Options |
A full range of factory-installed modular options are available on standard ship cycles, allowing your rooftop design to be
best suited to each individual application.
Cooling Only/Heating Casings
- Cooling Only Two casing choices are available, one designed for high airside efficiency and one for sound sensitive
applications. The 90 through 130 ton are extended
casing only.
- Electric Heat Nickel-chromium electric heating elements in individually fused circuits of 48 amps or less and with all
necessary safeties. A full range of sizing options is
available.
- Natural Gas Heat -- Two Stage and Limited Modulation Two-pass stainless
steel tubular free floating heat exchanger has
industrial type burner and combustion blower. Available
with high or low fire and UL or CSA approval.
- Natural Gas Heat - Full Modulation The heat exchanger drum, tubes and front and rear headers are constructed of the
most corrosion resistant austenitic stainless steel
alloys available.
- Steam Heat ARI certified type NS coil with non-freeze steam distribution. Coils are pitched for drainage and are provided
with steam modulating valve with actuator. High and low
heat options are available.
- Hot Water Heat ARI certified type W coil mounted for drainage and provided with hot water modulating valve with actuator.
High and low heat options are available.
Power Supplies
Rooftops are available with 200, 230, 460 and 575 voltage power supplies.
Exhaust
- No Exhaust Rooftops can be built for makeup air applications with no exhaust. Relief opening is sealed watertight.
- Barometric Relief Gravity dampers are provided that open to relieve positive
pressure.
- 50 Percent Exhaust Fan One double inlet forward-curved fan can exhaust up to 50 percent of supply air. Control is on/off
based on economizer damper position. Barometric dampers
at fan outlet prevent air backdraft.
- 100 Percent Modulating Exhaust Fan Two double inlet forward-curved fans can
exhaust up to 100 percent supply air. Fans operate when
economizer damper is open greater than minimum position. Discharge dampers at fan outlet modulate in response toeconomizer damper position on CV rooftops.
- 100 Percent Modulating Exhaust with Statitrac Control For both CV and VAV rooftops, the 100 percent modulating
exhaust discharge dampers are modulated in response to
building pressure. A differential pressure control system, called Statitrac,
uses a differential pressure transducer to compare
indoor building pressure to atmospheric pressure. The
FC exhaust fan is turned on when required to lower building static pressure to
setpoint. The Statitrac control system then modulates
the discharge dampers to control the building pressure to within the adjustable,
specified dead band that is set at the Human Interface
Panel.
Filters
- No Filters (two inch throwaway filter rack only) complete set of two-inch thick filter racks, without the filter media
to accommodate applications which require field
supplied filters.
- No Filters (bag/cartridge with prefilter filter rack) long-lasting galvanized steel frame without the filter media to accommodate applications which require
field supplied filters.
- Throwaway Two-inch, 30 percent efficient throwaway filters, includes rack as standard.
- Cleanable Wire Mesh Two-inch permanent washable wire mesh filters are provided with metal frame.
- High-Efficiency Throwaway Two inch throwaway filters include rack and have an average arrestance in excess of 90 percent
when tested in accordance with ASHRAE 52-76.
- 90-95 Percent Bag Filter (with prefilter) Glass fiber extended media bag filter is mounted in a galvanized steel frame. 90-95 percent dust spot efficiency. Two-inch throwaway
prefilters are included with this option.
- 90-95 Percent Cartridge Filter (with prefilter) These twelve-inch deep cartridge filters are mounted in a galvanized
steel frame. They are Class 1 listed by Underwriters
Laboratories and have a 90-95 percent dust spot efficiency per ASHRAE 52-76. To ensure
maximum cartridge filter life, two-inch prefilters are
included.
Fresh Air
- 0 Through 25 Percent Manual Outside Air Includes outside air opening with moisture eliminator and manually positioned
damper for drawing up to 25 percent outside air. (20-75
tons only)
- Economizer Includes the primary temperature controls necessary to automatically
use outdoor air for free cooling. Option includes
modulating return and outside air dampers, enthalpy lockout, minimum position control and spring return motor. It is provided
with standard low leak outside air dampers with a
leakage rate of 2.5 percent of nominal airflow at one
inch W.C. static pressure.
System Control
- Constant Volume Provided with all the necessary controls to operate rooftop
from a zone sensor, including CV microprocessor unit
control module, a microprocessor compressor controller and a unit mounted Human Interface Panel.
- VAV Supply Air Temperature control without inlet guide vanes Provided with
all the necessary controls to operate a VAV rooftop
from the discharge air temperature, including discharge air microprocessor controller and discharge air sensor. The microprocessor
controller coordinates the economizer control and the
stages of cooling with zone or outdoor air reset
capabilities and an adjustable control band to fine-tune the control to specific
applications.
- VAV Supply Air Temperature control with inlet guide vanes Provided with all
the necessary controls to control/ operate a VAV
rooftop from the discharge air temperature, including a
discharge air microprocessor controller, a discharge air sensor, pressure sensor and inlet guide vanes. The microprocessor
controller coordinates the economizer control and the
stages of cooling with zone or outdoor air reset
capabilities and an adjustable control band to fine-tune the control to specific applications. The inlet guide vanes are used
with VAV rooftops to control duct static pressure.
Option includes vanes and static pressure controls.
Forward-curved fans with inlet vanes are the most efficient way to mechanically modulate airflow.
- Exhaust Fan Variable Frequency Drives w/o Bypass (with Statitrac Only) Provided with all the necessary controls to
control/maintain building space pressure through a CV
or VAV rooftop. The Variable Frequency Drive (VFD) modulates the speed of the exhaust
fan motor in response to building pressure. A
differential
|