   Willamette  StrucJoist SJ-15-25-35  

StrucJoist - Page 4

 

 

TABLE III DESIGN PROPERTIES
Joist Series Joist
Depth (inches)
Joist wt. Ibs/ft Allow-
able
Moment (ft-lbs)
Max. Shear & End
Reaction
For 4"
Long Bearing
Max. End Reaction

For 1-3/4" Bearing

Max. Interm-
ediate
Reaction (lbs)
Nail Only

El (x 106)

Glue-
Nailed

El (x 106)

K (x 106)
No Web Stiffeners With Web Stiffe-
ners(7)
SJ-15 9-1/2" 1.90 2770 1125 975 1950 2440 176 199 4.94
11-7/8" 2.10 3710 1425 975 1950 2440 304 340 6.18
SJ-25 9-1/2" 2.11 3260 1125 1060 2120 2570 204 227 4.94
11-7/8" 2.37 4360 1425 1060 2120 2570 350 387 6.18
14" 2.60 5360 1550 1060 2120 2570 520 570 7.28
16" 2.82 6300 1550 1060 2120 2570 716 781 8.32
SJ-35 11-7/8" 2.90 5810 1425 1250 2500 2950 452 489 6.18
14" 3.07 7130 1550 1250 2500 2950 667 718 7.28
16" 3.25 8390 1550 1250 2500 2950 913 979 8.32

Notes:

  1. Design properties are based on 2.2E StrucLam LVL flanges.
  2. Glue-nailed El values are for 12" oc spacing and increase for wider joist spacing. Glue-nailed El values apply to floor use only.
  3. Both bending and shear deformations shall be considered when computing deflections. For bending deflection, use standard engineering formulae. For shear deflection use 8x bending moment/K.
    EXAMPLE: Uniformly distributed load on a simple span joist.
    Deflection = 5wl4/384EI + 8M/K = 5wl4/384EI + wl2 /K
    w = uniform load in pounds per linear inch
    I = effective span in inches
  4. The allowable moment, shear and reactions are for normal duration loading and can be increased in accordance with the code for load duration.
  5. Moment values shown are for non-repetitive use. For joist spacing of 24" o.c. or less, values may be increased 4%.
  6. 1-3/4" minimum bearing required at joist ends. 3-1/2" minimum bearing required at intermediate supports.
  7. Option - 5-1/4" bearing without web stiffeners.
  8. Design properties limited to untreated, dry conditions of use and assume lateral support full length of the compression flange.

TABLE IV

Duct Hole Chart Maximum duct hole length

Joist

Series

Joist

Depth

JOIST SPACING (in. o.c.)
12 16 19.2 24
SJ-15 All Depths 12" 8" 6" 6"
SJ-25 9-1/2" & 11-7/8" 13" 9" 8" 8"
14" & 16" 9" 8" 8" 8"
SJ-35 All Depths 15" 12" 10" 8"

Notes:

  1. Do not cut or damage flanges.
  2. Duct holes must be located at center of span.
  3. Duct hole is only allowed in longest span of multiple span joists.
  4. This table is valid for residential spans that meet the floor span tables in this product guide.
  5. Other holes are not allowed within three times the duct hole length.
  6. Allowable depth of hole is depth of web minus 1/4".
  7. Do not over cut corners of holes.

TABLE V

ROUND HOLE CHART Minimum distance from face of nearest support to center of hole.
JOIST HOLE DIAMETER
SERIES DEPTH 3" 4" 5" 6" 6-1/4" 7" 8" 8-5/8" 9" 10" 10-3/4" 12" 12-3/4"
SJ-15 9-1/2"

11-7/8"

2'-0"

1'-0"

3'-0"

1'-6"

4'-6"

2'-6"

6'-0"

4'-0"

6'-6"

4'-6"

5'-6" 7'-6" 8'-6"          
SJ-25 9-1/2"

11-7/8"

14"

16"

3'-0"

1'-0"

1'-0"

1'-0"

4'-0"

2'-0"

1'-0"

1'-0"

5'-0"

3'-6"

2'-0"

1'-6"

6'-6"

5'-0"

3'-6"

3'-0"

7'-0"

5'-6"

4'-0"

3'-6"

6'-6"

5'-0"

4'-6"

8'-6"

7'-0"

6'-0"

10'-0"

8'-0"

7'-0"

 

8'-6"

8'-0"

 

10'-0"

9'-6"

 

12'-0"

10'-6"

 

 

13'-0"

 

 

15'-0"

SJ-35 11-7/8"

14"

16"

3'-0"

1'-0"

1'-6"

4'-0"

2'-0"

3'-0"

5'-6"

3'-6"

4'-0"

7'-0"

5'-0"

5'-6"

7'-0"

5'-6"

6'-0"

8'-6"

7'-0"

7'-0"

10'-6"

8'-6"

8'-6"

11'-6"

9'-6"

9'-6"

10'-6"

10'-0"

12'-6"

11'-6"

14'-0"

12'-6"

 

15'-6"

 

17'-0"

Notes:

  1. Do not cut or damage flanges.
  2. The clear distance between holes must equal or exceed twice the diameter of the largest hole, or three times the longest side of a rectangular hole.
  3. Except as noted in 1 and 2 above, a 2" diameter hole is permitted to be drilled anywhere.
  4. The longest side of a rectangular hole shall not exceed three-fourths of the allowable round hole diameter.
  5. This table is applicable only for uniformly loaded StrucJoist designed using the roof and floor span tables in this Installation Guide. Contact Willamette Industries for other applications.

Request for Information / Request a Catalog from Willamette
 
 
 
To request more information from Willamette, please complete the form below.
 
*Name:    
*Email:    
Company:    
*Company type:    
Phone:    
*Address:    
*Request:    
    (* = Mandatory field) 
Please add me to the mailing list for the free monthly e-Newsletter AECnews.  
     






Printable version Bookmark this page Notify a colleague or friend about this pageHome | Terms of Use | Privacy Statement | Link to AECinfo
AECinfo is a member of Docu Group, the world's largest building products information network.



Copyright © 1996–2008 AECinfo.com