TRUEBRO LAV Guard LAV Guard Page - 2

UNDERSINK PROTECTIVE PIPE COVERS
INSTRUCTIONS
Models 100, 101, 102, 103, & 105
Tools Required:
- Ruler
- Tin sheers
- Small screwdriver
- Needle nose pliers
|
NOTE:
This kit is universally designed for tubular & cast brass P-traps.
Will not fit Schedule 40 Plastic or 2" P-traps.
This kit should only be installed after waste piping and water
piping have been tested for leaks. |
|

|
STEP 1:
Tear P-trap cover on both tear lines to make 3 pieces: J-bend, Waste Arm and Tail Piece.
NOTE:
When installing kit on P-traps with large diameters, simply
cut out internal ribs where necessary for good fit. |
|

|
STEP 2:
Install J-Bend cover directly onto P-trap. Install 3 clips (See Snap-Clip instructions at right). Only trim
J-Bend cover down if there is large compression nut interference.
Example: some tubular plastic traps. |

|
STEP 3:
Trim Waste Arm cover "W" to meet escution flange. IMPORTANT: To ensure a square cut, follow
calibrated trim lines located on inside of cover. Install all Snap-Clips and snap off all clip tails.
NOTE:
If Offset Wheelchair Strainer exists, SKIP STEP 4; refer to
Accessory #105 Instructions A & B on reverse side. |
STEP 4:
Trim Tail Piece cover "T" to meet underside of basin. IMPORTANT: To ensure a square cut, follow
calibrated trim lines located on inside of cover. Also trim around pop-up if needed. Install all
Snap-Clips and snap off all clip tails.
|

|
STEP 5: (Models 101, 102 & 103)
Cut to length both supply tube and valve body ends to allow proper fit. Install all clips including latch.
Snap off all clip tails.
NOTE:
To access angle stop valve, first release latch clip. Then
firmly pull up on access lid to expose valve handle. To
secure, simply close lid & reinstall clip. |
|