| Model Number Description Digit 26 Filter 0 = None 1 = 1" Throwaway Filter 2 = 1" Throwaway Pleated Media Filter 3 = 1" Throwaway + (1) Extra 4 = 1" Throwaway Pleated Media + (1) Extra 5 = 1" Throwaway + (2) Extras 6 = 1" Throwaway Pleated Media + (2) Extras 7 = 1" Throwaway + (3) Extras 8 = 1" Throwaway Pleated Media + (3) Extras Digit 27 Main Control Valve 0 = None A = 2-Way, 2-Position, NO (25 psig) B = 3-Way, 2-Position, NO (30 psig) C = 3-Way, 2-Position, NC (15 psig) E = 2-Way, 2-Position, NO (50 psig) F = 3-Way, 2-Position, NO (50 psig) G = 2-Way, 2-Position, NC (50 psig) H = 3-Way, 2-Position, NC (50 psig) J = 2-Way, Modulating, 0.7 Cv (50 psig)* K = 3-Way, Modulating, 0.7 Cv (50 psig)* L = 2-Way, Modulating, 1.5 Cv (50 psig)* M= 3-Way, Modulating, 1.5 Cv (50 psig)* N = 2-Way, Modulating, 2.5 Cv (50 psig)* P = 3-Way, Modulating, 2.5 Cv (50 psig)* Q = 2-Way, Modulating, 4.0 Cv (40 psig)* R = 3-Way, Modulating, 4.0 Cv (40 psig)* X = Field-supplied, NO Y = Field-supplied, NC Digit 28 Auxiliary Control Valve 0 = None A = 2-Way, 2-Position, NO (25 psig) B = 2-Way, 2-Position, NC (25 psig) D = 3-Way, 2-Position, NC (15 psig) E = 2-Way, 2-Position, NO (50 psig) F = 3-Way, 2-Position, NO (50 psig) G = 2-Way, 2-Position, NC (50 psig) H = 3-Way, 2-Position, NC (50 psig) J = 2-Way, Modulating, 0.7 Cv (50 psig)* K = 3-Way, Modulating, 0.7 Cv (50 psig)* L = 2-Way, Modulating, 1.5 Cv (50 psig)* M= 3-Way, Modulating, 1.5 Cv (50 psig)* N = 2-Way, Modulating, 2.5 Cv (50 psig)* P = 3-Way, Modulating, 2.5 Cv (50 psig)* Q = 2-Way, Modulating, 4.0 Cv (40 psig)* R = 3-Way, Modulating, 4.0 Cv (40 psig)* X = Field-suppled, NO Y = Field-suppled, NC Digit 29 Piping Packages 0 = None A = Basic Ball Valve Supply and Return B = Basic Ball Valve Supply/Manual Circuit Setter C = Basic Ball Valve Supply and Return with Auto Circuit Setter D = Deluxe Ball Valve Supply and Return E = Deluxe Ball Valve Supply/Manual Circuit Setter F = Deluxe Ball Valve Supply and Return with Auto Circuit Setter Digit 30 Control Type A = Fan Mode Switch C = TUC D = TUC with Trane ICS E = Thermostat Module Digit 31 Control Option D, K = Fan Mode Switch V- X = Thermostat Module and TUC Zone Sensor Options (See Controls Section of catalog for detailed descriptions) Digit 32, 33, 34 Future Control Functions Digit 35 Control Function #3 0 = None 2 = Condensate Overflow Detection Digit 36 Control Function #4 0 = None 2 = Low Temperature Detection Digit 37, 38 Future Control Functions Digit 39 Projection Panels and Falsebacks 0 = None A= 5 /8 " Standard Recessed Panel (Vertical Recessed Units Only) B = 2" Projection Panel C = 2.5" Projection Panel D= 3" Projection Panel L = 2"Falseback E = 3.5" Projection Panel M= 3" Falseback F = 4" Projection Panel N = 4" Falseback G= 4.5" Projection Panel P = 5" Falseback H= 5" Projection Panel Q = 6" Falseback J = 5.5" Projection Panel R = 7" Falseback K = 6" Projection Panel T = 8" Falseback Digit 40 Main Autoflow GPM A = 0.5 G = 3.0 N = 7.0 B = 0.75 H = 3.5 P = 8.0 C = 1.0 J = 4.0 Q = 9.0 D = 1.5 K = 4.5 R = 10.0 E = 2.0 L = 5.0 T = 11.0 F = 2.5 M= 6.0 U = 12.0 Digit 41 Auxiliary Autoflow GPM A = 0.5 B = 0.75 C = 1.0 D = 1.5 E = 2.0 F = 2.5 G = 3.0 H = 3.5 J = 4.0 K = 4.5 L = 5.0 M= 6.0 N = 7.0 P = 8.0 Digit 42 Subbases 0 = None A = 2" Subbase B = 3" Subbase C = 4" Subbase D = 5" Subbase E = 6" Subbase F = 7" Subbase Digit 43 Recessed Flange 0 = None A = Recessed Flange Digit 44 Wall Boxes 0 = None A = Anodized Wall Box * = Available with TUC controls only. Note: Please contact your local Trane sales representative for buildable digit combinations. |