   Trane Company (The)  Series R Rotary Liquid Chillers  

Series R Rotary Liquid Chillers - Page 211

 

 

Model Number Description 

 

Model Nomenclature 

Digit Number 
 

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17

70-125 Tons 

Digits 1,2 — Unit Model 

RT = Rotary Chiller 

Digit 3 — Unit Type 

A = Air Cooled 

Digit 4 — Development Sequence 

A = First Sequence 

Digit 5,6 & 7 — Nominal Capacity 

070 = 70 tons 100 = 100 tons 

080 = 80 tons 110 = ll0 tons 

090 = 90 tons 125 = 125 tons 

Digit 8 — Unit Voltage 

A = 200/60/3 4= 460/60/3 

C = 230/60/3 5= 575/60/3 

J = 346/50/3 S = Special

Digit 9 — Compressor Starter Type

Y = Y-Delta Closed Transition

X = X-Line (Across the Line) 

S = Special 

 

Digit 10,11 — Design Sequence 

AO = First Sequence (Factory Input) 

Digit 12 — Evaporator Leaving Temperature 

1 = Standard 40 to 65 F 

2= Low 0 to 39 F 

3 = Ice-Making 20 to 65 F 

S = Special 

Digit 13 — Condenser Coil Fin Material 

A = Aluminum 

B = Blue Fin™ Coil Protection 

S = Special 

Digit 14 — Agency Listing 

O = No Agency Listing 

1 = UL Listing

2 = C.S.A Listing 

Digit 15 — Control Interface 

C = Deluxe without Communication 

D = Deluxe with Communication 

Digit 16 — Chilled Water Reset 

O = No Chilled Water Reset 

1 = Based on Return Water Temperature 

2 = Based on Outside Air Temperature 

Digit 17 — Miscellaneous Factory Installed Options 

A = Architectural Louvered Panels 

B = Control Power Transformer 

D = Low Ambient Lockout Sensor 

E = Suction Service Valve 

F = Power Disconnect 

G = Low Ambient Operation 

K = Coil Protection 

M = Access Guard 

Field Installed Options 

Q = Spring Isolators 

N = Neoprene Isolators 

R = Remote Display Panel 

3 = 5 Year Compressor Warranty 

8 = Architectural Louvered Panels 

9 = Coil Protection 

O = Access Guard 

130 - 400 Tons

Digits 1,2 — Unit Model 

RT = Rotary Chiller 

Digit 3 — Unit Type 

A = Air Cooled 

Digit 4 — Development Sequence 

A = First Sequence 

Digit 5,6&7– Nominal Capacity 

130 = 130 tons 240 = 240 tons 

140 = 140 tons 270 = 270 tons 

155 = 155 tons 300 = 300 tons 

170 = 170 tons 340 = 340 tons 

185 = 185 tons 370 = 370 tons 

200 = 200 tons 400 = 400 tons 

215 = 215 tons 

Digit 8 – Unit Voltage 

G = 200-230/60/3 Dual Voltage 

J = 346/50/3

K = 380-415/50/3 Dual Voltage 

4 = 460/60/3 

5 = 575/60/3 

S = Special 

Digit 9 — Compressor Starter Type 

Y = Y-Delta Closed Transition 

X = X-Line (Across the Line) 

S = Special 

Digit 10, 11 — Design Sequence 

EO = First Sequence (Factory Input) 

Digit 12 — Evaporator Leaving Temperature 

1 = Standard 40 to 65 F 

2= Low 0 to 39 F 

3 = Ice-Making 20 to 65 F 

S = Special 

Digit 13 — Condenser Coil Fin Material 

A = Aluminum 

B = Blue Fin™ Coil Protection 

S = Special 

Digit 14 — Agency Listing 

O = No Agency Listing 

1 = UL Listing 

2 = CS,A. Listing 

Digit 15 — Control Interface 

C = Deluxe without Communication 

D = Deluxe with Communication 

Digit 16 — Chilled Water Reset 

O = No Chilled Water Reset 

1 = Based on Return Water Temperature 

2 = Based on Outside Air Temperature

Digit 17 — Miscellaneous Factory Installed Options 

A = Architectural Louvered Panels 

B = Control Power Transformer 

C = Domestic Water Heater 

D = Low Ambient Lockout Sensor 

E = Suction Service Valve 

F = Power Disconnect 

G = Low Ambient Operation 

K = Coil Protection 

M = Access Guard 

Field Installed Options 

2 = Remote Display Panel 

5 = 5 Year Compressor Warranty

N = Neoprene Isolators 

6 = Spring Isolators 

7 = Architectural Louvered Panels 

J = Remote EVP 

8 = Coil Protection 

9 = Access Guard

 

Request for Information / Request a Catalog from Trane Company (The)
 
 
 
To request more information from Trane Company (The), please complete the form below.
 
*Name:    
*Email:    
Company:    
*Company type:    
Phone:    
*Address:    
*Request:    
    (* = Mandatory field) 
Please add me to the mailing list for the free monthly e-Newsletter AECnews.  
     






Printable version Bookmark this page Notify a colleague or friend about this pageHome | Terms of Use | Privacy Statement | Link to AECinfo
AECinfo is a member of Docu Group, the world's largest building products information network.



Copyright © 1996–2009 AECinfo.com