STRONG-WALL™

 

STANDARD WALL DATA

Model Set Up W (In) H (in) T (in) Number of Fasteners In Top of Wall Number of Mudsill Anchors Holdown Anchor Bolt
SW24x8-4 24 93-1/4 3-1/2 12-SDS1/4X6 2-5/8 SSTB28
SW32x8-4 32 93-1/4 3-1/2 16-SDS1/4x6 2-5/8 SSTB28
SW48x8-4 48 93-1/4 3-1/2 24-SDS1/4x6 3-5/8 SSTB28
SW24x9-4 24 105-1/4 3-1/2 12-SDS1/4x6 2-5/8 SSTB28
SW32x9-4 32 105-1/4 3-1/2 16-SDS1/4x6 2-5/8 SSTB28
SW48x9-4 48 105-1/4 3-1/2 24-SDS1/4x6 3-5/8 SSTB28
SW32x10-4 32 117-1/4 3-1/2 16-SDS1/4x6 2-5/8 SSTB28
SW48x10-4 48 117-1/4 3-1/2 24-SDS1/4X6 3-5/8 SSTB28

 

Model Set Up Allowable Shear V Load (lb) Drift at Allowable Shear V (in) Allowable Shear V Load (lb/ft) Assembled Wall Weight (lbs)
SW24x8-4 1610 .389 804 91
SW32x8-4 2875 .545 1078 116
SW48x8-4 4545 .380 1136 149
SW24x9-4 1585 .396 793 101
SW32x9-4 2600 .427 975 128
SW48x9-4 4370 .439 1093 165
SW32x10-4 2460 .453 923 134
SW48x10-4 4095 .435 1024 171
  1. For plywood shear panel, add "P" to model name (e.g. SW24x8-4P), and multiply the table loads by 0.88.
  2. For two-pour applications, use the SSTB34.

GARAGE PORTAL DATA

Model Set Up W (in) H (in) T (in) Number of Fasteners in Top of Wall Number of Mudsill Anchors Holdown Anchor Bolt4
SW16x7-4 16 78 4 8-SDS1/4x6 2-5/8 STHD14SW
SW22x7-4 22 78 4 12-SDS1/4x6 2-5/8 SSTB28
SW22x7-6 22 78 6 12-SDS1/4x6 2-5/8 SSTB28

 

Model Set Up Allowable Shear V Load (lb) for Portal System3 Drift at Allowable Shear V (in) Allowable Shear V Load (lb/ft) Assembled Wall Weight (lbs)
SW16x7-4 3020 .346 1133 71
SW22x7-4 4820 .369 1315 95
SW22x7-6 4820 .369 1315 117
  1. For plywood shear panel, add "P" to model name (e.g. SW24x8-4P), and multiply the table loads by 0.88.
  2. For two-pour applications, use the SSTB34.
  3. A portal system consists of 2 return walls with a header spanning over the top and connected as shown.
  4. STHD14SW requires a minimum 12" grade beam.

STRONG-WALL CONCRETE TEMPLATE

Model1 No. Corresponding Strong-Wall Length (in)
SWT16 SW16x7-4 16
SWT22 SW22x7-4 22
SWT22-6 SW22x7-6 22
SWT24, SWTI24 SW24x8-4, SW24x9-4 24
SWT32, SWTI32 SW32x8-4, SW32x9-4, SW32x10-4 32
SWT48, SWTI48 SW48x8-4, SW48x9-4, SW48x10-4 48

 

 

 

 

  1. SWT1 models are for interior shearwall applications


Factory-built Strong-Wall requires no
special tools for installation


SWT Strong-Wall Template

Request for Information / Request a Catalog from Willamette
 
 
 
To request more information from Willamette, please complete the form below.
 
*Name:    
*Email:    
Company:    
*Company type:    
Phone:    
*Address:    
*Request:    
    (* = Mandatory field) 
Please add me to the mailing list for the free monthly e-Newsletter AECnews.  
     






Printable version Bookmark this page Notify a colleague or friend about this pageHome | Terms of Use | Privacy Statement | Link to AECinfo
AECinfo is a member of Docu Group, the world's largest building products information network.



Copyright © 1996–2008 AECinfo.com