| Unit Sizes
Size 10 
| |
|
H = 34 |
Weights |
| |
|
W = 60 |
Single |
Double |
| |
Module |
L |
Wall |
Wall |
| A |
Intake Module |
15-1/2 |
187 |
210 |
| B |
Traq Dampe rMixing Box |
34 |
325 |
389 |
| C |
Mixing/Filter-Mixing Box |
34 |
325 |
389 |
| D |
Economizer |
34 |
325 |
389 |
| E |
Air Blender |
49-1/2 |
299 |
393 |
| F |
Open Return Filter |
4 |
25 |
25 |
| G |
Flat Filter |
11 |
113 |
134 |
| H |
Angled Filter |
24-1/2 |
161 |
198 |
| I |
Bag Filter |
34 |
216 |
280 |
| J |
Cartridge Filter |
24-1/2 |
173 |
210 |
| K |
Small Inspection or Blank |
11 |
87 |
108 |
| L |
Medium Access or Blank |
15-1/2 |
104 |
134 |
| M |
Medium Large Access or Blank |
24-1/2 |
129 |
166 |
| N |
Large Access or Blank |
34 |
172 |
236 |
| O |
Extra Large Access or Blank |
34 |
172 |
236 |
| P |
Turning or Vertical Blank |
34 |
172 |
411 |
| Q |
Small Horizontal Coil |
11 |
94 |
115 |
| R |
Medium Horizontal Coil |
15-1/2 |
112 |
142 |
| S |
Medium Large Horizontal |
24-1/2 |
125 |
188 |
| T |
Large Horizontal Coil |
34 |
194 |
258 |
| U |
Vertical Coil |
34 |
172 |
411 |
| V |
Coil w/Access |
24-1/2 |
540 |
603 |
| W |
Moisture Eliminator |
11 |
163 |
184 |
| X |
External Face and Bypass |
15-1/2
H = 39 |
211 |
241 |
| Y |
Internal Face and Bypass |
15-1/2 |
184 |
214 |
| Z |
Face Damper |
15-1/2 |
183 |
213 |
| AA |
Horizontal Fan |
34 |
| FC Fan |
514 |
589 |
| BI Fan |
669 |
744 |
| AB |
Diffuser |
15-1/2 |
111 |
141 |
| AC |
Top-Mounted Discharge Plenum |
34 |
N/A |
274 |
| |
H = 34 |
|
| AD |
Front-Mounted Discharge Plenum |
34 |
N/A |
274 |
| AE |
Multizone/Double Duct |
46-1/2 |
485 |
583 |
| |
H = 53 |
|
Fan module weights include largest
ODP motor and IGV when applicable. Coil module weights includes the coil module only, add
coil weights separately.
Table U-20 Coil Data
| |
Area (Ft2) |
Qty-Size |
| 1/2 UnitCoils
UW, UF |
9.64 |
1-27x51 |
| Shipping Coils Full |
8.33 |
1-24x50 |
| Custom |
9.50 |
1-24x57 |
| Modified |
6.25 |
1-18x50 |
| HotDeck |
6.30 |
1-18x50 |
Table U-21 Coil
Availability
| Module Size |
1/2
Unit Coil |
Shipping
Coils |
| Small |
2
Row |
1-2
Row |
| Medium |
2-8
Row |
1-4
Row |
| Medium Large |
|
|
Coil |
N/A |
1-8
Row |
Coil
w/Access |
2-8
Row |
1-4
Row |
| Vertical |
2-8
Row |
1-6
Row |
| Multizone |
|
|
Cold
Deck |
2-8 Row |
1-4 Row |
Hot
Deck |
N/A |
1-2
Row |
Table U-22 1 /2
Unit Coil Water Connection Sizes (Inches)
| |
UW |
| HeaderHeight |
27 |
| Supply |
1-1/2 |
| Return |
1-1/2 |
| Drain&Vent |
3/8 |
Shipping Coil connections are located
on page 64. See pages 64-73 for Refrigerant Coil Connections and
Circuiting.
Table U-23 Filter Data
| |
Area (Ft2) |
Qty-Size |
| 2,4Flat (TA,
permanent, pleated media) |
9.7 |
2-20x25 |
| |
|
1-16x25 |
| Angled (TA, permanent, pleated media) |
13.9 |
4-20x25 |
| Bag/Cartridge |
9.3 |
3-12x24 |
| (65%,85% or 95% Efficiency) |
|
1-20x24 |
Refer to page 78
for filter pressure drops.
Table U-24 Areas
| |
Area (Ft2) |
| Traq Damper Mixing Box, Mixing Box or
Economizer |
|
Traq Damper |
2.77 |
Airfoil Blade Damper |
7.71 |
| Internal Face and Bypass |
|
Face Area |
6.16 |
Bypass Area |
2.05 |
| External Face and Bypass |
|
Face Area |
8.21 |
Bypass Area |
4.11 |
| Face Damper |
8.21 |
| Multizone (per deck) |
4.98 |
| (Max. zones/deck) |
9 |
| Air Blender |
3.86 |
Refer to pages 74-79
for pressure drops. See Table P-14 on page 79 for damper torque
requirements. |