| Performance Data |
|
Static Pressure Requirments |
Table P-1 - Models VCCE, VCWE, VDDE (inches W.G.)
| Unit Size |
| Outlet |
Dia |
03 |
06 |
1.1 |
17 |
24 |
| Conn. |
In. |
150 |
225 |
300 |
300 |
450 |
600 |
550 |
825 |
1100 |
850 |
1275 |
1700 |
1200 |
1800 |
2400 |
| A,B,C |
5" |
0.15 |
0.31 |
0.51 |
|
|
|
|
|
|
|
|
|
|
|
|
| 6" |
0.08 |
0.17 |
0.28 |
0.28 |
0.54 |
1.62 |
|
|
|
|
|
|
|
|
|
| 8" |
0.02 |
0.04 |
0.07 |
0.07 |
0.17 |
0.30 |
0.27 |
0.69 |
1.20 |
Note 3 |
|
|
|
| 10" |
|
|
|
|
|
|
0.09 |
0.25 |
0.46 |
0.37 |
0.86 |
1.58 |
Note 3 |
| 12" |
|
|
|
|
|
|
|
|
|
0.16 |
0.33 |
0.59 |
0.24 |
0.65 |
1.18 |
| 14" |
|
|
|
|
|
|
|
|
|
|
|
|
0.140 |
.340 |
.63 |
| D,E,F |
5" |
0.05 |
0.11 |
0.20 |
0.20 |
0.45 |
0.78 |
|
|
|
|
|
|
|
|
|
| 6" |
0.03 |
0.06 |
0.09 |
0.09 |
0.23 |
0.39 |
0.26 |
0.66 |
1.12 |
|
|
|
|
|
|
| 8" |
0.01 |
0.02 |
0.04 |
0.04 |
0.10 |
0.17 |
0.10 |
0.29 |
0.50 |
0.27 |
0.57 |
0.96 |
|
|
|
| 10" |
|
|
|
|
|
|
0.05 |
0.16 |
0.29 |
0.15 |
0.31 |
0.47 |
0.21 |
0.460 |
.82 |
| G |
6" |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| 8" |
|
|
|
|
|
|
|
|
|
0.13 |
0.30 |
0.53 |
|
|
|
| 10" |
|
|
|
|
|
|
|
|
|
|
|
|
0.12 |
0.29 |
0.52 |
| H |
5" |
0.02 |
0.05 |
0.09 |
0.09 |
0.21 |
0.36 |
0.23 |
0.59 |
1.03 |
|
|
|
|
|
|
| 6" |
0.01 |
0.03 |
0.04 |
0.04 |
0.12 |
0.19 |
0.14 |
0.35 |
0.62 |
0.31 |
0.67 |
1.13 |
|
|
|
| 8" |
|
|
|
0.01 |
0.05 |
0.08 |
0.05 |
0.14 |
0.25 |
0.13 |
0.29 |
0.52 |
0.15 |
0.34 |
0.60 |
| 10" |
|
|
|
|
|
|
|
|
|
0.06 |
0.15 |
0.27 |
0.09 |
0.21 |
0.38 |
| 5" |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| J |
6" |
|
|
|
|
|
|
|
|
|
0.19 |
0.40 |
0.75 |
|
|
|
| 8" |
|
|
|
|
|
|
|
|
|
0.09 |
0.21 |
0.35 |
0.08 |
0.19 |
0.35 |
| 10" |
|
|
|
|
|
|
|
|
|
|
|
|
0.05 |
0.11 |
0.20 |
Notes:
1. Add static pressure requirements for
integral outlets to Outlet Connection Code FL or SD pressure drop from appropriate chart
on previous pages.
2. Size 32 and 42 not available with
integral outlets on VDDE only. Size 24 not available with integral outlets.
3. Outlet Connection Code B, Model VCCE
ONLY.
Table P-3 - Models VCCE, VCWE, VDDE
(Metric) (Pascals)
| Unit Size |
| Outlet |
Dia |
03 |
06 |
1 1 |
17 |
24 |
| Conn |
. mm |
71 |
106 |
142 |
142 |
212 |
283 |
260 |
389 |
519 |
401 |
602 |
802 |
566 |
850 |
1133 |
| A,B,C |
127 |
37.35 |
77.19 |
126.99 |
|
|
|
|
|
|
|
|
|
|
|
|
| |
152 |
19.92 |
42.33 |
69.72 |
69.72 |
134.46 |
403.38 |
|
|
|
|
|
|
|
|
|
| |
203 |
4.98 |
9.96 |
17.43 |
17.43 |
42.33 |
74.70 |
67.23 |
171.81 |
298.80 |
Note 3 |
|
|
|
| |
254 |
|
|
|
|
|
|
22.41 |
62.25 |
114.54 |
92.13 |
214.14 |
393.42 |
Note 3 |
| |
305 |
|
|
|
|
|
|
|
|
|
39.84 |
82.17 |
146.91 |
59.76 |
161.85 |
293.82 |
| |
356 |
|
|
|
|
|
|
|
|
|
|
|
|
34.86 |
84.66 |
156.87 |
| D,E,F |
127 |
12.45 |
27.39 |
49.80 |
49.80 |
112.05 |
194.22 |
|
|
|
|
|
|
|
|
|
| |
152 |
7.47 |
14.94 |
22.41 |
22.41 |
57.27 |
97.11 |
64.74 |
164.34 |
278.88 |
|
|
|
|
|
|
| |
203 |
2.49 |
4.98 |
9.96 |
9.96 |
24.90 |
42.33 |
24.90 |
72.21 |
124.50 |
67.23 |
141.93 |
239.04 |
|
|
|
| |
254 |
|
|
|
|
|
|
12.45 |
39.84 |
72.21 |
37.35 |
77.19 |
117.03 |
52.29 |
114.54 |
204.18 |
| G |
152 |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |
203 |
|
|
|
|
|
|
|
|
|
32.37 |
74.70 |
131.97 |
|
|
|
| |
254 |
|
|
|
|
|
|
|
|
|
|
|
|
29.88 |
72.21 |
129.48 |
| H |
127 |
4.98 |
12.45 |
22.41 |
22.41 |
52.29 |
89.64 |
57.27 |
146.91 |
256.47 |
|
|
|
|
|
|
| |
152 |
2.49 |
7.47 |
9.96 |
9.96 |
29.88 |
47.31 |
34.86 |
87.15 |
154.38 |
77.19 |
166.83 |
281.37 |
|
|
|
| |
203 |
|
|
|
2.49 |
12.45 |
19.92 |
12.45 |
34.86 |
62.25 |
32.37 |
72.21 |
129.48 |
37.35 |
84.66 |
149.40 |
| |
254 |
|
|
|
|
|
|
|
|
|
14.94 |
37.35 |
67.23 |
22.41 |
52.29 |
94.62 |
| |
127 |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| J |
152 |
|
|
|
|
|
|
|
|
|
47.31 |
99.60 |
186.751 |
|
|
|
| |
203 |
|
|
|
|
|
|
|
|
|
22.41 |
52.29 |
87.151 |
19.92 |
47.31 |
87.15 |
| |
254 |
|
|
|
|
|
|
|
|
|
|
|
|
12.45 |
27.39 |
49.80 |
Notes:
1. Add static pressure requirements for
integral outlets to Outlet Connection Code FL or SD pressure drop from appropriate chart
on previous pages.
2. Size 32 and 42 not available with
integral outlets on VDDE only. Size 24 not available with integral outlets.
3. Outlet Connection Code B, Model VCCE
ONLY.
| Table P-2 -
Attenuator |
| Unit Size |
CFM Inches W |
G |
| 03 |
150 |
004 |
| 225 |
007 |
| 300 |
010 |
| 06 |
300 |
010 |
| 450 |
021 |
| 600 |
033 |
| 11 |
550 |
007 |
| 825 |
016 |
| 1100 |
028 |
| 17 |
850 |
003 |
| 1275 |
007 |
| 1700 |
013 |
| 24 |
1200 |
003 |
| 1800 |
008 |
| 2400 |
013 |
| 32 |
1600 |
006 |
| 2400 |
010 |
| 3200 |
013 |
| 42 |
2100 |
007 |
| 3150 |
012 |
| 4200 |
017 |
Table P-4 Attenuator (Metric)
| Unit Size |
L/s |
Pa |
| |
71 |
0.996 |
| 03 |
106 |
1.743 |
| |
142 |
2.490 |
| |
142 |
2.490 |
| 06 |
212 |
5.229 |
| |
283 |
8.217 |
| |
260 |
1.743 |
| 11 |
389 |
3.984 |
| |
519 |
6.972 |
| |
401 |
0.747 |
| 17 |
602 |
1.743 |
| |
802 |
3.237 |
| |
566 |
0.747 |
| 24 |
850 |
1.992 |
| |
1133 |
3.237 |
| |
755 |
1.494 |
| 32 |
1133 |
2.490 |
| |
1510 |
3.237 |
| |
991 |
1.743 |
| 42 |
1487 |
2.988 |
| |
1982 |
4.233 |