 Trane Company (The)  Single & Dual Duct VAV Terminal Units  

Single & Dual Duct VAV Terminal Units - Page 32

 

 

Performance Data   VCWE Hot Water Unit Heat

Table P-27- Size 17 (Metric)

STANDARD CAPACITY HIGH CAPACITY
Air flow L/s L/s LAT (C) WTD (C) Coil Cap (kW) WPD (kPa) L/s LAT (C) WTD (C) Coil Cap (kW) WPD (kPa)

118

0.06

52.1

22.1

5.7

2.31

0.19

62.8

9.4

7.3

0.87

 

0.13

58.4

12.9

6.6

8.38

0.50

68.8

3.9

8.1

6.36

 

0.25

62.4

7.0

7.2

31.79

0.82

70.4

2.5

8.4

16.76

 

0.32

63.3

5.7

7.4

49.13

1.26

71.4

1.7

8.5

38.73

165

0.06

45.3

25.6

6.6

2.31

0.19

56.6

11.6

8.9

0.87

 

0.13

51.8

15.4

7.9

8.38

0.50

64.3

4.6

10.5

8.09

 

0.25

56.0

8.6

8.8

31.79

0.82

66.2

2.8

10.9

21.96

 

0.32

57.0

7.0

9.0

49.13

1.26

67.0

2.2

11.0

39.02

212

0.06

40.5

28.1

7.3

2.31

0.19

51.9

13.2

10.2

0.87

 

0.13

46.9

17.3

8.9

8.38

0.50

59.5

5.9

12.2

6.36

 

0.25

51.3

9.8

10.1

31.79

0.82

62.2

3.6

12.9

19.36

 

0.32

52.3

8.1

10.3

49.13

1.26

63.3

2.6

13.2

39.02

260

0.06

37.0

29.9

7.7

2.31

0.19

48.1

14.6

11.3

0.87

 

0.13

43.2

18.8

9.7

8.38

0.50

56.1

6.7

13.9

6.36

 

0.25

47.5

10.8

11.1

31.79

0.82

58.6

4.4

14.7

16.76

 

0.32

48.5

8.9

11.4

49.13

1.26

60.2

2.9

15.2

39.02

307

0.06

34.3

31.4

8.1

2.31

0.19

45.0

15.7

12.2

0.87

 

0.13

40.2

20.1

10.4

8.38

0.50

53.2

7.4

15.3

6.36

 

0.25

44.4

11.6

12.0

31.79

0.82

55.8

4.9

16.3

16.76

 

0.32

45.5

9.6

12.4

49.13

1.26

57.5

3.3

16.9

39.02

354

0.06

32.2

32.6

8.4

2.31

0.19

42.5

16.8

13.0

0.87

 

0.13

37.8

21.1

10.9

8.38

0.50

50.8

8.1

16.6

6.36

 

0.25

42.0

12.3

12.7

31.79

0.82

53.6

5.3

17.8

16.76

 

0.32

43.0

10.2

13.2

49.13

1.26

55.3

3.6

18.6

39.02

401

0.06

30.4

33.7

8.7

2.31

0.19

40.5

17.7

13.7

0.87

 

0.13

35.8

22.1

11.4

8.38

0.50

48.9

8.7

17.8

6.36

 

0.25

39.9

13.0

13.4

31.79

0.82

51.7

5.8

19.3

16.76

 

0.32

40.9

10.8

13.9

49.13

1.26

53.6

3.9

20.2

39.02

472

0.06

28.4

34.9

9.1

2.31

0.19

37.9

18.9

14.7

0.87

 

0.13

33.4

23.2

12.0

8.38

0.50

46.4

9.5

19.5

6.36

 

0.25

37.3

13.8

14.3

31.79

0.82

49.3

6.3

21.2

16.76

 

0.32

38.3

11.6

14.9

49.13

1.26

51.3

4.3

22.4

39.02

519

0.06

27.2

35.7

9.3

2.31

0.19

36.6

19.6

15.2

0.87

 

0.13

32.1

23.9

12.4

8.38

0.50

44.9

10.0

20.6

6.36

 

0.25

35.9

14.3

14.8

31.79

0.82

47.9

6.7

22.5

16.76

 

0.32

36.9

11.9

15.4

49.13

1.26

49.9

4.6

23.8

39.02

614

0.06

25.4

36.9

9.6

2.31

0.19

34.1

20.8

16.1

0.87

 

0.13

29.9

25.1

13.0

8.38

0.50

42.4

10.9

22.4

6.36

 

0.25

33.6

15.2

15.7

31.79

0.82

45.5

7.4

24.7

16.76

 

0.32

34.4

12.7

16.4

49.79

1.26

47.6

5.1

26.3

39.02

708

0.06

24.1

37.9

9.8

2.31

0.19

32.2

21.8

16.9

0.87

 

0.13

28.2

26.1

13.5

8.38

0.50

40.3

11.7

24.0

6.36

 

0.25

31.7

16.0

16.5

31.79

0.82

43.4

8.0

26.7

16.76

 

0.32

32.6

13.4

17.2

49.79

1.26

46.6

5.6

28.6

39.02

802

0.06

22.9

38.8

10.0

2.31

0.19

30.6

22.7

17.6

0.87

 

0.13

26.8

26.9

13.9

8.38

0.50

38.6

12.3

25.5

6.36

 

0.25

30.1

16.6

17.1

31.79

0.82

41.7

8.6

28.5

16.76

 

0.32

30.9

13.9

18.0

49.42

1.26

43.8

6.0

30.7

39.02

Notes :

1. Coils air pressure drop is included in static pressure requirement charts.

2. Coils are leak tested at 31.3 kPa air pressure under water.

3. Capacities based on 82.2º C entering air temperature, 12.8º C degrees entering air temperature, and 0.00025 fouling factor. See capacity correction factors for different entering temperatures.

4. The following equations may be used in calculating Leaving Air Temperature (LAT) and Water Temperature Difference (WTD) :

LAT = EAT + (KW x 824.6 / Airflow L/s)

WTD = EWT - LWT = (MBH x .244 /L/s)

Table  P-28- Temperature Correction Factor for Water Pressure Drop (WPD)

Average Water Temperature (C) 93 88 82 77 71 66 60 54 49 43 38
Correction Factor 0.97 0.985 1.0 1.015 1.030 1.050 1.075 1.100 1.125 1.150 1.180

Note :

1. Multiply water pressure drop from Hot Water Coil Capacity Table by correction factor to get water pressure drop at various entering air and water temperatures.

Table P-29—Temperature Difference Correction Factors

Entering Water Minus Entering Air (F) 25 31 36 42 47 53 58 64 69 75 81
Correction Factor 0.34 0.42 0.50 0.58 0.67 0.75 0.83 0.92 1.00 1.08 1.16

Note :

1. Multiply KW from Hot Water Coil Capacity Table by correction factor to get KW at various entering air and water temperatures.

Request for Information / Request a Catalog from Trane Company (The)
 
 
 
To request more information from Trane Company (The), please complete the form below.
 
*Name:    
*Email:    
Company:    
*Company type:    
Phone:    
*Address:    
*Request:    
    (* = Mandatory field) 
Please add me to the mailing list for the free monthly e-Newsletter AECnews.  
     






Printable version Bookmark this page Notify a colleague or friend about this pageHome | Terms of Use | Privacy Statement | Link to AECinfo.com
AECinfo is a member of Docu Group, the world's largest building products information network.



Copyright © 1996–2010 AECinfo.com