   Trane Company (The)  Air Cooled Liquid Chillers  

Air Cooled Liquid Chillers - Page 8

 

 

General Data

Table 9-1 - General Data - 10 -60 Ton Units

  10 Ton 15 Ton 20 Ton 25 Ton 30 Ton 40 Ton 50 Ton 60 Ton
Model Number CGA 120 CGA 180 CGAF-C20 CGAF-C25 CGAF-C30 CGAF-C40 CGAF-C50 CGAF-C60
Compressor Data                
 Model Climatuff TraneH Scroll Scroll Scroll Scroll Scroll Scroll
 Quantity 2 2 2 1/1 2 4 2/2 4
Nominal Tons per Compressor 5 7.5 10 10/15 15 10 10/15 15
Evaporator                
Nominal Size (Tons) 10 15 20 25 30 40 50 60
Water Storage Capacity (Gallons)3 1.4 1.5 11.7 10.7 16.3 13.8 21.0 37.8
Min. Flow Rate (GPM) 12.0 18.0 24 30 36 48 60 72
Max. Flow Rate (GPM) 36.0 54.0 72 90 108 144 180 216
Max EWT At Start-Up -- Deg F3 100 100 108 108 108 108 108 108
Condensor                
Nominal Size (Tons) 10 15 20 25 30 40 50 60
Number of Coils 1 2 1 2 2 2 2 2
Coil Size (ea., Inches) 28 x 108 28 x 83 61 x 71 45 x 71/35 x 71 56 x 70 56 x 70 57 x 96 57 x 96
Number of Rows 2 2 3 3 3 3 3 4
Subcooler Size (ea., Inches) 4 x 108 4 x 83 10 x 71 14 x 71 9 x 70 9 x 70 9 x 96 9 x 96
Condensor Fans                
Quantity 1 2 2 3 4 4 6 6
Diameter (Inches) 28 26 26 26 26 26 26 26
CFM (Total) 8,120 11,600 15,000 21,650 29,200 29,200 42,300 40,700
Nominal RPM 1100 1100 1140 1140 1140 1140 1140 1140
Tip Speed (Ft/Min) 8060 7490 7750 7750 7750 7750 7750 7750
Motor HP (ea.) 1 1/2 1.0 1.0 1.0 1.0 1.0 1.0
Drive Type Direct Direct Direct Direct Direct Direct Direct Direct
Minimum Outdoor Air-Temperature Permissible For Mechanical Cooling1                
Standard Ambient Control Unit (°F) 50 45 30 30 30 30 30 30
Standard Ambient w/Hot Gas Bypass (°F) 60 60 40 40 40 40 40 40
Low Ambient Option (°F) 0 0 0 0 0 0 0 0
Low Ambient Control w/HotGas Bypass (°F) 15 15 10 10 10 10 10 10
General Unit                
Unload Steps 100-50 100-50 100-50 100-60-40 100-50 100-75-50-25 100-80-60-30 100-75-50-50-25
No. of Independent Refrig. Circuits 2 2 1 1 1 2 2 2
Refreigerant Charge (lbs. R22/Circuit) 9.5 12.4 40.5 54.0 72.0 38.0 47.0 67.0
Oil Charge (Pints/Circuit) 4.2 7.5 8.0 8.0/14.0 14.0 8.0 8.0/14.0 14.0

*Unloading steps depend upon which compressor is lead compressor.

Notes:

(1) Minimum start-up ambient based on unit a minimum step of unloading and a 5 mph wind across the condensor.

(2) Includes piping internal to chiller.

(3) At 95°F ambient.

(4) Does not include subcooling portion of coil.

Request for Information / Request a Catalog from Trane Company (The)
 
 
 
To request more information from Trane Company (The), please complete the form below.
 
*Name:    
*Email:    
Company:    
*Company type:    
Phone:    
*Address:    
*Request:    
    (* = Mandatory field) 
Please add me to the mailing list for the free monthly e-Newsletter AECnews.  
     






Printable version Bookmark this page Notify a colleague or friend about this pageHome | Terms of Use | Privacy Statement | Link to AECinfo
AECinfo is a member of Docu Group, the world's largest building products information network.



Copyright © 1996–2009 AECinfo.com