Trane Company (The)
Single & Dual Duct VAV Terminal Units
Single & Dual Duct VAV Terminal Units - Page 7
Single & Dual Duct VAV Terminal Units
The features of single and dual duct VAV terminal units are now described by categories. Options for each category are described by codes. This method of describing units replaces the positional digit model number used in the past.
VVCE Cooling Only
VVWE Hot Water Heat
VCEE Electric Heat Categories with their respective codes are now listed below each model type. MODL UNIT MODEL VCCE VariTrane Single Duct Cooling Only Development Sequence E VCWE VariTrane Single Duct Hot Water Heat Development Sequence E VCEE VariTrane Single Duct Electric Heat Development Sequence E DSEQ DESIGN SEQUENCE VALV AIR VALVE SIZE (L/s, mm) 03 300 CFM (5" Inlet) (142, 127) 06 600 CFM (6" Inlet) (283, 152) 11 1100 CFM (8" Inlet) (519, 203) 17 1700 CFM (10" Inlet) (802, 254) 24 2400 CFM (12" Inlet) (1 133, 305) 32 3200 CFM (14" Inlet) (1510, 356) 42 4200 CFM (16" Inlet) (1982, 406) INSL UNIT INSULATION MT.5 1/2" Matt Faced (13 mm) MT1 1" Matt Faced (25 mm) FF.5 1/2" Foil Faced (13 mm) FF1 1" Foil Faced (25 mm) DW.5 Double wall w/1/2" Matt Faced (13 mm) DW1 Double wall w/1" Matt Faced (25 mm) OUTL OUTLET CONNECTION FL Straight Flange VCCE, VCWE Flanged VCEE SD Slip and Drive X Rectangular Frame A-J Integral Outlet SIZE OUTLET SIZE 5WO 5" W/O Damper(127 mm) 5W 5" W/Damper(127 mm) 6WO 6" W/O Damper(152 mm) 6W 6" W/Damper (152 mm) 8WO 8" W/O Damper (203 mm) 8W 8" W/Damper (203 mm) 10WO 10" W/O Damper (254 mm) 10W 10" W/Damper (254 mm) 12W0 12" W/O Damper (305 mm) 14W0 14" W/O Damper (356 mm) CTRL UNIT CONTROL PN = Pneumatic Normally Open PC = Pneumatic Normally Closed ED = Electronic Pressure Dependent El = Electronic Pressure Independent DD = Direct Digital Control UCM PNO1 Normally Open Valve Actuator Only (R.A. T-Stat) PN04 Normally Open Valve Actuator-Trane 3025 Volume Regulator (D.A. T-Stat) PN05 Normally Open Valve Actuator-Trane 3025 Volume Regulator (R.A. T-Stat) PN06 Normally Open Valve Actuator-Trane 2017 Volume Regulator (D.A. T-Stat) PN07 Normally Open Valve Actuator-Trane 2017 Volume Regulator, Reversing Relay (R.A. T-Stat) PN30 Normally Open Valve Actuator-Trane 3025 Volume Regulator Constant Volume PN31 Normally Open Valve Actuator-Trane 2017 Volume Regulator Constant Volume PN32 Normally Open Valve Actuator-Trane 3025 Volume Regulator, N.O. H.W. Valve, Constant Volume (D.A.T.-STAT) PN33 Normally Open Valve Actuator-Trane 2017 Volume Regulator, N.O. H.W. Valve, Constant Volume (D.A.T.-STAT) PN34 Normally Open Valve Actuator-Trane 3025 Volume Regulator Constant Volume (R.A.- T-STAT) PN35 Normally Open Valve Actuator-Trane 2017 Volume Regulator Constant Volume (R.A.- T-STAT) PC01 Normally Closed Valve Actuator Only (D.A. T-Stat) PC02 Normally Closed Valve Actuator Trane 3025 Volume Regulator (D.A. T-Stat) *Note: SI units are rough dimensions. |