Sub-Zero Design Guide Design Guide - Page 23

|
700 SERIES
PLANNING INFORMATION |
CAUTION |
|
| When 5/8-inch or larger panels
are used and a reveal less than 1/4-inch is maintained, the door panels may cause damage
to the Sub-Zero unit when the door is open at the maximum 105 degree stop. You should use
the built-in 90 degree stop to prevent damage. SPECIAL
NOTE: In an installation where you are placing two 700 Series tall units next to one
another and providing a 1/4-inch reveal, refer to illustration 8, you cannot assume the
panel size is 26-1/2 inches as shown on the top. The panels will need to be 26-5/8 inches
to ensure a consistent 1/4-inch reveal. |

Installation Options
Illustration 9 shows some typical installations and their
dimension considerations.
IMPORTANT NOTE: The front of the Sub-Zero 700 Series Unit
is 24 inches from the back wall. Your design may necessitate moving the unit back, or
cabinets forward to a flush fit.

Illus.9



|

|

|