground to
the ground terminal. incoming electrical supply wires to Ll and L2 and the ground to the
ground terminal.
2. Install timer (F) in compliance with local
and national code. Timer may be installed inside enclosure or out. From the unit, run
supplied telephone modular cable and connect to phone jack on timer. DO NOT STAPLE
TELEPHONE CORD.
A bead of silicone RTV (supplied by factory) must be
applied to the back of the faceplate gasket.
When timer plate is in place, run a bead of silicone on the outer rim of the plate.
Should it become necessary to remove the faceplate decal, clean all residual adhesive
using "isopropyl alcohol".
Decal must be placed on timer.
START- UP:
1 . After connections are completed, make sure power
and water are on by looking through the cutout on drop panel. Lit green light verifies
electrical power. The red light will remain lit only if there is an inadequate flow of
water to the unit.
2. Timer can be turned off manually before time has
elapsed.
|