Typical Details
Here's
what you do.
|
|
| 1. |
Level concrete slab (or similar) for fountain
foundation. |
| 2. |
30" square excavated hole for utility
stub outs located to bisect perimeter of fountain. |
| 3. |
Run water and drain plumbing from source at
site to excavated hole. (Specified depth per local code) |
| 4. |
Run conduit and electric wires from site
breaker panel to excavated hole. |
| 5. |
Breaker specified by STONEWEAR installed by licensed
electrician. |
| 6. |
Install STONEWEAR timer controls and light transformer by licensed electrician. |
|

 |
Here's
What we do
|
- Provide quotation including freight to
fountain installation site.
- Provide complete fountain including:
|
| 7. |
Basin, center feature, pump(s), lights,
plumbing, control valves, and electrical circuits. |
| 8. |
Pre-plumbed fountain basin with valves for
water input and drain plumbing to common site in fountain bottom. |
| 9. |
Fountain basin electrical reassembled with
waterproof junction boxes to common site in the fountain bottom. |
| 10. |
Specify wire and conduit sizes. |
| 11. |
Provide GFI protected timer controls for pump(s), lights, and transformer. |
|
Fountain Component
Descriptions
- PUMP(S): Submersible pump(s) installed inside fountain basin.
certified.
- LIGHTS: Sealed submersible lights with extra cord length to allow
extraction from water to replace bulbs. 12 volt. UL listed.
- CONTROLS: Two timers, 7-day/24 hour (pump and lights). NEMA 3
enclosure. GFI protection each component. UL listed.
- WATER FEATURES: Adjustable flow to separate elements in water
feature. Built-in chemical feeder using chlorine or bromine tablets.
- PLUMBING: High level overflow drain. Manual main drain. Manual water
fill. Automatic water level control. Feature control valves.
- DOCUMENTATION: Operation manual. Illustrated installation
instructions. Specific site plan specifications. Plumbing and electrical schematics.
Component data sheets.
- PLACEMENT/HOISTING: Easy to move with removable 'lifting eyes'.
- CAST STONE: Proprietary compound of graded stone, cement, and
alkaline-resistant glass fiber.
*Note: STONEWEAR
reserves the right to change any specifications without notice.
Major Component
Locations
- Utility access panels
- Valve to control each element in water feature.
- All utilities connect in this area.
- Utilities from site.
- Make connections and fill hole.
- Stainless steel threaded embed for pick up eye.
- Proprietary STONEWEAR cast
stone, typical.
- Submersible pumps, typical.
- Lights in niche mounts, typical
- Concrete slab foundation. 1 : 2.5 : 5
NOTE: Timer controls located at
site breaker panel.

What does this mean?
The Canadian Standards Association (CSA) has certified
the product.
So what I live in Kansas. Under the CSA symbol you will notice the letters "NRTL/C".
This indicate that the product was tested to meet U.S. standards as well as Canadian
standards.
On December 24, 1992, CSA's Rexdale (Toronto) facility
was officially accredited by the U.S. Occupational Safety and Health Administration
(OSHA), as a Nationally Recognized Testing Laboratory (NRTL). The CSA's accreditation
covers testing and certification to over 360 ANSI/UL Standards for a wide
range of electrical, electronic and other products which require testing or certification
by a NRTL, in accordance with OSHA regulations.
Click here to go to the STONEWEAR home page.
© 1997, 1998, 1999 STONEWEAR
2900 LOCKHEED WAY, CARSON CITY, NV 89706 | 775-883-8300 |