Willamette StrucJoist SJ-15-25-35 StrucJoist - Page 9
| TABLE
I |
Design
Properties |
| Joist Series |
Joist Depth
(inches) |
Allowable Moment
(ft-lbs) |
Max. Shear &
End Reaction For 4" Long Bearing |
Max. End Reaction
For 1 3/4" Bearing |
Max. Intermediate
Reaction (lbs) |
Nail Only El (x 106) |
Glue-Nailed El (x 106) |
K (x106)
|
| No Web Stiffeners |
With Web Stiffeners(6)
|
| SJ-150
|
9-1/2" |
2770 |
1125 |
975 |
1950 |
2440 |
164 |
196 |
4.94 |
| 11-7/8"
|
3710 |
1425 |
975 |
1950 |
2440 |
283 |
332 |
6.18 |
| SJ-250 |
9-1/2" |
3260 |
1125 |
1060 |
2120 |
2570 |
190 |
222 |
4.94 |
| 11-7/8" |
4360 |
1425 |
1060 |
2120 |
2570 |
326 |
376 |
6.18 |
| 14" |
5360 |
15506
|
1060 |
2120 |
2570 |
485 |
554 |
7.28 |
| 16" |
6300 |
15506 |
1060 |
2120 |
2570 |
667 |
757 |
8.32 |
| SJ-350
|
11-7/8" |
5050 |
1425 |
1250 |
2500 |
2950 |
407 |
459 |
6.18 |
| 14" |
6200 |
1550 |
1250 |
2500 |
2950 |
600 |
671 |
7.28 |
| 16" |
7300 |
1550 |
1250 |
2500 |
2950 |
822 |
914 |
8.32 |
| SJ-550 |
11-7/8" |
7750 |
1750 |
1400 |
3375 |
3850 |
606 |
660 |
7.18 |
| 14" |
9530 |
1750 |
1400 |
3375 |
3850 |
888 |
962 |
8.47 |
| 16" |
11200 |
1750 |
1400 |
3375 |
3850 |
1209 |
1305 |
9.68 |
Notes:
- Glue-nailed El values are for 12" oc spacing and
increase for wider joist spacing. Glue-nailed El values apply to floor use only.
- Both bending and shear deformations shall be considered when
computing deflections. For bending deflection, use standard engineering formulae.
For shear deflection use 8x bending moment/K.
EXAMPLE: Uniformly distributed load on a simple span joist.
Deflection - 5wt4/384EI + 8M/K = 5wl4/384EI + wl2/K
w = uniform load in pounds per lineal inch
I = effective span in inches
- The allowable moment, shear and reactions are for normal
duration loading and can be increased in accordance with the code for load duration.
- Moment values shown are for non-repetitive use. For joist
spacing of 24" o.c. or less, values may be increased 4%.
- 1-3/4" minimum bearing required at joist ends.
3-1/2" minimum bearing required at intermediate supports.
- Option - 5-1/4" bearing without web stiffeners.
- Design properties limited to untreated, dry conditions of
use and assume lateral support full length of the compression flange.


| TABLE II |
| Duct Hole Chart
Maximum duct hole length |
| Joist Series |
Joist Depth |
JOIST
SPACING (in.o.c.) |
| 12 |
16 |
19.2 |
24 |
| SJ-150 |
All Depths |
12" |
8" |
6" |
6" |
| SJ-250 |
9 -1/2" &
11-7/8" |
13" |
9" |
8" |
8" |
| 14" & 16" |
9" |
8" |
8" |
8" |
| SJ-350 |
All Depths |
12" |
10" |
10" |
10" |
| SJ-550 |
All Depths |
12" |
10" |
8" |
8" |
Notes:
- Do not cut or damage flanges. Do not overcut corners of
holes.
- Full depth rectangular holes shall be located at center of
span.
- A full depth rectangular hole is only allowed in longest
span of multiple span joists.
- This table is valid for residential spans that meet the
floor span tables in this product guide. Contact Willamette Industries for other
applications.
- Other holes are not allowed within three times the duct hole
length specified in table.
- Allowable depth of hole is depth of web minus 1/4".
| TABLE III |
| ROUND HOLE CHART
Minimum distance from face of nearest support to center of hole. |
| JOIST |
HOLE
DIAMETER |
| SERIES |
DEPTH |
3" |
4" |
5" |
6" |
6-1/4" |
7" |
8" |
8-5/8" |
9" |
10" |
10-3/4" |
12" |
12-3/4" |
| SJ-150 |
9-1/2" 11-7/8" |
2'-6" 1'-6" |
3'-6" 2'-6" |
4'-6" 3'-6" |
5'-6" 4'-6" |
6'-0" 4'-6" |
5'-6" |
6'-6" |
8'-0" |
|
|
|
|
|
| SJ-250 |
9-1/2" 11-7/8"
14" 16" |
3'-0" 2'-0"
1'-0"
1'-0" |
4'-0" 3'-0"
1'-0"
1'-0" |
5'-0" 4'-0"
2'-0"
1'-0" |
6'-6" 5'-0"
3'-6"
1'-0" |
7'-0" 5'-6"
4'-0"
1'-0" |
6'-6" 4'-6"
2'-6" |
8'-0" 6'-0"
5'-0" |
9'-6" 7'-0"
5'-0" |
7'-6"
5'-6" |
9'-0"
7'-0" |
11 '-6"
8'-0" |
10'-6" |
13'-0" |
| SJ-350 |
11-7/8" 14"
16" |
3'-6" 1'-6"
1'-0" |
4'-6" 3'-0"
1'-0" |
5'-6" 4'-0"
1'-6" |
7'-0" 5'-6"
3'-0" |
7'-6" 6'-0"
3'-6" |
8'-6" 6'-6"
5'-0" |
10'-0" 8'-0"
6'-6" |
11'-6" 9'-0"
7'-6" |
10'-0" 8'-0" |
11'-6" 9'-6" |
13'-6" 11 '-0" |
13'-6" |
15'-0" |
| SJ-550 |
11-7/8" 14"
16" |
2'-6" 2'-0"
1'-0" |
4'-6" 3'-6"
1'-0" |
6'-0" 4'-6"
2'-0" |
7'-6" 6'-0"
3'-6" |
8'-0" 6'-6"
4'-0" |
9'-6" 8'-0"
5'-6" |
11'-0" 10'-0"
7'-0" |
12'-6" 11'-0"
8'-6" |
11'-6" 9'-0" |
13'-6" 11'-6" |
15'-6" 13'-0" |
16'-0" |
18'-0" |
Notes:
- Do not cut or damage flanges.
- The clear distance between holes must equal or exceed twice
the diameter of the largest hole, or three times the longest side of a rectangular hole.
- Except as noted in A and B above, a 2" diameter hole is
permitted to be drilled anywhere.
- The longest side of a rectangular hole shall not exceed
three-fourths of the allowable round hole diameter.
- This table is applicable only for uniformly loaded
StrucJoist designed using the roof and floor span tables in this Product Guide. Contact
Willamette Industries for other applications.
- Outermost spans of multiple span applications shall be at
least 40% of the adjacent span.
|