Model Number Description |
Following is a complete description of the fan-coil model
number. Each digit in the model number has a corresponding code that identifies the
specific option.
FC B B 020
1 C JO A 0 G
1 0 A A 2 M
000 0 0 1 0 0
0 A A 000 000 0
0 0 0 A 0 0
1
5
10
15
20
25
30
35
40
44
Digit 1, 2 - Unit Type
FC = Fan-Coil
Digit 3 - Cabinet Type
A = Vertical Concealed
B = Vertical Cabinet
C = Horizontal Concealed
D = Horizontal Cabinet
E = Horizontal Recessed
H = Vertical Recessed
J = Vertical Cabinet Slope Top
K = Low Vertical Concealed
L = Low Vertical Cabinet
Digit 4 - Development Sequence 'B'
Digit 5, 6, 7 - Unit Size
020 040 080
030 060 100
120
Digit 8 - Unit Voltage
| 1 = 1 1 5/60/1 |
8 = 110-120/50/1 |
| 2 = 208/60/1 |
9 = 220-240/50/1 |
| 3 = 277/60/1 |
|
| 4 = 230/60/1 |
|
Digit 9 - Piping System/Placement
A = No piping, RH, No Auxiliary Drain Pan
B = No piping, LH, No Auxiliary Drain Pan
C = No piping, RH, with Auxiliary Drain Pan
D = No piping, LH, with Auxiliary Drain Pan
E = No piping, RH, No Auxiliary Drain Pan, Extended End
Pocket
F= No piping, LH, No Auxiliary Drain Pan, Extended End
Pocket
G = No piping, RH, with Auxiliary Drain Pan, Extended
End Pocket
H = No piping, LH, with Auxiliary Drain Pan, Extended
End Pocket
J = With piping package, RH
K = With piping package, LH
L = With piping package, RH, Extended End Pocket
M = With piping package, LH, Extended End Pocket
Digit 10, 11 - Design Sequence "JO"
Digit 12 - Inlets
A = Front Toe Space
B = Front Bar Grille
C = Front Stamped Louver
D = Bottom Stamped Louver
E = Bottom Toe Space
F = Back Duct Collar
G = Back Open Return
H = Back Stamped Louver
Digit 13 - Fresh Air Damper
0 = None
A = Manual, Bottom Opening
B = Manual, Back Opening
C = Manual, Top Opening
D = Auto, 2-Position, Bottom Opening
E = Auto, 2-Position, Back Opening
F = Auto, 2-Position, Top Opening
G = Auto, Economizer, Bottom Opening*
H = Auto, Economizer, Back Opening*
J = Auto, Economizer, Top Opening*
K = No Damper, Bottom Opening
L = No Damper, Back Opening
M = No Damper, Bottom Opening
Digit 14 - Outlets
A = Front Duct Collar
B = Front Bar Grille
C = Front Stamped Louver
D = Front Quad Grille
G = Top Quad Grille
H = Top Bar Grille
J = Top Duct Collar
Digit 15 - Color
0 = No Paint (Concealed Units Only)
1 = Deluxe Beige 4 = Driftwood Grey
2 = Soft Dove 5 = Stone Grey
3 = Cameo White 6 = Rose Mauve
Digit 16 - Tamperproof Locks/Leveling Feet
0 = None
B = Keylock Access Door
C = Keylock Panel and Access Door
D = Leveling Feet
F = Keylock Access Door with Leveling Feet
G = Keylock Panel and Access Door with Leveling Feet
Digit 17 - Motor
A = Free Discharge
B = High Static
Digit 18 - Coil
A = 2 Row Cooling/Heating
B = 3 Row Cooling/Heating
C = 4 Row Cooling/Heating
D = 2 Row Cooling/l Row Heating
E = 2 Row Cooling/2 Row Heating
F = 3 Row Cooling/l Row Heating
G = 2 Row Cooling Only
H = 3 Row Cooling Only
J = 4 Row Cooling Only
K = 2 Row Cooling/Heating with Electric Heat
L = 3 Row Cooling/Heating with Electric Heat
M = 4 Row Cooling/Heating with Electric Heat
P = 2 Row Cooling/Heating with 1 Row Heating
Q = 2 Row Cooling/Heating with 2 Row Heating
R = 3 Row Cooling/Heating with 1 Row Heating
Digit 19 - Coil Series
2 = 144 FPF
Digit 20 - Coil Air Vent
A = Automatic Air Vent
M = Manual Air Vent
Digit 21, 22, 23 - Electric Heat kW - ( ) = 208V
Derate
000 = No Electric Heat
010 = 1.0 kW (0.75 kW)
015 = 1.5 kW (1.1 kW)
020 = 2.0 kW (1.5 kW)
025 = 2.5 kW (1.9 kW)
030 = 3.0 kW (2.3 kW)
040 = 4.0 kW (3.0 kW)
050 = 5.0 kW (3.8 kW)
060 = 6.0 kW (4.5 kW)
070 = 7.0 kW (5.3 kW)
08 O= 8.0 kW (6.0 kW)
100 = 10.0 kW
Digit 24 - Reheat Coil
0 = None
B
= Hot Water Coil
A = Steam Coil
Digit 25 - Disconnect Switch
0 = None
D = Disconnect Switch
* = Available with TUC controls only |