| Search |
|
|
|
| |
| Site Navigation |
|
|
|
| News / Publications |
|
|
|
| Jobs | |
|
|
| Service |
|
|
|
|
|


|
| |
|
| |
Wheatland Tube Co. Wheatland Tube Company Wheatland Tube Company - Page 5
Common Pipe Specifications
| Specification and Size Range Where Indicated |
Scope |
Type |
Grades |
Bend Test |
| A 53 1/8" - 26" |
- Black and galvanized welded and SMLS pipe suitable for
welding and forming operations
- CW not intended for flanging.
- Grade B not intended for close coiling or severe cold
forming.
- Pipe required for close coiling should be specified on
order.
|
CW-Type F ERW-Type E
SMLS-Type S |
CW Grade A
ERW & SMLS
grades A & B |
Yes over 2" nominal XHY 90º to 12 times nominal diameter close coiling 180º to 8 times nominal
diameter |
| A 589 Type II 2" - 4"
Type III 2"- 4" |
Type II
Water Well
Reamed & Drifted Type III
Driven Well Pipe |
Type II
SMLS, ERW or CW Type III SMLS,ERW or CW |
Type II
A or CW Type III A or CW |
None Specified |
| API 5L |
Welded and SMLS Line Pipe |
CW-Type F ERW-Type E SMLS-Type S |
CW Grade 25 ERW & SMLS Grades A & B |
Yes for A 25 pipe 2 3/8"
& smaller |
| A 795 NPS 1/2"-10" |
Intended for
use in fire protection systems |
CW-Type F ERW-Type E SMLS-Type S |
CW Grade A Grades A & B |
None specified |
| A 135 NPS 3/4"-5" |
Intended for conveying liquid,
gas or vapor |
ERW-type E |
Grades A & B |
None specified |
| Specification and Size Range Where Indicated |
Chemistry |
Tensiles |
Hydrostatic |
| A 53
1/8" - 26" |
Ladle and Check %
MAX
| Type |
C |
MN |
P |
S |
F
E &S |
|
|
|
|
| Gr. A Gr. B |
.25 .30 |
.95 1.20 |
.05 .05 |
.045 .045 |
|
Minimum P.S.I
| Grade |
Yield |
Tensile |
| F
Gr.A Gr.B |
30,000 30,000
35,000 |
48,000 48,000
60,000 |
|
Yes |
| A 589 Type II
2" - 4"
Type III 2"- 4" |
%MAX |
Minimum
P.S.I.
| Grade |
Yield |
Tensile |
| CW Gr.
A Gr. B |
30,000 30,000
35,000 |
48,000 48,000
60,000 |
|
Yes |
| API 5L |
Ladle % MAX
| Grade |
C |
MN |
P |
S |
| A25 SMLS |
.21 |
.60 |
.08 |
.06 |
| A B |
.22 .27 |
.90 1.15 |
.04 .04 |
.05 .05 |
| ERW A B |
.21.26 |
.901.15 |
.04.04 |
.05.05 |
|
Minimum P.S.I
| Grade |
Yield |
Tensile |
| A 25 Gr.A Gr.B |
25,000 30,000
35,000 |
45,000 48,000
60,000 |
|
Yes |
| A 795 NPS
½"-10" |
%MAX
| Type |
C |
MN |
P |
S |
| F
E & S |
|
|
.05 |
.045 |
| Gr.A Gr.B |
.25 .30 |
.95 1.20 |
.035 .035 |
.035 .035 |
|
|
Yes |
| A 135 NPS ¾"-5" |
| Type |
C |
MN |
P |
S |
| Gr.A Gr.B |
.25 .30 |
.95 1.20 |
.035 .035 |
.035 .035 |
|
Minimum P.S.I
| Grade |
Yield |
Tensile |
| Gr. A Gr. B |
30,000 35,000 |
48,000 60,000 |
|
Yes |
| Specification and Size Range Where Indicated |
Flattening |
Wall Tolerance |
O.D. Tolerance |
| A 53
1/8" - 26" |
Yes - over 2"'
nominal XHY & lighter CW 90° to 75% OD |
Minimum wall at any
point should not be more than 12.5% under Nominal wall. |
½" through1
½" ±1/64" 2" and over ±1% of
OD |
| A 589 Type II
2" - 4"
Type III 2"- 4" |
None
Specified |
Minimum
wall at any point should not be more than 12.5% under nominal wall. |
1
½" and under 2" & over ±1% of
OD |
| API 5L |
Yes |
2 7/8" &
smaller +20% - 12.5% 3 ½" through
18" +15% - 12.5% |
1.900" &
under +.016" -.031 CW 2 3/8" through
4" OD ± 1% OD
2 3/8" through 20" OD ± .75% |
| A 795 NPS
½"-10" |
Yes |
Minimum
wall at any point should not be more than 12.5% under Nominal wall. |
½"
through 1 ½" + 1/64" - 1/32" 2"
& over ± 1% of OD |
| A 135 NPS ¾"-5" |
Yes |
Minimum wall at any
point should not be more than 12.5% under Nominal wall. |
OD shall not vary
more than ± 1% from the Nominal size specified. |
 |
Wheatland TUBE COMPANY |
|