PA/PAHD/HPAHD HOLDOWNS
|
Wood-to-concrete connectors that satisfy engineering and code
requirements.
MATERIAL: HPA -- 10 gauge x 2-1/16"; all
others -- 12 gauge x 2-1/16"
FINISH: Galvanized. Selected products available in
Z-MAX coating; see page 6.
INSTALLATION:
- Use all specified fasteners. See General Notes.
- Bending the strap 90° to aid wall placement may cause spalling
behind the strap. If the spall is 1" or less, measured from the top of the concrete
foundation to the bottom of the spall, full loads apply. For spalls between 1" and
4" (see illustration), the allowable load is 0.90 of the table loads.
- Where fewer fasteners are used in the structural wood member, reduce
loads according to the code. A wood splitting problem may occur when holdowns are nailed
to lumber less than 3-1/2" wide. To lessen splitting of 3x's or double 2x's, either
fill every nail hole with 10dx1-1/2" nails or fill every other nail hole with 16d
commons. Reduce the allowable load based on the size and quantity of fasteners used.
- Unless otherwise noted, do NOT install where: (a) a horizontal cold
joint exists within the embedment depth between the slab and foundation wall or
footing beneath, unless provisions are made to transfer the load, or the slab is
designed to resist the load imposed by the anchor; or (b) slabs are poured over concrete
block foundation walls.
- To get the full table load, the minimum center-to-center spacing is
twice the embedment depth when resisting tension loads at the same time.
FOUNDATION CORNERS:
Nail and bolt quantities have been reduced when the load is limited
by tested concrete pullout strength (fill holes from bottom up); additional nail holes
need not be filled. Nail and bolt quantities may be reduced further for less than 8"
corner distance design loads -- use code allowable loads for fasteners used in shear.
TWO-POUR SYSTEMS: When a cold joint exists between
slab and foundation, the holdown will be lower on the stud wall since the embedded portion
of the holdown must be in the foundation (see table footnote 1 for exception). Fewer
fasteners are used, reducing allowable loads. Loads are calculated using a 4" slab
over 6" and 8" foundation walls.
PA51, PA68 FOUNDATION STRAPS: Designed for
foundation to double 2x10 band joists and crawl space floor system connections in high
wind or earthquake resistant construction.
PAHD42, HPAHD22, HPAHD22-2P HOLDOWNS: Designed to
be installed at the edge of concrete. Tests determined the pullout strength with one
horizontal #4 rebar in the shear cone. Rebar should be a min. length of 2x embedment depth
+ 12" (except corner installations, pg 19). Install before
pouring concrete by nailing to form. Installation holes allow nailing to the form,
resulting in 1" deeper embedment; see illustration.
OPTIONS: See also HDA Holdowns, LTT, MTT, HTT
Tension Ties.
CODES: BOCA, ICBO, SBCCI NER-393 and NER-469.
| Model
No. |
Min
Stem Width |
Fasteners
|
Avg
Ult |
Allowable
Uplift Loads |
| Nails
|
Bolts
|
(133)
|
(160)
|
| Qty
|
Dia
|
Nails
|
Bolts
|
Nails
|
Bolts
|
| EDGE
INSTALLATION -- 2500 PSI CONCRETE |
| SINGLE
POUR (see installation 1) 8" min from corner |
| PAHD42 |
6 |
12-16d |
3 |
1/2 |
6620 |
2205 |
1855 |
2205 |
2205 |
| 8 |
16-16d |
3 |
1/2 |
9613 |
2945 |
1855 |
2945 |
2225 |
| HPAHD22 |
6 |
16-16d |
4 |
1/2 |
10667 |
3330 |
3245 |
3335 |
3335 |
| 8 |
23-16d |
4 |
1/2 |
16203 |
4570 |
3245 |
5160 |
3895 |
| DOUBLE
POUR (see installation 4) 8" min from corner |
| PAHD442 |
6 |
12-16d |
2 |
1/2 |
6620 |
2205 |
1755 |
2205 |
2105 |
| 8 |
12-16d |
2 |
1/2 |
9613 |
2225 |
1755 |
2705 |
2105 |
| HPAHD22 |
6 |
16-16d |
3 |
1/2 |
10667 |
3330 |
2445 |
3335 |
2935 |
| 8 |
19-16d |
3 |
1/2 |
16203 |
3775 |
2445 |
4530 |
2935 |
| HPAHD22-2P |
6 |
16-16d |
-- |
-- |
10667 |
3180 |
-- |
3335 |
-- |
| 8 |
23-16d |
-- |
-- |
16203 |
4570 |
-- |
5160 |
-- |
| CORNER
INSTALLATION -- 2000 PSI CONCRETE |
| SINGLE
POUR ( see installation 2&3) 1/2" min from corner |
| PAHD42
|
6 |
7-16d |
2 |
1/2 |
3763 |
-- |
-- |
-- |
-- |
| 8 |
8-16d |
2 |
1/2 |
4345 |
1050 |
1050 |
1050 |
1050 |
| HPAHD22 |
6 |
7-16d9 |
-- |
-- |
5610 |
1315 |
-- |
1315 |
-- |
| 9-16d |
3 |
1/2 |
5610 |
1315 |
1315 |
1315 |
1315 |
| 8 |
10-16d9 |
-- |
-- |
7452 |
2030 |
2030 |
2030 |
2030 |
| DOUBLE
POUR ( see installation 5) 1/2" min from corner |
| PAHD42
|
6 |
7-16d |
2 |
1/2 |
3763 |
920 |
920 |
920 |
920 |
| 8 |
8-16d |
2 |
1/2 |
4345 |
1050 |
1050 |
1050 |
1050 |
| HPAHD22 |
6 |
9-16d |
3 |
1/2 |
5610 |
1315 |
1315 |
1315 |
1315 |
| 8 |
11-16d |
3 |
1/2 |
7452 |
2030 |
2030 |
2030 |
2030 |
| HPAHD22-2P
|
6 |
12-16d |
-- |
-- |
7452 |
2030 |
-- |
2030 |
-- |
| 8 |
12-16d |
-- |
-- |
7452 |
2030 |
-- |
2030 |
-- |
- HPAHD22 may be embedded 4" into the slab and 6" into the
8" stemwall beneath for a maximum load of 2810 lbs. at 8" minimum from the
closest corner, and 1200 Ibs. at 1/2" from the closest corner (like installation 4).
- TYPICAL INSTALLATION: The minimum concrete compression strength is
2500 psi. For 2000 psi, calculate loads at 0.89 of the table allowable loads. CORNER
INSTALLATION: The minimum concrete compression strength is 2000 psi.
- Allowable loads have been increased 33% and 60% for earthquake or
wind loading with no further increase allowed.
- 16d sinkers (9 ga x 3-1/4') or 10d commons may be substituted for
specified 16d commons at 0.85 of table loads.
- Minimum nail end distance to prevent splitting is 10x the nail
diameter, or 1-5/8" for 16d nails,
- Calculate loads using straight line interpolation for corner
distances between 1/2" and 8".
- Minimum lumber thickness for bolt allow able loads is 2-1/2" for
proper embedment of bolt into the wood member; reduce allowable load according to the code
for lesser lumber thicknesses.
- Optional fastener holes are provided on selected
products. Because the product is limited by the concrete foundation,
you may not need to install optional fasteners.
- Rim joist application; see Installation 3 for corner condition.
- Strap may be bent one full cycle.
| Model
No. |
L
|
Min.
Embed. Depth |
Nails
|
Allowable
Uplift Loads |
| (133) |
(160) |
| PA51 |
51 |
4 |
9-16d |
1690 |
2030 |
| PA68 |
70 |
4 |
9-16d |
1690 |
2030 |
- Loads have been increased 33% and 60% for earthquake or wind loading
with no further increase allowed.
- 16d sinkers (9 GA x 3-1/4") or 10d commons may
be substituted for the specified 16d commons at 0.85 of the table
loads.
- Optional fastener holes provided. Calculate loads
according to the code to a maximum of 3685 IBS Minimum embedment is
4"; 5" to the nearest edge.
|