| Dimensional Data
Table DD-5 Machine Dimensions
ABTF-850,950,1050,1150 English
| Dimension |
850 |
950 |
1050 |
1150 |
| A |
11-10-5/8" |
11-10-5/8" |
11-10-5/8" |
11-10-5/8" |
| B |
5-10-1/2" |
5-10-1/2" |
5-10-1/2" |
5-10-1/2" |
| C |
7-8-3/4" |
7-8-3/4" |
7-8-3/4" |
7-8-3/4" |
| D |
2-2-1/8" |
2-2-1/8" |
2-2-1/8" |
2-2-1/8" |
| E |
3-9-7/8" |
3-9-7/8" |
3-9-7/8" |
3-9-7/8" |
| F |
6-4-1/8" |
6-4-1/8" |
6-4-1/8" |
6-4-1/8" |
| G |
9-1-7/8" |
9-1-7/8" |
9-1-7/8" |
9-1-7/8" |
| J |
10-2-1/4" |
10-2-1/4" |
10-2-1/4" |
10-2-1/4" |
| K |
7-10-1/2" |
7-10-1/2" |
7-10-1/2" |
7-10-1/2" |
| L |
6 |
6 |
6 |
6 |
| M |
3-9-7/8" |
3-9-7/8" |
3-9-7/8" |
3-9-7/8" |
| N |
2-2-1/8" |
2-2-1/8" |
2-2-1/8" |
2-2-1/8" |
| O |
1-3-1/8" |
1-3-1/8" |
1-3-1/8" |
1-3-1/8" |
| R |
6-9-5/8" |
6-9-5/8" |
6-9-5/8" |
6-9-5/8" |
| S |
4-9" |
4-9" |
4-9" |
4-9" |
| U |
4-11-1/8" |
4-11-1/8" |
4-11-1/8" |
4-11-1/8" |
| V |
10-9-1/8" |
10-9-1/8" |
10-9-1/8" |
10-9-1/8" |
| X |
11-9-5/8" |
11-9-5/8" |
11-9-5/8" |
11-9-5/8" |
| Z |
3-1-1/2" |
3-1-1/2" |
3-1-1/2" |
3-1-1/2" |
| AA |
23-10-5/8" |
25-10-5/8" |
27-10-5/8" |
29-10-5/8" |
| BB |
20 |
22 |
24 |
26 |
| CC |
9 |
9 |
9 |
9 |
| DD |
20-3-1/4" |
22-3-1/4" |
24-3-1/4" |
26-3-1/4" |
| EE |
9-1/4" |
9-1/4" |
9-1/4" |
9-1/4" |
| FF |
1-9-7/8" |
1-9-7/8" |
1-9-7/8" |
1-9-7/8" |
| GG |
7-6" |
9-6" |
11-6" |
13-6" |
| HH |
4-5" |
4-5" |
4-5" |
4-5" |
| JJ |
2-9-1/4" |
2-9-1/4" |
2-9-1/4" |
2-9-1/4" |
| KK |
14-10" |
16-10" |
18-10" |
20-10" |
| LL |
3-6" |
3-6" |
3-6" |
3-6" |
| MM |
3-4-3/8" |
3-4-3/8" |
3-4-3/8" |
3-4-3/8" |
| NN |
3-1/4" |
3-1/4" |
3-1/4" |
3-1/4" |
| OO |
1-11-5/8" |
1-11-5/8" |
1-11-5/8" |
1-11-5/8" |
| PP |
4-6" |
4-6" |
4-6" |
4-6" |
| RR |
9-5/8" |
9-5/8" |
9-5/8" |
9-5/8" |
| SS |
1-11" |
1-11" |
1-11" |
1-11" |
Table DD-6 Machine Dimensions
ABTF-850,950,1050,1150 SI (mm)
Dimension |
850 |
950 |
1050 |
1150 |
A |
3623 |
3623 |
3623 |
3623 |
B |
1791 |
1791 |
1791 |
1791 |
C |
2356 |
2356 |
2356 |
2356 |
D |
664 |
664 |
664 |
664 |
E |
1165 |
1165 |
1165 |
1165 |
F |
1934 |
1934 |
1934 |
1934 |
G |
2791 |
2791 |
2791 |
2791 |
J |
3105 |
3105 |
3105 |
3105 |
K |
2400 |
2400 |
2400 |
2400 |
L |
1829 |
1829 |
1829 |
1829 |
M |
1165 |
1165 |
1165 |
1165 |
N |
664 |
664 |
664 |
664 |
O |
384 |
384 |
384 |
384 |
R |
2073 |
2073 |
2073 |
2073 |
S |
1448 |
1448 |
1448 |
1448 |
U |
1502 |
1502 |
1502 |
1502 |
V |
3280 |
3280 |
3280 |
3280 |
X |
3597 |
3597 |
3597 |
3597 |
Z |
953 |
953 |
953 |
953 |
AA |
7280 |
7890 |
8499 |
9109 |
BB |
6096 |
6706 |
7315 |
7925 |
CC |
229 |
229 |
229 |
229 |
DD |
6179 |
6788 |
7398 |
8007 |
EE |
235 |
235 |
235 |
235 |
FF |
556 |
556 |
556 |
556 |
GG |
2286 |
2896 |
3505 |
4115 |
HH |
1346 |
1346 |
1346 |
1346 |
JJ |
845 |
845 |
845 |
845 |
KK |
4521 |
5131 |
5740 |
6350 |
LL |
1067 |
1067 |
1067 |
1067 |
MM |
1026 |
1026 |
1026 |
1026 |
NN |
83 |
83 |
83 |
83 |
OO |
600 |
600 |
600 |
600 |
PP |
1372 |
1372 |
1372 |
1372 |
RR |
244 |
244 |
244 |
244 |
SS |
584 |
584 |
584 |
584 |
Customer Notes:
1. Front of unit is determined by facing unit control panel
2. All vertical dimensions include 5 /16" (8 mm) thick
isolation pads.
3. Dimensions shown are calculated values.
4. Evaporator and absorber connections are for 12"
(305 mm) pipe. Available with 150# (10 kg/cm 2 ) grooved conn for use with style 77
victaulic coupling. Also available with 150# (10 kg/cm 2 ) American Standard raised face
flange (flange bolt holes straddle vertical centerline).
5. High temperature generator steam inlet connection is for
2" (305 mm) pipe. Provided with 150# American raised face flange (flange bolt holes
straddle vertical centerline). Condensate return connection is for 1 1 /2" NPS. Both
connections are to be welded.
6. All water box vents are 1 /4" (6 mm) NPT and drains
are 3 /4" (19 mm) NPT.
7. Flexible connection must be used for attachment to
rupture disk. Do not apply more than 12 PSI (.8 kg/cm 2 ) internal pressure on machine
without removing rupture disc. Pipe rupture disc to floor vent or to the outside to meet
local code.
8. Field piping must be arranged and supported to avoid
stress on the equipment. It is strongly recommended that the piping contractor refrain
from pre-piping closer than 36" (914 mm) minimum to the equipment. This will allow
for proper connection upon arrival of the unit at the job site. Necessary adjustments can
be made at that time. |