CGA 120 B 3 00 B A 123 456 7 8 9,10 11 12 DIGIT 1,2,3 Unit Type CGA = Air-Cooled Cold Generator® DIGITS 4,5,6 Nominal Capacity(MBh) 100 = 8 Tons (50 Hz Model only) 120 = 10 Tons (60 Hz Model only) 150 = 12.5 Tons (50 Hz Model Only) 180 = 15 Tons (60 Hz Model Only) DIGIT 7 Major Design Change (Number of Refrigerant Circuits/Number of Compressors) B = 2 Refrigerant Circuits/2 Compressors DIGIT 8 Voltage 1 = 208-230/60/1 (Available CGA120 Only) 3 = 208-230/60/3 4 = 460/60/3 W= 575/60/3 D = 380-415/50/3 DIGIT 9 Factory Installed Options 0 = No Options H = Hot Gas Bypass C = Black Epoxy Coil Standard Deviation K = Hot Gas Bypass & Black Epoxy Coil S = Special DIGIT 10 Leaving Solution Setpoint
DIGIT 11 Minor Design Change A = First, B = Second, etc. DIGIT 12 Service Digit 20, 60 Tons CG A F
C40 4 A A
A 1 A DIGIT 1,2 Unit Model CG = IntelliPak® Air-Cooled Chiller DIGIT 3 Unit Type A = Air-Cooled Condensing DIGIT 4 Development Sequence F = Sixth DIGIT 5,6,7 Nominal Capacity C20 = 20 Tons C25 = 25 Tons C30 = 30 Tons C40 = 40 Tons C50 = 50 Tons C60 = 60 Tons DIGIT 8 Voltage & Start Characteristics E = 200/60/3 XL F = 230/60/3 XL 4 = 460/60/3 XL 5 = 575/60/3 XL 9 = 380/50/3 XL D = 415/50/3 XL S = Special DIGIT 9 Factory Input A = Standard DIGIT 10 Design Sequence A = First B = Second Etc... DIGIT 11 Leaving Solution Setpoint A = 40-50 Deg. F w/o Ice Machine B = 30-39 Deg. F w/o Ice Machine D = 51-65 Deg. F w/o Ice Machine E = 20-29 Deg. F w/o Ice Machine 1 = 40-50 Deg. F with Ice Machine 2 = 30-39 Deg. F with Ice Machine 3 = 51-65 Deg. F with Ice Machine 4 = 20-29 Deg. F with Ice Machine S = Special DIGIT 12 Agency Approval 1 = UL/CSA 0 = None DIGIT 13 Miscellaneous A = Trane Communication Interface (TCI) Module B = No Unit Heat Tape (50 Hz Only) C = Compressor Current Sensing (CSM) D = Unit Mounted Disconnect Switch Nonfused E = Unit Isolators Neoprene F = Unit Isolators Spring G = Superheat/Sub-Cooling H = Hot Gas Bypass J = Generic B A S Module (0-5 v Input, Binary Output) M = Remote Human Interface N = Generic B A S Module (0-10 v Analog) P = Remote Setpoint Potentiometer Q = Zone Sensor Chilled Solution Reset R = Phase/Voltage Monitoring T = Flow Switch V = Copper Fin Condenser Coils W= Electronic Low Ambient Damper(s) Y = Inter-Processor Communication Bridge (IPCB) 9 = Packed Stock Unit The following items can be ordered for separate shipment Unit Isolators Neoprene* Unit Isolators Spring* Flow Switch Electronic Low Ambient Damper(s) Trane Communication Interface Module (TCI) Generic B A S Module (GBAS) (0-5 volt Analog Input/Binary Output) Generic B A S Module (GBAS) (0-10 volt Analog Input/Output) Remote Human Interface Remote Setpoint Potentiometer Zone Sensor (Chilled Solution Reset) Inter-Processor Communication Bridge (IPCB) *Unit size must be specified when ordering this item. |