| Dimensional Data Table DD-3 Machine Dimensions ABTF- 575,660,750
English
| Dimension |
ABTF-575, 660, 750 |
| A |
9- 6- 7 /8" |
| B |
5- 4- 1 /8" |
| C |
5- 8- 3 /4" |
| D |
1-8" |
| E |
3-1" |
| F |
5- 10 - 3/4" |
| G |
7- 2 - 5 /8" |
| X |
9- 5 - 7 /8" |
| J |
8- 6 - 3 /8" |
| K |
6 - 3 - 1 /2" |
| L |
4-9" |
| M |
3-1" |
| N |
1-8" |
| O |
11 -1 /4" |
| P |
3 - 5 /8" |
| Z |
2 - 6 - 7 /8" |
| R |
5 - 4 - 1 /8" |
| S |
7- 11 - 5 /8" |
| T |
3 /4" |
| U |
3 - 4- 1 /2" |
| V |
8- 0 - 7 /8" |
| AA |
30 - 11 - 1 /4" |
| BB |
27- 0" |
| CC |
1-7 - 3/8" |
| DD |
26 - 10 - 3 /4" |
| EE |
11 - 1/4" |
| FF |
1 - 7- 3 /8" |
| GG |
18- 9 - 1 /4" |
| HH |
3 - 5 - 7 /8" |
| JJ |
7" |
| KK |
20 - 3" |
| LL |
3 - 6" |
| MM |
3 - 7 - 1 /8" |
| NN |
5 -1 /4" |
| OO |
1 -7 - 3 /8" |
| PP |
4 - 6" |
| RR |
1-1 - 5 /8" |
SS |
2 - 2 - 3 /8" |
Table DD-4 Machine Dimensions ABTF-
575,660,750 SI (mm)
| Dimension |
ABTF-575, 660, 750 |
| A |
2918 |
| B |
1629 |
| C |
1749 |
| D |
508 |
| E |
940 |
| F |
1797 |
| G |
2200 |
| X |
2892 |
| J |
2600 |
| K |
1918 |
| L |
1448 |
| M |
940 |
| N |
508 |
| O |
286 |
| P |
92 |
| Z |
784 |
| R |
1629 |
| S |
2429 |
| T |
19 |
| U |
1022 |
| V |
2461 |
| AA |
9430 |
| BB |
8230 |
| CC |
492 |
| DD |
8198 |
| EE |
286 |
| FF |
492 |
| GG |
5721 |
| HH |
1064 |
| JJ |
1778 |
| KK |
6172 |
| LL |
1067 |
| MM |
1096 |
| NN |
133 |
| OO |
492 |
| PP |
1372 |
| RR |
346 |
| SS |
670 |
Customer Notes:
1. Front of unit is determined by facing unit control panel
2. All vertical dimensions include 5 /16" thick
isolation pads.
3. Dimensions shown are calculated values.
4. Evaporator connections are 8" and absorber
condenser water connections are for 10" pipe. Available with 150#
grooved connection for use with style 77 Victaulic
coupling. Also, available with 150# American Standard raised face flange (flange bolt
holes straddle vertical centerline).
5. High temperature generator steam inlet connection is for
2" pipe. Provided with 150# American raised face flange (flange bolt holes straddle
vertical centerline).
6. All water box vents are 1 /4" NPT and drains are 3
/4 NPT.
7. Flexible connection must be used for attachment to
rupture disk. Do not apply more than 12 PSI internal pressure on machine without removing
rupture disc. Pipe rupture disc to floor vent or to the outside to meet local code.
8. Field piping must be arranged and supported to avoid
stress on the equipment. It is strongly recommended that the piping contractor refrain
from pre-piping closer than 36" minimum to the equipment. This will allow for proper
connection upon arrival of the unit at the job site. Necessary adjustments can be made at
that time. |