| Unit Sizes
Size 12 
|
|
H = 38 |
Weights |
|
|
W = 64 |
Single |
Double |
|
Module |
L |
Wall |
Wall |
| A |
Intake Module |
15-1/2 |
208 |
235 |
| B |
Traq Damper
Mixing Box |
34 |
349 |
419 |
| C |
Mixing/Filter-Mixing
Box |
34 |
349 |
419 |
| D |
Economizer |
34 |
349 |
419 |
| E |
Air Blender |
49-1/2 |
322 |
424 |
| F |
Open Return
Filter |
4 |
25 |
25 |
| G |
Flat Filter |
11 |
120 |
143 |
| H |
Angled Filter |
24-1/2 |
172 |
211 |
| I |
Bag Filter |
38 |
244 |
322 |
| J |
Cartridge Filter |
24-1/2 |
183 |
222 |
| K |
Small
Inspectionor Blank |
11 |
93 |
116 |
| L |
Medium Accessor
Blank |
15-1/2 |
112 |
144 |
| M |
Medium Large
Accessor Blank |
24-1/2 |
138 |
177 |
| N |
Large Accessor
Blank |
34 |
184 |
254 |
| O |
Extra Large
Accessor Blank |
38 |
199 |
277 |
| P |
Turning or
Vertical Blank |
34 |
184 |
441 |
| Q |
Small Horizontal
Coil |
11 |
100 |
123 |
| R |
Medium Horizontal
Coil |
15-1/2 |
119 |
151 |
| S |
Medium Large
Horizontal |
24-1/2 |
125 |
201 |
| T |
Large Horizontal
Coil |
34 |
208 |
278 |
| U |
Vertical Coil |
34 |
184 |
441 |
| V |
Coil w/Access |
24-1/2 |
670 |
746 |
| W |
Moisture
Eliminator |
11 |
184 |
207 |
| X |
External Face and
Bypass |
15-1/2 |
243 |
275 |
|
|
H = 43 |
|
|
| Y |
Internal Face and
Bypass |
15-1/2 |
200 |
232 |
| Z |
Face Damper |
15-1/2 |
215 |
247 |
| AA |
Horizontal Fan |
38 |
|
|
|
|
FC Fan |
595 |
684 |
|
|
BI Fan |
845 |
918 |
|
|
Q-Fan |
|
|
|
|
Q |
642 |
731 |
|
|
R |
766 |
855 |
| AB |
Diffuser |
15-1/2 |
122 |
154 |
| AC |
Top-MountedDischargePlenum |
38
H = 34 |
N/A |
301 |
| AD |
Front-MountedDischargePlenum |
34 |
N/A |
301 |
| AE |
Multizone/DoubleDuct |
65
H = 57 |
634 |
781 |
Fan module weights include largest
ODP motor and IGV when applicable. Coil module weights includes the coil module only, add
coil weights separately.
Table U-26 Coil
Data
| |
Area(Ft2) |
Qty-Size |
1/2 Unit Coils
UW, UU, UF |
12.30 |
1-32x55 |
| 6 Row UU |
11.70 |
1-30x54 |
Shipping Coils
Full |
11.30 |
1-30x54 |
| Custom |
12.70 |
1-30x61 |
| Modified |
9.00 |
1-24x54 |
| Hot Deck |
6.80 |
1-18x54 |
Table U-27
Coil Availability
| Module Size |
1/2 Unit Coil |
Shipping Coils |
| Small |
2 Row |
1-2 Row |
| Medium |
2-8 Row *except 6 Row UU |
1-4 Row |
| Medium Large |
Coil |
6 Row UU |
1-8 Row |
Coil w/Access |
2-8 Row* |
1-4 Row |
| Vertical |
2-8 Row* |
1-6 Row |
| Multizone |
Cold Deck |
2-8 Row* |
1-4 Row |
Hot Deck |
N/A |
1-2 Row |
Table U-28
1 /2 Unit Coil Water Connection Sizes (Inches)
| |
UW/UU |
6 Row UU |
| Header Height |
32 |
30 |
| Supply |
2 |
2-1/2 |
| Return |
2 |
2-1/2 |
| Drain & Vent |
3/8 |
3/8 |
Shipping Coil connections are located
on page 64. See pages 64-73 for
Refrigerant Coil Connections and Circuiting.
Table U-29
Filter Data
| |
Area(Ft2) |
Qty-Size |
| 2,4Flat (TA,
permanent, pleated media) |
13.3 |
6-16x20 |
| Angled (TA, permanent, pleated media) |
16.7 |
6-20x20 |
| Bag/Cartridge(65%, 85% or 95% Efficiency) |
10.0 |
3-20x24 |
Refer to page 78
for filter pressure drops.
Table U-30 Areas
| |
Area(Ft2) |
| Traq Damper Mixing Box, |
| Mixing Box or Economizer Traq Damper |
4.19 |
| Airfoil Blade Damper |
8.26 |
| Internal Face and Bypass |
| Face Area |
6.62 |
| Bypass Area |
2.21 |
| External Face and Bypass |
Face Area |
11.03 |
Bypass Area |
4.41 |
| Face Damper |
11.03 |
| Multizone (per deck) |
4.98 |
| (Max. zones/deck) |
9 |
| Air Blender |
5.14 |
Refer to pages 74-79
for pressure drops. See Table P-14 on page 79 for damper torque
requirements. |