Performance Data
Table 34.1 -- Natural Gas Heating Capacities
| Tons |
Module |
(MBh) |
(MBh) |
4000 |
5000 |
5760 |
6000 |
6284 |
7000 |
8000 |
9000 |
9792 |
10000 |
10682 |
10830 |
11200 |
11750 |
12000 |
13500 |
15000 |
| 20 |
Low |
235 |
192.7 |
44 |
36 |
31 |
30 |
28 |
25 |
22 |
20 |
|
|
|
|
|
|
|
|
|
| |
High |
500 |
410.0 |
|
|
66 |
63 |
60 |
54 |
47 |
42 |
|
|
|
|
|
|
|
|
|
| 25 |
Low |
235 |
192.7 |
|
36 |
31 |
30 |
28 |
25 |
22 |
20 |
18 |
18 |
17 |
16 |
|
|
|
|
|
| |
High |
500 |
410.0 |
|
|
66 |
63 |
60 |
54 |
47 |
42 |
39 |
38 |
35 |
35 |
34 |
|
|
|
|
| 30 |
Low |
350 |
287.0 |
|
|
|
44 |
42 |
38 |
33 |
29 |
27 |
26 |
25 |
24 |
24 |
23 |
22 |
20 |
|
| |
High |
500 |
410.0 |
|
|
|
|
60 |
54 |
47 |
42 |
39 |
38 |
35 |
35 |
34 |
32 |
31 |
28 |
|
| 40 |
Low |
350 |
287.0 |
|
|
|
|
|
|
33 |
29 |
27 |
26 |
25 |
24 |
24 |
23 |
22 |
20 |
18 |
| |
High |
850 |
697.0 |
|
|
|
|
|
|
|
|
66 |
64 |
60 |
59 |
57 |
55 |
54 |
48 |
43 |
| 50 |
Low |
500 |
410.0 |
|
|
|
|
|
|
|
|
|
38 |
35 |
35 |
34 |
32 |
31 |
28 |
25 |
| |
High |
850 |
697.0 |
|
|
|
|
|
|
|
|
|
|
60 |
59 |
57 |
55 |
54 |
48 |
43 |
| 55 |
Low |
500 |
410.0 |
|
|
|
|
|
|
|
|
|
38 |
35 |
35 |
34 |
32 |
31 |
28 |
25 |
| |
High |
850 |
697.0 |
|
|
|
|
|
|
|
|
|
|
|
|
|
55 |
54 |
48 |
43 |
| 60 |
Low |
500 |
410.0 |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
31 |
28 |
25 |
| |
High |
850 |
697.0 |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
54 |
48 |
43 |
| 70 |
Low |
500 |
410.0 |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
31 |
28 |
25 |
| |
High |
850 |
697.0 |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
54 |
48 |
43 |
| 75 |
Low |
500 |
410.0 |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
31 |
28 |
25 |
| |
High |
850 |
697.0 |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
54 |
48 |
43 |
| Tons |
Module |
(MBh) |
(MBh) |
16129 |
18000 |
20000 |
22500 |
230040 |
25000 |
27000 |
29377 |
30000 |
| 20 |
Low |
235 |
192.7 |
|
|
|
|
|
|
|
|
|
| |
High |
500 |
410.0 |
|
|
|
|
|
|
|
|
|
| 25 |
Low |
235 |
192.7 |
|
|
|
|
|
|
|
|
|
| |
High |
500 |
410.0 |
|
|
|
|
|
|
|
|
|
| 30 |
Low |
350 |
287.0 |
|
|
|
|
|
|
|
|
|
| |
High |
500 |
410.0 |
|
|
|
|
|
|
|
|
|
| 40 |
Low |
350 |
287.0 |
16 |
|
|
|
|
|
|
|
|
| |
High |
850 |
697.0 |
40 |
36 |
|
|
|
|
|
|
|
| 50 |
Low |
500 |
410.0 |
23 |
21 |
19 |
17 |
|
|
|
|
|
| |
High |
850 |
697.0 |
40 |
36 |
32 |
29 |
|
|
|
|
|
| 55 |
Low |
500 |
410.0 |
23 |
21 |
19 |
17 |
16 |
|
|
|
|
| |
High |
850 |
697.0 |
40 |
36 |
32 |
29 |
28 |
26 |
|
|
|
| 60 |
Low |
500 |
410.0 |
23 |
21 |
19 |
17 |
16 |
15 |
14 |
|
|
| |
High |
850 |
697.0 |
40 |
36 |
32 |
29 |
28 |
26 |
24 |
|
|
| 70 |
Low |
500 |
410.0 |
23 |
21 |
19 |
17 |
16 |
15 |
14 |
13 |
13 |
| |
High |
850 |
697.0 |
40 |
36 |
32 |
29 |
28 |
26 |
24 |
22 |
|
| 75 |
Low |
500 |
410.0 |
23 |
21 |
19 |
17 |
16 |
15 |
14 |
13 |
13 |
| |
High |
850 |
697.0 |
40 |
36 |
32 |
29 |
28 |
26 |
24 |
22 |
|
Note:
1. All heaters are 82% efficient.
2. Cfm values below the minimums and above the maximums
shown in this table are not UL/CSA approved, see RT-EB-104 for further details.
3. Air Temperature Rise = Heat Output (Btu) ÷ (Cfm x
1.085).
Table 34.2 -- Natural Gas Heating Capacities
| Nominal Tons |
Gas Heat Module |
Heat Input (MBh) |
Heat Output (MBh) |
Air
Temperature Rise Vs Unit Cfm CFM |
| 28,350 |
30,250 |
32,550 |
34,750 |
37,000 |
39,250 |
41,500 |
43,000 |
46,000 |
| 90 |
High |
1000 |
820 |
27 |
25 |
23 |
22 |
20 |
19 |
18 |
18 |
|
| 105 |
High |
1000 |
820 |
- |
- |
23 |
22 |
20 |
19 |
18 |
18 |
16 |
| 115 |
High |
1000 |
820 |
- |
- |
23 |
22 |
20 |
19 |
18 |
18 |
16 |
| 130 |
High |
1000 |
820 |
- |
- |
23 |
22 |
20 |
19 |
18 |
18 |
16 |
Note:
1. All heaters are 82% efficient.
2. Cfm values below the minimums and above the maximums
shown in this table are not UL/CSA approved, see RT-EB-104 for further details.
3. Air Temperature Rise = Heat Output (Btu) ÷ (Cfm x
1.085).
Table 34.3 -- Steam Heating Heating Capacities
(Q/ITD)1
20 Nominal Ton Unit
| Steam Module |
Unit
Standard Air Volume (Cfm) |
| 4000 |
6000 |
8000 |
10000 |
10000 |
| Low |
Heat |
0.95 |
1.18 |
1.37 |
1.52 |
| High |
Heat |
1.94 |
2.47 |
2.95 |
3.31 |
30 Nominal Ton Unit
| Steam Module |
Unit Standard Air Volume (Cfm) |
| 6000 |
9000 |
12000 |
15000 |
15000 |
| Low |
Heat |
1.18 |
1.64 |
1.69 |
2.00 |
| High |
Heat |
2.47 |
3.12 |
3.59 |
3.95 |
25 Nominal Ton Unit
| Steam Module |
Unit
Standard Air Volume (Cfm) |
| 5000 |
7500 |
10000 |
12500 |
12500 |
| Low |
Heat |
1.06 |
1.33 |
1.52 |
1.74 |
| High |
Heat |
2.20 |
2.85 |
3.31 |
3.65 |
40 Nominal Ton Unit
| Steam Module |
Unit
Standard Air Volume (Cfm) |
| 8000 |
12000 |
16000 |
20000 |
20000 |
| Low |
Heat |
1.61 |
2.01 |
2.29 |
2.60 |
| High |
Heat |
3.36 |
4.28 |
4.93 |
5.43 |
55 Nominal Ton Unit
| Steam Module |
Unit
Standard Air Volume (Cfm |
| 11000 |
16500 |
22000 |
27500 |
27500 |
| Low |
Heat |
1.91 |
2.38 |
2.72 |
2.92 |
| High |
Heat |
4.09 |
5.01 |
5.64 |
6.41 |
50 Nominal Ton Unit
| Steam Module |
Unit
Standard Air Volume (Cfm) |
| 10000 |
15000 |
20000 |
25000 |
25000 |
| Low |
Heat |
1.82 |
2.21 |
2.60 |
2.85 |
| High |
Heat |
3.86 |
4.79 |
5.43 |
5.97 |
60 Nominal Ton Unit
| Steam Module |
Unit
Standard Air Volume (Cfm) |
| 12000 |
18000 |
24000 |
30000 |
30000 |
| Low |
Heat |
2.32 |
2.81 |
3.33 |
3.71 |
| High |
Heat |
3.85 |
4.84 |
5.62 |
6.18 |
90, 105, 115, 130 Nominal Ton Unit
| Steam Module |
Unit
Standard Air Volume (Cfm) |
| 27000 |
33000 |
40000 |
46000 |
46000 |
| Low |
Heat |
5.17 |
5.70 |
6.19 |
6.53 |
| High |
Heat |
8.83 |
8.80 |
9.04 |
9.26 |
70 & 75 Nominal Ton Unit
| Steam Module |
Unit
Standard Air Volume (Cfm) |
| 16000 |
20000 |
24000 |
30000 |
30000 |
| Low |
Heat |
2.65 |
2.98 |
3.33 |
3.71 |
| High |
Heat |
4.50 |
5.10 |
5.62 |
6.18 |
Note:
1. Capacities expressed as MBH (Q) per initial temperature
difference (ITD) between the entering air temperature to the steam module and the entering
steam temperature. Maximum recommended operating pressure is 35 PSIG.
Table 34.4 -- Properties of Steam
| Steam Pressure (Psig) |
2 |
5 |
10 |
15 |
20 |
25 |
30 |
40 |
50 |
| Temperature Of Steam (F) |
219 |
227 |
239 |
250 |
259 |
267 |
274 |
287 |
298 |
|