Performance Data 30 Ton
Table 40-1
Supply Fan Performance WITH INLET VANES 30 Ton
Cfm Std Air |
Total Static Pressure |
.250 |
.500 |
,750 |
1.000 |
1.250 |
1.500 |
1.750 |
2.000 |
RPM |
BHP |
RPM |
BHP |
RPM |
BHP |
RPM |
BHP |
RPM |
BHP |
RPM |
BHP |
RPM |
BHP |
RPM |
BHP |
| 6000 |
327 |
.53 |
433 |
.93 |
526 |
1.34 |
607 |
1.83 |
677 |
2.43 |
739 |
3.08 |
794 |
3.73 |
844 |
4.37 |
| 7000 |
349 |
.70 |
440 |
1.10 |
529 |
1.61 |
608 |
2.09 |
679 |
2.62 |
743 |
3.28 |
801 |
4.00 |
853 |
4.76 |
| 8000 |
376 |
.94 |
453 |
1.34 |
534 |
1.85 |
611 |
2.45 |
680 |
3.00 |
744 |
3.57 |
803 |
4.24 |
857 |
5.02 |
| 9000 |
406 |
1.25 |
472 |
1.64 |
543 |
2.15 |
615 |
2.77 |
683 |
3.45 |
746 |
4.06 |
804 |
4.68 |
858 |
5.36 |
| 10000 |
438 |
1.63 |
496 |
2.02 |
559 |
2.54 |
623 |
3.13 |
687 |
3.85 |
749 |
4.60 |
806 |
5.30 |
860 |
5.97 |
| 11000 |
471 |
2.09 |
523 |
2.49 |
578 |
3.00 |
636 |
3.60 |
695 |
4.29 |
753 |
5.08 |
809 |
5.91 |
863 |
6.70 |
| 12000 |
505 |
2.62 |
552 |
3.05 |
601 |
3.56 |
653 |
4.17 |
707 |
4.84 |
760 |
5.60 |
814 |
6.46 |
866 |
7.37 |
| 13000 |
538 |
3.24 |
583 |
3.72 |
627 |
4.22 |
674 |
4.82 |
723 |
5.51 |
772 |
6.26 |
822 |
7.09 |
871 |
8.01 |
| 13500 |
555 |
3.59 |
599 |
4.08 |
641 |
4.59 |
685 |
5.19 |
732 |
5.89 |
779 |
6.64 |
827 |
7.45 |
875 |
8.35 |
Cfm Std Air |
Total Static Pressure |
2.250 |
2.500 |
2.750 |
3.000 |
3.250 |
3.500 |
3.750 |
4.000 |
RPM |
BHP |
RPM |
BHP |
RPM |
BHP |
RPM |
BHP |
RPM |
BHP |
RPM |
BHP |
RPM |
BHP |
RPM |
BHP |
| 6000 |
890 |
5.01 |
933 |
5.66 |
974 |
6.32 |
1012 |
6.99 |
1049 |
7.67 |
1084 |
8.36 |
1118 |
9.08 |
1151 |
9.80 |
| 7000 |
902 |
5.52 |
947 |
6.27 |
989 |
7.02 |
1029 |
7.77 |
1066 |
8.52 |
1102 |
9.28 |
1137 |
10.05 |
1170 |
10.83 |
| 8000 |
908 |
5.85 |
955 |
6.71 |
999 |
7.58 |
1041 |
8.45 |
1080 |
9.30 |
1117 |
10.16 |
1152 |
11.01 |
1186 |
11.87 |
| 9000 |
910 |
6.15 |
959 |
7.03 |
1004 |
7.96 |
1048 |
8.92 |
1088 |
9.89 |
1127 |
10.87 |
1164 |
11.84 |
1199 |
12.81 |
| 10000 |
911 |
6.68 |
960 |
7.46 |
1006 |
8.34 |
1050 |
9.30 |
1092 |
10.31 |
1133 |
11.36 |
1171 |
12.43 |
1208 |
13.52 |
| 11000 |
913 |
7.44 |
961 |
8.19 |
1007 |
8.97 |
1051 |
9.83 |
1094 |
10.78 |
1135 |
11.81 |
1174 |
12.90 |
1212 |
14.03 |
| 12000 |
916 |
8.26 |
964 |
9.09 |
1009 |
9.90 |
1053 |
10.71 |
1095 |
11.57 |
1136 |
12.49 |
1175 |
13.50 |
1213 |
14.58 |
| 13000 |
920 |
8.98 |
967 |
9.96 |
1012 |
10.90 |
1055 |
11.79 |
1097 |
12.66 |
1137 |
13.54 |
1176 |
14.46 |
1214 |
15.44 |
| 13500 |
922 |
9.34 |
969 |
10.36 |
1014 |
11.37 |
1057 |
12.33 |
1098 |
13.25 |
1138 |
14.16 |
1177 |
15.07 |
1215 |
16.02 |
Cfm Std Air |
Total Static Pressure |
4.250 |
4.500 |
4.750 |
5.000 |
5.250 |
5.500 |
5.750 |
6.000 |
RPM |
BHP |
RPM |
BHP |
RPM |
BHP |
RPM |
BHP |
RPM |
BHP |
RPM |
BHP |
RPM |
BHP |
RPM |
BHP |
| 6000 |
1183 |
10.54 |
1213 |
11.30 |
1243 |
12.07 |
1272 |
12.86 |
1300 |
13.66 |
1328 |
14.47 |
1355 |
15.30 |
|
|
| 7000 |
1202 |
11.62 |
1233 |
12.42 |
1263 |
13.23 |
1293 |
14.06 |
1321 |
14.90 |
1349 |
15.75 |
1376 |
16.62 |
|
|
| 8000 |
1219 |
12.73 |
1251 |
13.60 |
1282 |
14.47 |
1311 |
15.36 |
1340 |
16.25 |
1368 |
17.15 |
|
|
|
|
| 9000 |
1233 |
13.77 |
1266 |
14.73 |
1297 |
15.69 |
1327 |
16.66 |
1357 |
17.62 |
|
|
|
|
|
|
| 10000 |
1243 |
14.60 |
1276 |
15.68 |
1309 |
16.76 |
1340 |
17.83 |
1370 |
18.90 |
|
|
|
|
|
|
| 11000 |
1248 |
15.19 |
1283 |
16.37 |
1317 |
17.56 |
1349 |
18.75 |
|
|
|
|
|
|
|
|
| 12000 |
1250 |
15.73 |
1286 |
16.93 |
1321 |
18.16 |
1354 |
19.42 |
|
|
|
|
|
|
|
|
| 13000 |
1251 |
16.49 |
1287 |
17.61 |
1322 |
18.81 |
1356 |
20.06 |
|
|
|
|
|
|
|
|
| 13500 |
1252 |
17.02 |
1288 |
18.09 |
1323 |
19.23 |
1357 |
20.45 |
|
|
|
|
|
|
|
|
Notes:
1. Shaded areas at table extremes note non-standard Bhp or
Rpm selection. Contact your local Trane representative for more information.
2. Supply fan performance table includes internal
resistance of rooftop. For total static pressure determination, system external static
must be added to appropriate component static pressure
drops (evaporator coil, filters, optional economizer,
optional exhaust fan, optional heating system, optional cooling only extended casing,
optional roof curb).
3. Minimum motor horsepower is 5 hp, maximum motor
horsepower is 20 hp. Maximum RPM is 1379.
4. See RT-EB-104 for further details.

Important: Maximum static pressure leaving the
roof top is 4.0" H2O positive.The static pressure drops from the supply
fan to the space cannot exceed 4.0" H2O. |