   Willamette  Wood Construction Connectors  

Wood Construction Connectors - Page 12

 

 

           
               ®
UFP UNIVERSAL FOUNDATION PLATE

CONCRETE

 

The UFP10 Retrofit Foundation Plate cuts installation time in half. Designed to connect when the mudsill is offset from the foundation up to 2-1/2" or extended beyond the foundation up to 1/2".

The UFP may be used in place of the FA, HFA and FAP connectors.

MATERIAL: 14 gauge

FINISH: Galvanized

INSTALLATION:

  • Use all specified fasteners; see General Notes.
  • Loads are based on Simpson's SDSX3 screw's allowable shear values, which are supplied with the UFP10.
  • Alternate lag screws will not achieve published loads.
  • See Epoxy-Tie™ Anchoring Systems and RFB Retrofit Bolt for tested, load-rated epoxies and retrofit bolts.

CODES: ICBO 5313; City of L.A. RR 25281.

Model No. Max. Spacing to replace Anchor Bolt 1/2" or 5/8" dia. Fasteners Allowable Load Parallel to Plate (133)
Anchor Bolt Plate
Qty Dia
UFP10 6" 2 1/2" 5-SDS1/4x3 1340

 

 

 

1. Allowable loads have been increased 33% for earthquake or wind loading, with no further increase allowed. Reduce where other load durations apply.

2. The retrofit bolt RFB#4X7 with Epoxy-Tie embedded 4-1/4" or equivalent 1/2" x 4-1/4" mechanical anchor bolt embedded 2-1/4" may be used for the anchoring system.

3. Each anchor bolt requires a standard cut washer.


GLB/HGLB/GLBT BEAM SEATS



                                                                     GLBT

 

FINISH: Simpson gray paint

INSTALLATION:

  • Use all specified fasteners. See General Notes.
  • Bolt holes shall be a minimum of 1/32" to a maximum of 1/16" larger than the bolt diameter (per the 1997 NDS, section 8.1.2.1.).
  • Check the rebar spacing requirements on all installations.

OPTIONS:

  • Sawn timber and other sizes may be ordered by specifying special dimensions; use the letter designations shown on the illustrations.
  • Specify if two-bolt GLB model is desired: see illustration.

CODES: ICBO 1211, City of L.A. RR 22086.

Model No. Dimensions Bolts Allowable Bearing Loads (100)
W PD PW PT Qty Dia Masonry @ 188 psi Masonry @ 375 psi Concrete1
GLB5A 5-1/4 5 7 3 ga 1 1/2 4935 9845 11530
GLB5B 5-1/4 6 7 3/8 1 1/2 5920 11810 13840
GLB5C 5-1/4 7 7 3/8 1 1/2 6910 13780 16145
GLB5D 5-1/4 8 7 3/8 1 1/2 7900 15750 18450
GLB7A 6-7/8 5 9 3ga 1 3/4 6460 12890 15190
GLB7B 6-7/8 6 9 3/8 1 3/4 7755 15470 18225
GLB7C 6-7/8 7 9 3/8 1 3/4 9050 18045 21260
GLB7D 6-7/8 8 9 3/8 1 3/4 10340 20625 24300

 

 

 

 

 

 

 

1. Allowable concrete bearing values are based on the allowable bearing of the wood member on the steel plate at 450 psi.

Model No. Dimensions Bolts Allowable Bearing Loads Allowable Horizontal Bolt Loads3,4
W PD PW PT Qty Dia Masonry @ 188 psi1 Masonry @ 375 psi1 On Concrete With Glulam Width2 (133) (160)
5-1/8 6-3/4 8-3/4 10-3/4
HGLBB SPEC 5 10 3/8 2 3/4 9400 18750 11530 15190 19690 -- 8260 9910
HGLBB SPEC 6 10 3/8 2 3/4 11280 22500 13835 18225 23625 -- 8260 9910
HGLBG SPEC 7 10 3/8 2 3/4 13160 26250 16140 21260 27560 -- 8260 9910
HGLBD SPEC 8 10 3/8 2 3/4 15040 30000 18450 24300 31500 -- 8260 9910
GLBT512 SPEC 5-1/4 12 5/16 2 3/4 11845 23625 12110 15945 20670 25395 8260 9910
GLBT612 SPEC 6-1/2 12 3/8 2 3/4 14665 29250 14990 19745 25595 31445 8260 9910
GLBT516 SPEC 5-1/4 16 5/16 2 3/4 15790 31500 12110 15945 20670 25395 8260 9910
GLBT616 SPEC 6-1/2 16 3/8 2 3/4 19550 39000 14990 19745 25595 31445 8260 9910
GLBT520 SPEC 5-1/4 20 5/16 2 3/4 19740 39375 12110 15945 20670 25395 8260 9910
GLBT620 SPEC 6-1/2 20 3/8 2 3/4 24440 48750 14990 19745 25595 31445 8260 9910

 

 

 

 

 

 

 

 

1. 1.Allowable masonry bearing loads must be reduced where limited by the wood bearing on the plate.

2. Allowable concrete bearing loads are limited by the allowable bearing of the wood at 450 psi. Loads must be adjusted for other widths not shown.

3. The GLBT5 has a WT4x9 structural tee; the GLBT6 has a WT4x12 structural tee.

4.Allowable horizontal bolt loads include a 33% and 60% increase for earthquake or wind loading; reduce if masonry or concrete is limiting.

Request for Information / Request a Catalog from Willamette
 
 
 
To request more information from Willamette, please complete the form below.
 
*Name:    
*Email:    
Company:    
*Company type:    
Phone:    
*Address:    
*Request:    
    (* = Mandatory field) 
Please add me to the mailing list for the free monthly e-Newsletter AECnews.  
     






Printable version Bookmark this page Notify a colleague or friend about this pageHome | Terms of Use | Privacy Statement | Link to AECinfo
AECinfo is a member of Docu Group, the world's largest building products information network.



Copyright © 1996–2008 AECinfo.com