   Willamette  StrucJoist SJ-15-25-35  

StrucJoist - Page 5

 

 

StrucJoist I-Joist Are a Part of Willamette Industries' E-Z Frame ® System

 

TABLE VI
StrucJoist Floor Load Table
Allowable Load in Pounds per Lineal Foot
Joist

Span

(ft)

SJ -15 SJ - 25 SJ -35
9 1/2" 11 7/8" 9 1/2" 11 7/8" 14" 16" 11 7/8" 14" 16"
Live

Load

Total

Load

Live

Load

Total

Load

Live

Load

Total

Load

Live

Load

Total

Load

Live

Load

Total

Load

Live

Load

Total

Load

Live

Load

Total

Load

Live

Load

Total

Load

Live

Load

Total

Load

6   251   251   273   273   273   273   322   322   322
7   216   216    235   235   235   235   277   277   277
8   190   190   206   206   206   206   243   243   243
9   169   169   184   184   184   184   217   217   217
10   153   153   166   166   166   166   196   196   196
11 120 139   139 137 151   151   151   151   178   178   178
12 95 128   128 108 139   139   139   139   164   164   164
13 76 118   118 87 128   128   128   128   151   151   151
14 62 110 104 110 71 119 118 119   119   119   141    141   141
15 51 99 86 102 59 111 98 111   111   111 122 131   131   131
16 43 85 72 96 49 98 82 105   105   105 102 123   123   123
17 36 72 61 91 41 83 69 98   98   98 87 116   116   116
18 31 61 52 86 35 70 59 93 86 93   93 74 110 107 110   110
19 26 52 44 81 30 60 51 88 74 88   88 64 104 92 104   104
20     38 75 26 52 44 84 64 84   84 55 99 80 99   99
21     33 67     38 76 56 80 76 80 48 94 70 94 94   94
22     29 58     33 67 49 76 66 76 42 85 61 90 83 90
23     26 51     29 59 43 73 59 73 37 75 54 86 73 86
24             26 52 38 70 52 70 33 66 48 83 65 83
26                 30 61 41 65 26 53 38 76 52 76
28                 25 49 33 60     31 62 42 71

Notes:

  1. Total load values are based on joists spaced 24" o.c. or less, with increased moment capacity for repetitive member usage. No increase is taken for composite action of glued and nailed sheathing. Table values are for single joist use only, double joists should be evaluated using design properties.
  2. Live load values are based on limiting live load deflection to L/480 and total load deflection to L/240. If live load is not shown, then total load is equal to or exceeds L/480.
  3. Both Live Load and Total Load must be checked to properly size StrucJoist for use in a floor.
  4. Spans are clear distance between supports.
  5. Allowable loads shown may be used for simple or multiple spans. Outermost spans in multiple span applications must be at least 40% of adjacent spans.
Please see the SJ-15 SJ-25 SJ-35 Installation Guide for additional information.

Request for Information / Request a Catalog from Willamette
 
 
 
To request more information from Willamette, please complete the form below.
 
*Name:    
*Email:    
Company:    
*Company type:    
Phone:    
*Address:    
*Request:    
    (* = Mandatory field) 
Please add me to the mailing list for the free monthly e-Newsletter AECnews.  
     






Printable version Bookmark this page Notify a colleague or friend about this pageHome | Terms of Use | Privacy Statement | Link to AECinfo
AECinfo is a member of Docu Group, the world's largest building products information network.



Copyright © 1996–2008 AECinfo.com